• TD3550  Single-Phase Energy Meters test bench
  • TD3550  Single-Phase Energy Meters test bench
  • TD3550  Single-Phase Energy Meters test bench
  • TD3550  Single-Phase Energy Meters test bench
  • TD3550  Single-Phase Energy Meters test bench
  • TD3550  Single-Phase Energy Meters test bench

TD3550  Single-Phase Energy Meters test bench

After-sales Service: Life Time
Warranty: 12 Months Excellent After Service
Application: Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD3550  Single-Phase Energy Meters test bench pictures & photos
TD3550  Single-Phase Energy Meters test bench
US $35,000-60,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD3550
Power
Electricity
Voltage Output
max 264V
Current Output
max 120A
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
Class 0.05/Class 0.1
Harmonic output
2nd~63rd
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
150.00cm * 85.00cm * 85.00cm
Package Gross Weight
80.000kg

Product Description

TD3550 Single-phase Energy Meters Verification Device
TD3550 Single-Phase Energy Meters test bench
 

1. Summary

TD3550 is a new type of energy meter verification device used to verify that it meets the OIML R46 instruction. It mainly consists of single-phase precision standard power source, verification platform, measurement and control platform, PC(optional) and verification software. TD3550 supports simultaneous verification of 6 ~ 24 single-phase electricity/mechanical energy meters, smart meters and IOT electricity meter, etc. with the same voltage/current range, different meter constant.
 

2. Features

2.1 Basic Features

  1. Maximum output capacity: 264 V / 120 A.
  2. Fundamental frequency: 45 Hz ~ 100 Hz.
  3. Accuracy: class 0.05 or 0.1.
  4. Minimum current output: As low as 1 mA.
  5. Auto range: Automatic range switching and load matching.
  6. Energy measurement: Positive / negative active and reactive energy.
  7. Harmonic output: 2nd~63st @50Hz / 60Hz, harmonic content and phase are adjustable.
  8. High order harmonic test: Built in high-order harmonic test schemes.
  9. Complex waveform test: Built in common waveform scheme, like square-wave, cusp wave, sub-harmonics and odd-harmonic, etc.
  10. DC and even harmonics test: Equipped with TD3410 half wave rectifier box.
  11. Daily reckoning error test: Built in standard clock tester.
  12. Automatic patrol inspection: Support automatic patrol inspection.
  13. Connection: Equipped with special pressure gauge holder.
  14. Communication: RS-485, pulse and photoelectric sampling port.
  15. Multiple-position verification: Optional 6,12,16,24 positions.
  16. Mobile control unit: LCD touch screen for value output.
  17. Professional verification software: Support semi-automatic or fully automatic verification of the DUT / UUT, data management and certificate export. The software has the function of single point multiple tests, the test interval can be set, and the error curve can be drawn automatically.
 

2.2 Optional Features

  1. Voltage/ Current line power consumption test: The voltage/ current line power consumption test can be completed by selecting the voltage power consumption test module.
  2. Burden current fast change test: The user can set the duration of ton and toff, and the total time for a single test. The current switches at zero crossing and switches off and on within one nominal frequency period. The repetition time of single test was more than 4 hours.
  3. AC Voltage dips and interruptions test: AC Voltage dips and interruptions test supporting voltage circuit power supply.
  4. Standard meter: Optional conventional class 0.5 standard meter or harmonic standard meter.
  5. Harmonic energy: Complete harmonic energy accuracy test and measurement accuracy test by selecting harmonic standard meter.
 

3. Verification Items

NO. Verification Items Completion
(standard)
Remarks
1 Observation, Mark, Power on inspection Observation items  
2 Accuracy Test Initial intrinsic error test  
3 Starting current test  
4 Test of no-load  
5 Constant test  
6 Combined error of energy indication value of electronic indicator display  
7 Clock error test powered by power supply  
8 Clock error test using standby power supply  
9 Error consistency test  
10 Variation requirement test  
11 Load current rise and fall  
12 Repeat test  
13 Electromagnetic Test Voltage dips and interruptions Optional-Fast change test of load current  
14 Resistance to Other Influences Harmonics in voltage and current -5th harmonic test  
15 Harmonics in voltage and current -Square wave test  
16 Harmonics in voltage and current -Cusp wave test  
17 Sub-harmonics in the AC current circuit -Pulse train trigger waveform test  
18 Odd harmonics in current circuit - 90°phase trigger wave test  
19 DC and even harmonics - half-wave rectification waveform test  
20 Voltage variation test  
21 Frequency variation test  
22 Fast change test of load current test Optional-
Fast change test of load current
 
23 Self-heating test  
24 High order harmonic test  
25 Electrical Performance Test Voltage line power consumption test Optional -
 Voltage line power consumption test
 
26 Current line power consumption test Optional - 
Current line power consumption test
 
27 IOT Electricity Meter Harmonic power accuracy test Optional - Harmonic energy  
28 Harmonic measurement accuracy test  
 

4. Specifications

4.1 Voltage Output

Range Resolution Short-term Stability
 ( % / min )
Accuracy
±(ppm of reading + ppm of range) [1]
Distortion Factor
( % )
Class 0.05 Class 0.1 Class 0.05 Class 0.1
220 V 1 mV 0.01 0.02 200 + 50 300 + 200 < 0.3
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
  1. Output range: 0 V ~ 264 V, 6-digits display, load capacity: 15VA/ (phase · position)
  2. Protective function: Short-circuit protection, Overload protection
 

4.2 Current Output

Range Resolution Short-term Stability
 ( % / min )
Accuracy
±(ppm of reading + ppm of range) 
Distortion Factor
( % )
Class 0.05 Class 0.1 Class 0.05 Class 0.1
10 mA 0.1 μA 0.02 0.04 300 + 200 500 + 300 < 0.5
20 mA 0.1 μA 0.02 0.04 300 + 200 500 + 300 < 0.5
50 mA 0.1 μA 0.02 0.04 200 + 50 300 + 200 < 0.5
100 mA 1 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
200 mA 1 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
500 mA 1 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
1 A 10 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
2 A 10 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
5 A 10 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
10 A 100 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
20 A 100 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
50 A 100 μA 0.01 0.02 200 + 50 300 + 200 < 0.5
100 A 1 mA 0.01 0.02 200 + 50 300 + 200 < 0.5
  1. Output range: 1 mA~120 A, 6-digits display, load capacity: 30VA/ (phase · position)
  2. Protective function: Open-circuit protection, Overload protection

4.3 Frequency / Phase

Accuracy Class 0.05 Class 0.1
Frequency Measuring Range 45 Hz~100 Hz 45 Hz~100 Hz
Minimum Resolution 0.000 01 Hz 0.000 01 Hz
Accuracy ±0.005%*RD ±0.005%*RD
Phase
(I ≥ 50mA)
Measuring Range 0~360° 0~360°
Minimum Resolution 0.000 1° 0.000 1°
Accuracy ±0.012° ±0.024°
 

4.4 Power/ Energy

Current Range Power Factor Accuracy ±(% of reading)
Class 0.05 Class 0.1
50 mA ≤ I ≤120 A 0.5L~1~0.5C 0.05%*RD 0.1%*RD
10 mA ≤ I < 50 mA 1 0.05%*RD 0.1%*RD
0.5L~1~0.5C 0.08%*RD 0.15%*RD
1 mA ≤ I < 10 mA 1 0.08%*RD 0.15%*RD
0.5L~1~0.5C 0.15%*RD 0.3%*RD
  1. Stability of output power: 0.02% / 2min (Class 0.05),0.05% / 2min (Class 0.1);
  2. Measuring range of P/E: Combination of AC voltage and AC current range  ;
  3. Measuring range of power factor: -1.000 00…0.000 00…1.000 00;
  4. Standard electric energy pulse output: High frequency pulse output port outputs 60KHz at full range, low frequency pulse output port outputs 6Hz at full range;
  5. Standard electric energy pulse input: frequency ≤ 200 kHz, voltage:0…3.3 V…24 V;
  6. Electric energy error display: Auto, resolution is 0.0001%.

4.5 Clock

  1. Daily reckoning error limit: ±0.05 s/d

5. General Specifications

Power supply Single phase AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
Warm up time 30min
Temperature performance Operating temperature: 5°C~45°C;
Storage temperature: -10°C~55°C
Humidity performance Operating humidity: < 80% @ 30°C,< 70% @ 40°C, < 40% @ 50°C;
Storage humidity: (20%~80%) R·H, no condensation.
Communication interface RS232, RS485, LAN
Dimensions of test bench
(L*W *table H / total H, mm)
Position number 6 positions 12 positions 16 positions 24 positions
Manual wiring 1350*750*750/1415 -- -- --
Crimp wiring 1350*750*750/1415 1240*750*600/1782 1590*750*600/1782 2290*750*600/1782
Dimensions of computer desk
(L*W*H, mm)
No standard meter 1000*800*750
Standard meter 1500*800*750
 

6. Ordering Information

TD3550 Single-Phase Energy Meters test bench
Special Customized Function Selection Table
Tick Option function Description
  Manual wiring The default option is Crimping wiring (with meter rack) , Manual wiring is optional.
  Voltage line power consumption test Recommend one position
  Current line power consumption test At most three position are recommended
  Load current rise and fall After this function is selected, all positions support;
Support voltage dip and short interruption at the same time.
  Standard meter TD3100 standard meter (Class 0.05/0.1)
  Harmonic energy TD3100-R standard meter (Class 0.05/ 0.1)

Company Profile
 

TD3550 Single-Phase Energy Meters test bench

TD3550 Single-Phase Energy Meters test benchTD3550 Single-Phase Energy Meters test bench

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD3550  Single-Phase Energy Meters test bench pictures & photos
TD3550  Single-Phase Energy Meters test bench
US $35,000-60,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013