• TH0690 Current Transducer Integrated Measurement Analyzer
  • TH0690 Current Transducer Integrated Measurement Analyzer
  • TH0690 Current Transducer Integrated Measurement Analyzer
  • TH0690 Current Transducer Integrated Measurement Analyzer
  • TH0690 Current Transducer Integrated Measurement Analyzer

TH0690 Current Transducer Integrated Measurement Analyzer

After-sales Service: Life Time
Warranty: 12 Months Excellent After-Sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TH0690 Current Transducer Integrated Measurement Analyzer pictures & photos
TH0690 Current Transducer Integrated Measurement Analyzer
US $77,600 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TH0690
Power
Electricity
LCD Display
With LCD Display
Customized
Non-Customized
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
50.00cm * 50.00cm * 40.00cm
Package Gross Weight
20.000kg

Product Description

 
TH0690 Current Transducer Integrated Measurement Analyzer
TH0690 Current Transducer Integrated Measurement Analyzer

 

1. Summary

TH0690 is an intelligent instrument dedicated to the comprehensive performance evaluation of current transducers. It can accurately test the electrical characteristics such as ratio error (k) and phase displacement (δ) of I/I and I/V current transformers, and can also measure the AC magnetic characteristics of the transformer core. It solves the problem of complex calculation of the relationship between magnetic properties and electrical properties in the process of transducers design, and provides the most complete means for the analysis and measurement of current transformers.
 

2. Feature

  1. AC Power Output/Measurement Accuracy: Class 0.005
  2. Working Frequency Range: 45 Hz~65 Hz.
  3. Support multi-frequency point measurement of ratio error (k) and phase displacement (δ)
  4. Draw frequency or current characteristic curve with the software.
  5. Support various magnetic characteristic parameter measurement and curve drawing.
  6. With automatic demagnetization function, it can evaluate the magnetic resistance of the transformer.
  7. Special Test Software (optional)

3. Application

  1. Current transformer ratio error (k) and phase displacement (δ) calibration.
  1.  Magnetic performance testing of finished transformers and semi-finished iron cores.
  2.  Current transformer quality inspection, design verification, iron core pairing.
  3.  Ratio error (k) and phase displacement (δ) measurement of the current measurement circuit.
  1. Anti-magnetic evaluation of current transformers.
☆ Current transformer ratio error and phase displacement calibration.
TH0690 Current Transducer Integrated Measurement Analyzer
  1. Measure and calibrate the ratio error and phase displacement of the current transformer.
  2. Draw the frequency characteristic curve k(F),δ(F),current characteristic curve k(I),δ(I).
 
☆ Measuring the magnetic properties of core semi-finished products.
TH0690 Current Transducer Integrated Measurement Analyzer
  1. It can measure the magnetic properties of finished transformers and semi-finished iron cores.
  2. Parameter Measurement: μi,μm,Hc,Br,Bs,μa,Bm,Hm,δ etc.

4. specifications

4.1 ACI Output/ I1

Current Range Short-term Stability
(%/min)
Measurement Uncertainty
(k=2, ppm*RD+ppm*RG)1
Maximum Load Voltage(V) Distortion
(%)
24 h
(23±1)°C
90 days
(23±5)°C
1 year
(23±5)°C
2 mA 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
5 mA 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
10 mA 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
20 mA 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
50 mA 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
100 mA 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
200 mA 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
500 mA 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
1 A 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
2 A 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
5 A 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
10 A 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
20 A 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
50 A 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
100 A 0.003 20 + 20 25 + 20 30 + 20 1.2 < 0.2
Note: 1 RD is the reading value, RG is the range value, the same below.
  1. ACI Output:200 μA~120 A,7-digit display.
  2. Frequency range: 45 Hz~65 Hz; Adjustment Fineness: 0.0001 Hz; Measurement Uncertainty: 0.001 Hz
  3. Protection Function: short circuit protection, overload protection.

4.2 ACV Measurement /U2 and ACI Measurement/I2

AC Range Resolution Measurement Uncertainty
(k=2, ppm*RD +ppm*RG)
24 h
(23±1)°C
90 days
(23±5)°C
1 year
(23±5)°C
ACV/U2 20 mV 10 nV 40 + 40 50 + 40 60 + 40
50 mV 10 nV 20 + 20 25 + 20 30 + 20
100 mV 100 nV 20 + 20 25 + 20 30 + 20
200 mV 100 nV 20 + 20 25 + 20 30 + 20
500 mV 100 nV 20 + 20 25 + 20 30 + 20
1 V 1 μV 20 + 20 25 + 20 30 + 20
2 V 1 μV 20 + 20 25 + 20 30 + 20
5 V 1 μV 20 + 20 25 + 20 30 + 20
ACI/I2 200 μA 0.1 nA 20 + 20 25 + 20 30 + 20
500 μA 0.1 nA 20 + 20 25 + 20 30 + 20
1 mA 1 nA 20 + 20 25 + 20 30 + 20
2 mA 1 nA 20 + 20 25 + 20 30 + 20
5 mA 1 nA 20 + 20 25 + 20 30 + 20
10 mA 10 nA 20 + 20 25 + 20 30 + 20
20 mA 10 nA 20 + 20 25 + 20 30 + 20
50 mA 10 nA 20 + 20 25 + 20 30 + 20
100 mA 100 nA 20 + 20 25 + 20 30 + 20
  1. U2 Measurement Range: 2 mV~5.5 V,7-digit display.
  2. I2 Measurement Range: 20 μA~110 mA,7-digit display.
  3. Harmonic Measurement: 2nd to 63rd.

4.3 Ratio Error (k) and Phase Displacement (δ) Measurement

Ratio Error Measurement Range Current transformer input current like I1
Current transformer output current like I2
Measurement Uncertainty
(k=2)
0.01% @ 45 Hz ~ 65 Hz
Phase Displacement Measurement Range 0.000°~359.999°
Measurement Uncertainty
(k=2)
0.001° @ 45 Hz~65 Hz
 

4.4 Measurement of Magnetic Parameters of Current Transformer Iron Core

Measured Parameters Measurement Uncertainty
(k=2)
Measurement Repeatability
μi 1.5% 4.0%
μm 1.0% 2.0%
Hc 0.5% 1.0%
Br 0.3% 1.0%
Bs 0.3% 1.0%
μa 1.0% 3.0%
Bm 0.5% 1.0%
Hm 1.0% 2.0%
δ 1.5% 5.0%
Hc 1.0% 3.0%
Br 1.0% 3.0%
μ' 1.0% 3.0%
μ′′ 1.0% 3.0%
μL 1.0% 3.0%
Note: The iron core should be demagnetized before the test, and the parameters of the iron core should be input as required. The measurement temperature T: (23±5)°C.

Company Profile
 

TH0690 Current Transducer Integrated Measurement Analyzer

TH0690 Current Transducer Integrated Measurement AnalyzerTH0690 Current Transducer Integrated Measurement Analyzer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TH0690 Current Transducer Integrated Measurement Analyzer pictures & photos
TH0690 Current Transducer Integrated Measurement Analyzer
US $77,600 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013