• TD2100 Verification Apparatus for DC Shunts
  • TD2100 Verification Apparatus for DC Shunts
  • TD2100 Verification Apparatus for DC Shunts
  • TD2100 Verification Apparatus for DC Shunts
  • TD2100 Verification Apparatus for DC Shunts
  • TD2100 Verification Apparatus for DC Shunts

TD2100 Verification Apparatus for DC Shunts

After-sales Service: Life Time
Warranty: 12 Months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD2100 Verification Apparatus for DC Shunts pictures & photos
TD2100 Verification Apparatus for DC Shunts
US $35,800-49,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD2100
Power
Electricity
Customized
Non-Customized
Accuracy
Class 0.02/Class 0.05
DC standard current
0.5 A ~ 600 A
Precision DC voltage measurement
100 μV~ 11 V
Resistance measurement range
200 nΩ~6 Ω
Units position of DC shunt
3/6
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
200.00cm * 150.00cm * 150.00cm
Package Gross Weight
90.000kg

Product Description

TD2100 Verification Apparatus for DC Shunts
TD2100 Verification Apparatus for DC Shunts
1. Summary
TD2100 is a device specially used to test DC shunt. It adopts modular design and is composed of multi meter position verification platform, DC high current standard source, precision DC voltmeter, multi-function measurement and control unit, verification software, etc. It can be widely used in all levels of measurement departments and power departments to verify various DC diverters for measurement, and it is also suitable for manufacturers to quickly inspect products.

2. Features
Accuracy: class 0.02/0.05
DC standard current: 0.5 A ~ 600 A
Precision DC voltage measurement: 100 μV~ 11 V
Resistance measurement range: 200 nΩ~6 Ω
3/6/12 meter positions DC shunt calibration table can be selected.
Constant current source mode is adopted for measurement.
Shunts manual/automatic crimping device is optional.
Measure the resistance value and basic error of the shunt, and draw R (I) and R (t) curves.
Optional temperature measurement function, recording the highest temperature point and thermal balance time of the shunt.
Professional test software (option)

 
3. Main Applications
Verification of DC Shunt
TD2100 Verification Apparatus for DC Shunts
  1. DC Standard High Current Source: The maximum output is 600 A, which can be used as the primary current input of DC shunt.
  2. Precision DC voltage measurement: The support voltage input range is 100 μ V~11V, used to measure the secondary output voltage of the shunt.
  3. Verification and test of DC shunt: the resistance value and basic error of the shunt can be measured, and R (I) and R (t) curves can be drawn.

4. Functional Features

High Accuracy and Stability of Current Output
TD2100 Verification Apparatus for DC Shunts
  1. Precise integrated circuit devices are used to ensure the long-term accuracy of the system.
  2. Adopt the design principle of closed-loop negative feedback system to ensure the stability of output.
 
Manual Crimping Device (Option)
TD2100 Verification Apparatus for DC Shunts
Manual crimping device (option): Manually press the current terminal of the shunt to be tested, and connect it with the current source to form a current loop; With precise DC voltage measurement function, it can complete the verification of DC shunt;
 
Automatic Crimping Device (Option)
TD2100 Verification Apparatus for DC Shunts
Automatic crimping device (option): Automatically press the current terminal of the shunt to be tested, and connect it with the current source to form a current loop; With precise DC voltage measurement function, it can complete the verification of DC shunt;
 
Professional Test Software
TD2100 Verification Apparatus for DC Shunts
With RS232 communication interface, software functions can be customized according to customer needs


5. Specifications

5.1 DC current output DCI

Range Short-term Stability (% / min) Accuracy
( ± ppm of reading + ppm of range) [1]
Maximum load (V)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
5 A 0.005 0.003 120 + 80 60 + 40 4
10 A 0.005 0.003 120 + 80 60 + 40 4
20 A 0.005 0.003 120 + 80 60 + 40 4
50 A 0.005 0.003 120 + 80 60 + 40 4
100 A 0.005 0.003 120 + 80 60 + 40 4
200 A 0.005 0.003 120 + 80 60 + 40 4
500 A 0.005 0.003 120 + 80 60 + 40 4
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
  1. Output range: 0.5A~600 A, Ripple coefficient: < 0.1 %
  2. 7-digits display, Regulating fineness: 0.001%*RG
  3. Protection function: Open circuit protection, Overload protection
 

5.2 DC voltage measurement  

Range Accuracy
( ± ppm of reading + ppm of range)
Temperature coefficient @ (15~30) °C
(ppm*RG/°C)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
1 mV 150 + 1 80 + 0.5 <30 <15
10 mV 150 + 3 80 + 1.5 <10 <5
100 mV 150 + 10 80 + 5 <10 <5
1 V 150 + 20 80 + 10 <5 <2
10 V 150 + 100 80 + 50 <5 <2
  1. Measuring range: ± (100 μV~11 V), Manual/automatic range switching, 7-digits display
  2. Input resistance: >1 GΩ, Input protection: 50 Vpk, continuously

5.3 DC resistance measurement

Test current Voltage range Measuring range of resistance Accuracy
@ Full scale voltage value
0.05 0.02
5 A (0.1~1) mV 20 μΩ ≤ R ≤ 200 μΩ 0.135% 0.068%
(1~10) mV 200 μΩ < R ≤ 2 mΩ 0.065% 0.033%
(10~100) mV 2 mΩ < R ≤ 20 mΩ 0.045% 0.023%
(0.1~1) V 20 mΩ < R ≤ 200 mΩ 0.037% 0.019%
(1~3) V 200 mΩ < R ≤600 mΩ 0.036% 0.019%
10 A (0.1~1) mV 10 μΩ ≤ R ≤ 100 μΩ 0.135% 0.068%
(1~10) mV 100 μΩ < R ≤ 1 mΩ 0.065% 0.033%
(10~100) mV 1 mΩ < R ≤ 10 mΩ 0.045% 0.023%
(0.1~1) V 10 mΩ < R ≤ 100 mΩ 0.037% 0.019%
(1~3) V 100 mΩ < R ≤300 mΩ 0.036% 0.019%
20 A (0.1~1) mV 5 μΩ ≤ R ≤ 50 μΩ 0.135% 0.068%
(1~10) mV 50 μΩ < R ≤ 500 μΩ 0.065% 0.033%
(10~100) mV 500 μΩ < R ≤ 5 mΩ 0.045% 0.023%
(0.1~1) V 5 mΩ < R ≤ 50 mΩ 0.037% 0.019%
(1~3) V 50 mΩ < R ≤ 150 mΩ 0.036% 0.019%
50 A (0.1~1) mV 2 μΩ ≤ R ≤ 20 μΩ 0.135% 0.068%
(1~10) mV 20 μΩ < R ≤ 200 μΩ 0.065% 0.033%
(10~100) mV 200 μΩ < R ≤ 2 mΩ 0.045% 0.023%
(0.1~1) V 2 mΩ < R ≤ 20 mΩ 0.037% 0.019%
(1~3) V 20 mΩ < R ≤ 60 mΩ 0.036% 0.019%
100 A (0.1~1) mV 1 μΩ ≤ R ≤ 10 μΩ 0.135% 0.068%
(1~10) mV 10 μΩ < R ≤ 100 μΩ 0.065% 0.033%
(10~100) mV 100 μΩ < R ≤ 1 mΩ 0.045% 0.023%
(0.1~1) V 1 mΩ < R ≤ 10 mΩ 0.037% 0.019%
(1~3) V 10 mΩ < R ≤ 30 mΩ 0.036% 0.019%
200 A (0.1~1) mV 500 nΩ ≤ R ≤ 5 μΩ 0.135% 0.068%
(1~10) mV 5 μΩ < R ≤ 50 μΩ 0.065% 0.033%
(10~100) mV 50 μΩ < R ≤ 500 μΩ 0.045% 0.023%
(0.1~1) V 500 μΩ < R ≤ 5 mΩ 0.037% 0.019%
(1~3) V 5 mΩ< R ≤ 15 mΩ 0.036% 0.019%
500 A (0.1~1) mV 200 nΩ ≤ R ≤ 2 μΩ 0.135% 0.068%
(1~10) mV 2 μΩ < R ≤ 20 μΩ 0.065% 0.033%
(10~100) mV 20 μΩ < R ≤ 200 μΩ 0.045% 0.023%
(0.1~1) V 200 μΩ < R ≤ 2 mΩ 0.037% 0.019%
(1~3) V 2 mΩ< R ≤ 6 mΩ 0.036% 0.019%
Note : The uncertainty of resistance measurement corresponding to other voltage values=( U/U0+ I/I0), U0 and I0 are the reading values of current voltage and current respectively, U and I are the absolute error values of current measured voltage and current respectively
  1. Measuring range of resistance: 200 nΩ~6 Ω,6- digits display,Minimum resolution: 1 pΩ
  2. The current test point can be set through the number keys, and the voltage range: manual/automatic switching
  3. After loading the test current, the R (t) change curve can be tested

5.4 Multi point continuous temperature measuring device (option)

  1. Temperature measurement type: average temperature of coverage
  2. Resolution of infrared array: 16×4
  3. Temperature measurement range: -50°C~+300°C
  4. Temperature measurement accuracy: ±0.1°C
6. General Specifications
Power supply AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz;
Temperature performance Operating temperature: 15 °C~30 °C;
Storage temperature: -20 °C ~ 70 °C;
Humidity performance Operating humidity: ( 20 % ~ 50% ) R·H, No condensation;
Storage humidity: ( 15 % ~ 80% ) R·H, No condensation;
communication interface RS 232
Unit size 1500 mm (W) × 800 mm (D) × 1210 mm (H) @ 3 Table body
1500 mm (W) × 800 mm (D) × 1250 mm (H) @ 6 Table body
TD2100 Verification Apparatus for DC Shunts

7. Ordering Information

  TD2100 Verification Apparatus for DC Shunts
 
Company Profile
 

TD2100 Verification Apparatus for DC Shunts

TD2100 Verification Apparatus for DC ShuntsTD2100 Verification Apparatus for DC Shunts

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD2100 Verification Apparatus for DC Shunts pictures & photos
TD2100 Verification Apparatus for DC Shunts
US $35,800-49,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013