• TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration
  • TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration
  • TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration
  • TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration
  • TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration
  • TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration

TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration

After-sales Service: Life Time
Warranty: 12 Months Excellent After-Sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Power: Electricity
LCD Display: With LCD Display
Customized: Non-Customized
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Features
  • Application
  • Specifications
  • Company Profile
Overview

Basic Info.

Model NO.
TH2000
Dual Channel Voltage Measurement Range
0.5 Mv ~ 6 V
Frequency Measurement Range
DC, AC 10 Hz ~ 20 kHz
Best Uncertainty of Voltage and Power
50ppm and 100ppm
Best Uncertainty of Phase Displacement
0.0005°
Transport Package
Package for Exporting
Specification
390 mm (W) * 270 mm (D) *180 mm (H), 10Kg
Trademark
TUNKIA
Origin
China
Production Capacity
100 Set/Year

Product Description

TH2000 Vector Voltage Analyzer
 
TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration
Product Description

TH2000 is a high-precision vector voltage analyzer, it can measure the ratio error and phase displacement between two channel voltage. With the function of measuring and analyzing various electrical parameters, such as voltage, current, frequency, phase, harmonic, power, etc., TH2000 is suitable for wideband electrical measurement scenarios.

Features

 

(1) Dual channel voltage measurement range: 0.5 mV ~ 6 V
(2) Frequency measurement range: DC, AC 10 Hz ~ 20 kHz
(3) The best uncertainty of voltage and power are 50ppm and 100ppm
(4) The Best uncertainty of phase displacement is 0.0005°
(5) Supporting dual channel voltage multiplication and division operation
(6) Can measure and analyze the 2nd~256th harmonics
(7) Can display harmonic content, total harmonic distortion and spectrum diagram
(8) Statistical analysis of the measured electrical parameters
(9) Supporting both internal and external synchronization
(10) Supporting battery power supply, to improve CMRR
(11) USB, RS232 and LAN communication interfaces
(12) Equipped with LCD touch screen
 
Application


(1) Measuring wideband voltage
(2) Measuring wideband current
(3) Measuring wideband electrical parameters of dual channel
(4) Building wideband power / electrical energy measurement system
(5) Calibrating wideband power source / meter and power analyzer
(6) Calibrating the ratio error and phase displacement of wideband current transformer / transducer
(7) Calibrating the ratio error and phase displacement of wideband voltage divider / transducer
 

 Measuring Wideband Voltage  
TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration Equipped with wideband voltage divider (such as TH0150) to build a wideband voltage measurement system and calibrate a wideband voltage source / meter.
 
 Measuring Wideband Current
TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration Equipped with coaxial shunt (such as TH0400) to build a wideband current measurement system and calibrate a wideband current source / meter.

 Building Wideband Power / Electrical Energy Measurement System
TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration Equipped with wideband V / V conversion device (such as TH0150) and wideband I / V conversion device (such as TH0400) to build a wideband power / electrical energy measurement system and calibrate a wideband power source / meter and power analyzer.

 Calibrating Wideband Transformer / Transducer
TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration Equipped with wideband current transformer / sensor and coaxial shunt to build a wideband measurement system and calibrate the ratio error and phase displacement of a wideband transformer, transducer or I/V conversion standard.
 
 Calibrating Wideband Voltage Divider/ Transformer  
TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration Equipped with voltage divider to build a wideband measurement system and calibrate the ratio error and phase displacement of a wideband voltage divider, transformer or transducer.
 
Specifications

 

5.1 Wideband voltage measurement

Range Accuracy
± (ppm of reading + ppm of range) [1]@ ( 23 ± 5 )°C
DC 10 ~ 20 20 ~ 40 40 ~ 1 k 1 k ~ 5 k 5 k ~ 20 k
2 mV 500 + 10 300 + 8.0 300 + 5.0 500 + 3.0 600 + 3.0 800 + 3.0
5 mV 300 + 10 200 + 5.0 300 + 3.0 200 + 2.0 250 + 2.0 250 + 2.5
10 mV 100 + 10 250 + 5.0 250 + 2.0 200 + 1.5 250 + 1.5 250 + 2.0
20 mV 80 + 10 200 + 10 200 + 2.0 200 + 1.5 300 + 1.5 300 + 2.0
50 mV 60 + 10 300 + 10 200 + 2.0 150 + 1.8 200 + 1.8 250 + 2.0
100 mV 50 + 15 300 + 15 150 + 2.0 80 + 1.8 120 + 1.8 150 + 2.0
200 mV 50 + 20 300 + 20 120 + 2.0 60 + 1.8 90 + 1.8 120 + 2.0
500 mV 50 + 30 300 + 30 100 + 3.0 50 + 2.5 60 + 2.5 120 + 3.0
1 V 45 + 30 300 + 30 100 + 5.0 45 + 3.5 60 + 3.5 80 + 5.0
2 V 45 + 35 300 + 30 100 + 10 45 + 6 60 + 6 90 + 10
5 V 45 + 50 300 + 50 100 + 20 45 + 15 60 + 15 80 + 20
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
 

5.2 Frequency / Phase Measurement

Frequency Measuring range 10.000 000 Hz~20.000 000 kHz
Minimum resolution 1 μHz
Accuracy 0.005%*RD
Phase Measuring range 000.000 00° ~ 359.999 99°
Minimum resolution 0.000 01°
Accuracy ± 0.001°@45 Hz~1 kHz
± 0.003°@1 kHz~5 kHz
 

5.3 Ratio Error Measurement

Accuracy 45 Hz ~ 1 kHz 60 ppm
1 kHz ~ 5 kHz 100 ppm
Note 0.2 V ~ 6 V, U1 / U2≈1
 

5.4 Energy Pulse

(1) The full-scale value corresponds to 60 kHz when high-frequency pulse is output
(2) The full-scale value corresponds to 6 Hz when low-frequency pulse is output
(3) Energy pulse input: frequency ≤ 10 kHz, voltage: 0 ~ 3.3 V…24 V

6. Ordering Information

  TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration
Note: the specifications of accuracy 20ppm, frequency 100kHz and 1MHz are customized products.

7. General Specifications

Power Supply AC: 195 V ~ 242 V / 47 Hz ~ 63 Hz
Lithium battery (built-in)
Maximum Power Consumption 30 W(under non-charging condition)
Warm-up Time 30 minutes, shall not be less than twice the shutdown time
Operation Environment Temperature: 10 ~ 40°C
Humidity: 20% R·H ~ 85% R·H, non-condensing
Storage Environment Temperature: -20°C~70°C
Humidity: < 95% R·H, non-condensing
Communication Interface RS232×1, LAN×1, USB×1
Screen 8.4 inch color LCD display
Dimensions 390 mm (W) × 270 mm (D) × 180 mm (H), without feets

 
TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration
 
Weight About 10 kg
 
Company Profile

 

TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration
TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration
TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now