TD1540  DC Shunt Calibration Device

After-sales Service: Life Time
Warranty: 12 Months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD1540  DC Shunt Calibration Device pictures & photos
TD1540  DC Shunt Calibration Device
US $23,800-26,500 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD1540
Power
Electricity
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
Class 0.02 / Class 0.05
DC standard current
1 mA~600 A
Precision DC voltage measurement
10 μV~11 V
Resistance measurement range
200 nΩ~6 Ω
Transport Package
Package for Exporting
Specification
623 mm (W) * 548 mm (D)* 260 mm (H), 49.5Kg
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
80.00cm * 62.00cm * 32.00cm
Package Gross Weight
55.000kg

Product Description

TD1540 DC Shunt Calibration Device

1. Summary
TD1540 is a set of instrument specially used for calibrating DC shunt, which is composed of DC standard large current source and precision DC voltmeter. It can be applied to the verification of DC shunt used for various measurements by metering and power departments at all levels, and also to the quality inspection of products by manufacturers.

2. Features
Accuracy: Class 0.02 / Class 0.05
DC standard current:0.5A~600 A
Precision DC voltage measurement: 100 μV~11 V
Resistance measurement range: 200 nΩ~6 Ω
A variety of quantity output adjustment methods
Measuring the resistance value and basic error of the shunt, drawing R (I) and R (t) curve
Professional test software (option)

3. Applications
 Calibrate High-current DC Meter
TD1540 DC Shunt Calibration Device
  1. The device has a built-in DC current standard source with an output range of 0.5 A~600 A, and the current accuracy of the class 0.02 device reaches class 0.01, which is suitable for calibrating the DC large ammeter of class 0.05 and below.
  2. The device can provide 600 A large current for the primary side of current conversion devices (such as transformer, I/I conversion, I/V conversion, etc.).
 
 Verification of DC Shunt
TD1540 DC Shunt Calibration Device
  1. DC high current standard source: Maximum output is 600 A, which can be used as the primary current input of the DC shunt.
  2. DC small signal voltmeter: Support voltage input range is 100 μV~11 V, which can measure the secondary output voltage of the shunt.
  3. Verification and test of DC shunt (option): Can measure the resistance value and basic error of the diverter, draw R (I) and R (t) curves.
 

4. Functional Features

 High accuracy and stability of current output
TD1540 DC Shunt Calibration Device
Precise integrated circuit devices are used to ensure the long-term accuracy of the system.
Adopt the design principle of closed-loop negative feedback system to ensure the stability of output.
 
 Convenience of Operation
TD1540 DC Shunt Calibration Device
Digital programmable keys: It can realize fixed-point output, rotary encoder, step adjustment and multiple input modes.
 
 Multiple Output Methods
TD1540 DC Shunt Calibration Device
The instrument has a "fixed-point output" mode. The required output value can be directly set by pressing the number keys on the console or clicking the touch screen, and the instrument will automatically switch to the optimal range output;
In particular, when setting the current, input the current value directly.
 
  • Rotary Knob Adjustment Output
TD1540 DC Shunt Calibration Device
The key operation area is equipped with a "rotary knob", which can increase or decrease the value output by rotating clockwise or counterclockwise.
 
 Proportional Output
TD1540 DC Shunt Calibration Device
When calibrating electrical measuring instruments, it is usually necessary to select calibration points according to the proportion of each range of the meter being tested;
The user can select the calibration point of the tested meter through the "percentage verification point" on the touch screen of the instrument.
 
 Professional Test Software (Option)
TD1540 DC Shunt Calibration Device
The device has RS232 communication interfaces, and its software functions can be customized according to customer needs.


5. Specifications

5.1 DC current output DCI

Range Short-term Stability (% / min) Accuracy
( ± ppm of reading + ppm of range) [1]
Maximum load (V)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
5 A 0.005 0.003 120 + 80 60 + 40 3.5
10 A 0.005 0.003 120 + 80 60 + 40 3.5
20 A 0.005 0.003 120 + 80 60 + 40 3.5
50 A 0.005 0.003 120 + 80 60 + 40 3.5
100 A 0.005 0.003 120 + 80 60 + 40 3.5
200 A 0.005 0.003 120 + 80 60 + 40 3.5
500 A 0.005 0.003 120 + 80 60 + 40 3.5
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
  1. Output range:0.5A~600 A, Ripple coefficient: < 0.5 %
  2. 7-digits display, Regulating fineness: 0.001%*RG
  3. Protection function: Open circuit protection, Overload protection

5.2 DC small signal voltage measurement DCV

Range Accuracy
( ± ppm of reading + ppm of range)
Temperature coefficient @ (15~30) °C
(ppm*RG/°C)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
1 mV 150 + 1 80 + 0.5 <30 <15
10 mV 150 + 3 80 + 1.5 <10 <5
100 mV 150 + 10 80 + 5 <10 <5
1 V 150 + 20 80 + 10 <5 <2
10 V 150 + 100 80 + 50 <5 <2
  1. Measuring range: ± (100 μV~11 V), Manual/automatic range switching, 7-digits display
  2. Input resistance: >1 GΩ, Input protection: 50 Vpk, continuously

5.3 DC resistance measurement

Test Current Voltage Range Measuring Range of Resistance Accuracy
@ Full scale voltage value
0.05 0.02
5 A (0.1~1) mV 20 μΩ ≤ R ≤ 200 μΩ 0.135% 0.068%
(1~10) mV 200 μΩ < R ≤ 2 mΩ 0.065% 0.033%
(10~100) mV 2 mΩ < R ≤ 20 mΩ 0.045% 0.023%
(0.1~1) V 20 mΩ < R ≤ 200 mΩ 0.037% 0.019%
(1~3) V 200 mΩ < R ≤600 mΩ 0.036% 0.019%
10 A (0.1~1) mV 10 μΩ ≤ R ≤ 100 μΩ 0.135% 0.068%
(1~10) mV 100 μΩ < R ≤ 1 mΩ 0.065% 0.033%
(10~100) mV 1 mΩ < R ≤ 10 mΩ 0.045% 0.023%
(0.1~1) V 10 mΩ < R ≤ 100 mΩ 0.037% 0.019%
(1~3) V 100 mΩ < R ≤300 mΩ 0.036% 0.019%
20 A (0.1~1) mV 5 μΩ ≤ R ≤ 50 μΩ 0.135% 0.068%
(1~10) mV 50 μΩ < R ≤ 500 μΩ 0.065% 0.033%
(10~100) mV 500 μΩ < R ≤ 5 mΩ 0.045% 0.023%
(0.1~1) V 5 mΩ < R ≤ 50 mΩ 0.037% 0.019%
(1~3) V 50 mΩ < R ≤ 150 mΩ 0.036% 0.019%
50 A (0.1~1) mV 2 μΩ ≤ R ≤ 20 μΩ 0.135% 0.068%
(1~10) mV 20 μΩ < R ≤ 200 μΩ 0.065% 0.033%
(10~100) mV 200 μΩ < R ≤ 2 mΩ 0.045% 0.023%
(0.1~1) V 2 mΩ < R ≤ 20 mΩ 0.037% 0.019%
(1~3) V 20 mΩ < R ≤ 60 mΩ 0.036% 0.019%
100 A (0.1~1) mV 1 μΩ ≤ R ≤ 10 μΩ 0.135% 0.068%
(1~10) mV 10 μΩ < R ≤ 100 μΩ 0.065% 0.033%
(10~100) mV 100 μΩ < R ≤ 1 mΩ 0.045% 0.023%
(0.1~1) V 1 mΩ < R ≤ 10 mΩ 0.037% 0.019%
(1~3) V 10 mΩ < R ≤ 30 mΩ 0.036% 0.019%
200 A (0.1~1) mV 500 nΩ ≤ R ≤ 5 μΩ 0.135% 0.068%
(1~10) mV 5 μΩ < R ≤ 50 μΩ 0.065% 0.033%
(10~100) mV 50 μΩ < R ≤ 500 μΩ 0.045% 0.023%
(0.1~1) V 500 μΩ < R ≤ 5 mΩ 0.037% 0.019%
(1~3) V 5 mΩ< R ≤ 15 mΩ 0.036% 0.019%
500 A (0.1~1) mV 200 nΩ ≤ R ≤ 2 μΩ 0.135% 0.068%
(1~10) mV 2 μΩ < R ≤ 20 μΩ 0.065% 0.033%
(10~100) mV 20 μΩ < R ≤ 200 μΩ 0.045% 0.023%
(0.1~1) V 200 μΩ < R ≤ 2 mΩ 0.037% 0.019%
(1~3) V 2 mΩ< R ≤ 6 mΩ 0.036% 0.019%
  1. Resistance measurement range: 200 nΩ~6 Ω, 6-digits display, Minimum resolution: 1 pΩ
  2. The current test point can be set through the number keys, and the voltage range: manual/automatic switching
  3. After loading the test current, the R (t) change curve can be tested

6. General Specifications
Power supply AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz;
Warm up time 2h;
Maximum power consumption 4.8 kVA
Sampling rate 0.5 sps
Temperature performance Operating temperature: 15 °C~30 °C;
Storage temperature: -20 °C ~ 70 °C;
Humidity performance Operating humidity: ( 20 % ~ 50% ) R·H, No condensation;
Storage humidity: ( 15 % ~ 80% ) R·H, No condensation;
Altitude < 3000 m
Weight About 49.5 kg
Communication interface RS 232
Unit size 623 mm (W) × 548 mm (D) × 260 mm (H) (Excluding handle and support foot)
 

7. Ordering Information

 TD1540 DC Shunt Calibration Device
 
Company Profile
 

TD1540 DC Shunt Calibration Device

TD1540 DC Shunt Calibration DeviceTD1540 DC Shunt Calibration Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD1540  DC Shunt Calibration Device pictures & photos
TD1540  DC Shunt Calibration Device
US $23,800-26,500 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013