• TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
  • TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
  • TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
  • TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
  • TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
  • TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below

TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below

After-sales Service: Life Time
Warranty: 12 Months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below pictures & photos
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
US $15,000-16,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
TD1860
Power
Electricity
Voltage Output
Max. 1100V
Current Output
Max. 22A(33A optional)
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
Class 0.05
DC voltage output
±(10 mV ~ 1100 V)
DC current output
±(3 μA ~ 22 A)(33A optional)
AC voltage output
3 mV ~ 1100 V
AC current output
30 μA ~ 22 A(33A optional)
Sinusoidal wave frequency
45 Hz ~ 1500 Hz
Simulated DC resistance
0 Ω ~ 220 MΩ
Transport Package
Package for Exporting
Specification
450 mm(W)* 505 mm (D)* 203 mm (H), 19.5Kg
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
55.00cm * 60.00cm * 30.00cm
Package Gross Weight
30.000kg

Product Description

TD1860 Multi-function Calibrator
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
 

1. Summary

TD1860 is a multi-function calibrator with wide range and high precision, integrates AC\DC voltage source, AC\DC current source, DC resistance source, etc. The DC accuracy class is up to 0.01, and the AC accuracy class is up to 0.05. It's applied for calibrating 4.5 digits multimeter, voltmeter, ammeter, ohmmeter, power meter.

2. Features

DC voltage output: ±(10 mV ~ 1100 V)
DC current output: ±(3 μA ~ 22 A)(33 A optional)
AC voltage output: 3 mV ~ 1100 V
AC current output: 30 μA ~ 22 A(33 A optional)
Sinusoidal wave frequency: 45 Hz ~ 1500 Hz
Simulated DC resistance:0 Ω ~ 220 MΩ
2 MHz square wave frequency output
Phase output
AC/DC power output
Remote adjustment(optional)
Clamp meter calibration(optional)
Transducer calibration(optional)  

3. Application

TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below

 
 Calibrate AC\DC electrical measuring instruments
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
  1. DCV output: ±(10 mV ~ 1100 V)
  2. DCI outpu: ±(3 μA ~ 22 A or 33 A)
  3. ACV output: 3 mV ~ 1100 V,45 Hz ~ 1500 Hz
  4. ACI output: 30 μA ~ 22 A or 33 A,45 Hz ~ 1500 Hz
  5. RES output: 0 Ω ~ 220 MΩ
  6. Frequency output: 1 Hz ~ 2 MHz
  7. Calibrate digital multimeter, AC/DC voltmeter, AC/DC ammeter, DC ohmmeter, frequency meter.
 Calibrate AC\DC power meters
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
Calibrate DC power meter, real power meter, phantom power meter, apparent power meter, power frequency phase meter and power factor meter.
 
 Calibrate clamp ammeter (optional)
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters.
 Calibrate AC/DC Transducer (optional)
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
DC small-signal measurement. (Vmax: 12 V, Imax: 24 mA)
Calibrate the proportional error of AC/DC voltage/current transducer.

4. Panel Features

 Front\Side Panel
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
Item Description
1 LCD touch screen.
2 Pulse frequency output terminal.
3 Input terminals for transducer.
4 Operation panel.
5 Foldable feets.
6 AC/DC current output terminals.
7 AC/DC voltage output terminals.
8 Simulated DC resistance output terminals.
 
 Rear panel
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
Item Description
1 Remote box interface.
2 RS232 communication interface.
3 Cooling vents.
4 Chassis ground binding post.
5 AC 220V power interface.
6 Foldable feets.
7 Handle: used for carrying instruments.

5. Characteristics

 Wide output range
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
 


 
 Multiple output\adjustment methods
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
"Direct output" mode: the value output can be set directly by physical key or touch screen.
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
Calibration of the analog pointer meter usually needs to test scale by scale, especially "differences between rising and falling" (the change caused by the rise and fall of the calibration point).
Remote box can realize the coarse and fine adjustment of current or voltage.
 

6. Specifications

6.1 DC Voltage Output  

Range Resolution Stability Accuracy[1] Max Burden (mA) Ripple Factor
(%)
24 hours
(23±1)°C
90 days
(23±5)°C
1 year
(23±5)°C
±(ppm*output + μV)
100 mV 1 μV 40 + 5 64 + 10 80 + 10 300 <0.5
300 mV 1 μV 40 + 5 64 + 10 80 + 10 300 <0.5
1 V 10 μV 40 + 10 64 + 15 80 + 15 300 <0.5
3 V 10 μV 40 + 10 64 + 15 80 + 15 300 <0.5
10 V 100 μV 40 + 100 64 + 150 80 + 150 600 <0.5
30 V 100 μV 40 + 150 64 + 150 80 + 150 800 <0.5
100 V 1 mV 40 + 1500 64 + 1500 80 + 1500 300 <0.5
300 V 1 mV 40 + 1500 64 + 1500 80 + 1500 120 <0.5
1000 V 10 mV 40 + 5000 64 + 5000 80 + 5000 40 <0.5
Note[1]:When the output is negative, the floor uncertainly is double. For example, when the output is 1 V, the accuracy is (80 ppm × 1 V + 30 μV);
  1. Output range: ±(10 mV ~ 1100 V)
  2. Short-circuit and overload protection

6.2 DC Current Output

Range Resolution Stability Accuracy [1] Compliance Voltage (V) Ripple Factor (%)
24 hours
(23±1)°C
90 days
(23±5)°C
1 year
(23±5)°C
±(ppm*RD + μA)
30 μA 100 pA 96 + 0.02 108 + 0.02 120 + 0.02 11 <0.5
100 μA 1 nA 96 + 0.04 108 + 0.04 120 + 0.04 11 <0.5
300 μA 1 nA 96 + 0.04 108 + 0.04 120 + 0.04 11 <0.5
1 mA 10 nA 96 + 0.08 108 + 0.08 120 + 0.08 11 <0.5
3 mA 10 nA 96 + 0.08 108 + 0.08 120 + 0.08 11 <0.5
10 mA 100 nA 96 + 0.8 108 + 0.8 120 + 0.8 11 <0.5
30 mA 100 nA 96 + 0.8 108 + 0.8 120 + 0.8 11 <0.5
100 mA 1 μA 96 + 8 108 + 8 120 + 8 11 <0.5
300 mA 1 μA 96 + 24 108 + 24 120 + 24 4 <0.5
1 A 10 μA 96 + 80 108 + 80 120 + 80 3.5 <0.5
3 A 10 μA 96 + 80 108 + 80 120 + 80 4 <0.5
10 A 100 μA 96 + 800 108 + 800 120 + 800 3.5 <0.5
20 A(30 A)[2] 100 μA 96 + 800 108 + 800 120 + 800 2.8 <0.5
Note [1]: When the output is negative, the floor uncertainly is double;
Note [2]: 30 A range is optional.
  1. Output range: ±(3 μA ~ 22 A\33 A)
  2. Open-circuit and overload protection

6.3 Simulated DC Resistance

Range Resolution Accuracy Allowable Current
90days(23±5)°C 1year(23±5)°C
±(ppm*output + Ω)
0 Ω - 5 mΩ 5 mΩ 1mA~ 300mA
10 Ω 100μΩ 240 + 0.015 300 + 0.015 1mA~ 150 mA
30 Ω 100μΩ 240 + 0.015 300 + 0.015 1mA~ 150 mA
100 Ω 1 mΩ 120 + 0.015 150 + 0.015 1mA~ 80 mA
300 Ω 1 mΩ 120 + 0.03 150 + 0.03 1mA~ 40 mA
1 kΩ 10 mΩ 80 + 0.1 100 + 0.1 1mA~ 20 mA
3kΩ 10 mΩ 80 + 0.2 100 + 0.2 0.1mA~ 6mA
10 kΩ 100 mΩ 80 + 1 100 + 1 0.1mA~ 2mA
30 kΩ 100 mΩ 80 + 2 100 + 2 10μA~ 600 μA
100 kΩ 1 Ω 80 + 10 100 + 10 10μA~ 200 μA
300 kΩ 1 Ω 80 + 20 100 + 20 1μA~ 60 μA
1 MΩ 10 Ω 80 + 100 100 + 100 1μA~ 20 μA
3 MΩ 10 Ω 80 + 300 100 + 300 0.25μA~ 6 μA
10 MΩ 100 Ω 240 + 1k 300 + 1k 0.25μA~ 2 μA
30 MΩ 100 Ω 400 + 3k 500 + 3k 25nA~600nA
100 MΩ 1kΩ 1600 + 80k 2000 + 80k 25nA~200nA
200 MΩ 1kΩ 4000 + 100k 5000 + 100k 2.5nA~ 45nA
  1. Output range: 10 Ω ~ 220 MΩ
  2. Over-current and reverse connection protection

6.4 AC Voltage Output

Range Resolution Frequency (Hz) Accuracy Max Burden (mA)
[Source internal resistance]
Harmonic (%)
90 days
(23±5)°C
1 year
(23±5)°C
±(ppm*RD + mV)
30 mV 100 nV 45≤F≤1k 360 + 0.03 400 + 0.03 [1Ω] <0.5
1k<F≤1.5k 540 + 0.03 600 + 0.03 <0.5
100 mV 1 μV 45≤F≤1k 360 + 0.03 400 + 0.03 [1Ω] <0.5
1k<F≤1.5k 540 + 0.03 600 + 0.03 <0.5
300 mV 1 μV 45≤F≤1k 270 + 0.05 300 + 0.05 100 <0.5
1k<F≤1.5k 450 + 0.05 500 + 0.05 <0.5
1 V 10 μV 45≤F≤1k 270 + 0.2 300 + 0.2 300 <0.5
1k<F≤1.5k 450 + 0.2 500 + 0.2 <0.5
3 V 10 μV 45≤F≤1k 360 + 0.2 400 + 0.2 300 <0.5
1k<F≤1.5k 450 + 0.2 500 + 0.2 <0.5
10 V 100 μV 45≤F≤1k 270 + 2 300 + 2 500 <0.5
1k<F≤1.5k 450 + 2 500 + 2 <0.5
30 V 100 μV 45≤F≤1k 360 + 2 400 + 2 800 <0.5
1k<F≤1.5k 450 + 2 500 + 2 <0.5
100 V 1 mV 45≤F≤1k 270 + 20 300 + 20 400 <0.5
1k<F≤1.5k 450 + 20 500 + 20 <0.5
300 V 1 mV 45≤F≤1k 360 + 20 400 + 20 120 <0.5
1k<F≤1.5k 450 + 20 500 + 20 <0.5
1000 V 10 mV 45≤F≤1k 270 + 200 300 + 200 40 <0.5
1k<F≤1.5k 450 + 200 500 + 200 <0.5
  1. Output range: 3 mV ~ 1100 V
  2. Short-circuit and overload protection

6.5 AC Current Output

Range Resolution Frequency
 (Hz)
Accuracy Compliance Voltage  (V) Harmonic (%)
90 days
(23±5)°C
1 year
(23±5)°C
±(ppm*RD + μA)
300 μA 1 nA 45≤F≤1k 360 + 0.12 400 + 0.12 50 <0.5
1k<F≤1.5k 450 + 0.12 500 + 0.12 <0.5
3 mA 10 nA 45≤F≤1k 270 + 0.6 300 + 0.6 50 <0.5
1k<F≤1.5k 360 + 0.6 400 + 0.6 <0.5
30 mA 100 nA 45≤F≤1k 270 + 6 300 + 6 50 <0.5
1k<F≤1.5k 360 + 6 400 + 6 <0.5
300 mA 1 μA 45≤F≤1k 270 + 60 300 + 60 15 <0.5
1k<F≤1.5k 360 + 60 400 + 60 <0.5
1 A 10μA 45≤F≤1k 270 + 200 300 + 200 15 <0.5
1k<F≤1.5k 360 + 200 400 + 200 <0.5
5 A 10μA 45≤F≤1k 270 + 600 300 + 600 4 <0.5
1k<F≤1.5k 360 + 600 400 + 600 <0.5
20 A
(30 A)[1]
100μA 45≤F≤1k 270 + 4000 300 + 4000 2.5 <0.5
1k<F≤1.5k 360 + 4000 400 + 4000 <0.5
Note [1]: 30 A range is optional.
  1. Output range: 30 μA ~ 22 A or 33 A
  2. Open-circuit and overload protection

6.6 Sinusoidal Wave Frequency Output

Range[1] Resolution Accuracy
45.0000 Hz ≤ F ≤ 99.9999 Hz 0.0001 Hz ±0.01%
100.000 Hz ≤ F ≤ 999.999 Hz 0.001 Hz ±0.01%
1000.00 Hz ≤ F ≤ 1500.00 Hz 0.01 Hz ±0.01%
Note [1]: The output mode is AC voltage or AC current.
 

6.7 AC/DC Power Output

Frequency Range (f) Voltage Range (U) Current Range (I) Optimum Accuracy
%*power output [1][2]
DC 10 mV ~ 1100 V 3μA ~ 22 A/33 A ±0.05
45 Hz ~ 65 Hz 3 V ~ 600 V 0.3 mA ~ 22 A/33 A ±0.1

6.8 Phase and Power Factor Output(45 Hz ~ 65 Hz)

Phase Power Factor Accuracy
WATTS VARS λ=cosφ Phase Power Factor
90° 1.00000 0.05° 0.000%
10° 80° 0.98481 0.05° 0.015%
20° 70° 0.93969 0.05° 0.032%
30° 60° 0.86603 0.05° 0.050%
40° 50° 0.76604 0.05° 0.073%
50° 40° 0.64279 0.05° 0.104%
60° 30° 0.50000 0.05° 0.151%
70° 30° 0.34202 0.05° 0.240%
80° 10° 0.17365 0.05° 0.495%
90° 0.00000 - -
Note [1]: Phase range: 0.000 ° ~ 359.999 °, fineness: 0.005 °
Note [2]: Power factor range: -1 ~ 0 ~ 1, fineness: 0.000 1
 

6.9 Pulse Frequency Output

Range [1] Resolution Accuracy Shake
1.000 00 Hz ≤ F ≤ 9.999 99 Hz 10 μHz ±(20 ppm*RD + 20 μHz) <20 ns
10.000 0 Hz ≤ F ≤ 99.999 9 Hz 0.1 mHz
100.000 Hz ≤ F ≤ 999.999 Hz 1 mHz
1.000 00 kHz ≤ F ≤ 9.999 99 kHz 10 mHz
10.000 0 kHz ≤ F ≤ 99.999 9 kHz 0.1 Hz
100.000 kHz ≤ F ≤ 999.999 kHz 1 Hz
1.000 00 MHz ≤ F ≤ 2.000 00 MHz
  1. z
Note [1]: The output type is TTL level.
 

6.10 DC Small-signal Measurement (optional)

Type Range Measurement Range Accuracy
DCV 1 V ±(0 ~ 1.2) V ±(0.006%*RD + 0.004%*RG)
10 V ±(0 ~ 12) V ±(0.006%*RD + 0.004%*RG)
DCI 2 mA ±(0 ~ 2.4) mA ±(0.006%*RD + 0.004%*RG)
20 mA ±(0 ~ 24) mA ±(0.006%*RD + 0.004%*RG)
 

7. General Specifications

Power supply AC (220±22) V,(50±2) Hz
Maximum power consumption 600 VA
Warm up time Twice the time since last warmed up, to a maximum of 30 minutes.
Temperature performance Operating temperature:0°C~40°C
Calibration temperature:18°C~28°C
Storage temperature:-20°C~70°C
Humidity performance Operating humidity:<80% @ 30°C,<70% @ 40°C
Storage humidity:(20%~80%) R·H,No condensation
Communication interface RS232
Dimensions 450 mm(W)× 505 mm (D) × 203 mm (H), excluding handles and feets.
Weight About 19.5kg

8. Ordering Information

TD1860 Multi-function Calibrator for Calibrating 4.5 DMM &amp; Below
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below pictures & photos
TD1860 Multi-function Calibrator for Calibrating 4.5 DMM & Below
US $15,000-16,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013