• TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
  • TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
  • TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
  • TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
  • TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
  • TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ

TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ

After-sales Service: Life Time
Warranty: 12 Months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ pictures & photos
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
US $45,400-47,200 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TH0360
Power
Electricity
LCD Display
With LCD Display
Customized
Non-Customized
DC current measurement
20 mA~ 22 A
Optimal measurement uncertainty for curr
40 ppm
Resistance analog range
0 Ω ~ 1.1 GΩ
Optimal measurement uncertainty for resi
20 ppm
Transport Package
Package for Exporting
Specification
400 mm ( W ) *300 mm ( D )* 190 mm ( H ), 13Kg
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
50.00cm * 40.00cm * 25.00cm
Package Gross Weight
18.000kg

Product Description

TH0360 High Precision DC Resistance Meter Calibrator 
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ

1. Summary
TH0360 is an instrument that accurately simulates a wide range of DC standard resistances, enabling single-arm bridges, double-arm bridges, high-precision DC resistance meters, and digital microohmmeters.

2. Features
DC current measurement range: 20 mA~ 22 A
Optimal measurement uncertainty for current: 40 ppm
Resistance analog range: 0 Ω ~ 1.1 GΩ
Optimal measurement uncertainty for resistance: 20 ppm
Two-wire and four-wire resistance modes
RS232 interface
LCD touch screen

3. Applications

Calibrate a class 0.01 and below single-arm bridge
Calibrate DC resistance meters of class 0.01 and below
Calibrate a 6-digit half-digit multimeter
Calibrate DC current sources below class 0.01
Calibrate temperature measurement bridges of 0.01 and below
 
4. Characteristics
☆ Analog resistance output
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
Higher measurement accuracy with the four-wire wiring method.
Self-calibration.

☆ Multiple output methods
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
The instrument has a "fixed point output" mode, through the digital button of the operation table or click the touch screen, directly set the required output value, the instrument will automatically switch to the best range output.
☆ Multiple output methods
 
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
 
When calibrating a resistance tester, it is usually necessary to select the calibration point according to the proportion of each range of the meter to be checked.
The user can easily select the calibration point of the inspected meter through the "Percentage Output Button" on the console of this instrument or the "Percentage Check Point" on the touch screen.
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
The operating area is equipped with a "rotary encoder" that increases or decreases the output by rotating it clockwise or counterclockwise.
 
  • Statistical analysis of test data
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
S/N Function  
1 Integration period: The integration period can be set in the range of 0.5 s ~ 20 s (default 1 s), which is convenient for users to set sampling data according to actual needs;  
2 Statistical analysis: real-time recording and statistical test data, including current average Avg, mean square deviation S.dev, peak-to-peak P-P, and maximum value Max, minimum min, test number N, time time, etc., easy for users to read intuitively;  

☆ Rich communication interface and special test software
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
RS232, USB, LAN interfaces.


5. Specifications
5.1 DC current measurement
Current range Resolution Measurement uncertainty (k=2, ppm*RD + ppm*RG) [1]. Temperature coefficient
(ppm*RD/°C)
@ (15~30)°C
24 hours
( 23 ± 1 ) °C
90 days
( 23 ± 5 ) °C
1 year
( 23 ± 5 ) °C
200 mA 10 nA 18 + 6 24 + 8 30 + 10 0.5
1 A 100 nA 18 + 6 24 + 8 30 + 10 0.5
5 A 1 μA 18 + 6 24 + 8 30 + 10 0.5
20 A 10 μA 18 + 6 24 + 8 30 + 10 0.5
Note [1]: RD is the reading value and RG is the range value
     1. Measuring range: 20 m A ~ 22 A
     2. Display digits: 6 digits display
     3.Range switching: manual/automatic switching

5.2 Low value resistance simulation
Test the current Resistance range Adjust fineness Measurement uncertainty ( k=2 )
5 A ≤ I ≤ 22 A 0 ≤ R ≤ 50 mΩ 10 pH 25 ppm*RD + KI[2]*4.0 nΩ
50 μΩ < R ≤ 500 μΩ 0.1 nΩ 25 ppm*RD + KI*5.0 nΩ
500 μΩ < R ≤ 5 mΩ 1 nΩ 25 ppm*RD + KI*10 nΩ
5 mΩ < R ≤ 50 mΩ 10 nΩ 25 ppm*RD
50 mΩ < R ≤ 500 mΩ 0.1 mΩ 25 ppm*RD
1 A ≤ I ≤ 5.5 A 0 ≤ R ≤ 200 mΩ 0.1 nΩ 25 ppm*RD + KI*16 nΩ
200 μΩ < R ≤ 2 mΩ 1 nΩ 25 ppm*RD + KI*20 nΩ
2 mΩ < R ≤ 20 mΩ 10 nΩ 25 ppm*RD + KI*50 nΩ
20 mΩ < R ≤ 200 mΩ 100 nΩ 25 ppm*RD
200 mΩ < R ≤ 2 Ω 1 mΩ 25 ppm*RD
0.2 A ≤ I ≤ 1.1 A 0 ≤ R ≤ 1 mΩ 1 nΩ 25 ppm*RD + KI*80 nΩ
1 mΩ < R ≤ 10 mΩ 10 nΩ 25 ppm*RD + KI*100 nΩ
10 mΩ < R ≤ 100 mΩ 100 nΩ 25 ppm*RD + KI*200 nΩ
100 mΩ < R ≤ 1 Ω 1 mΩ 25 ppm*RD
1 Ω < R ≤ 10 Ω 10 mΩ 25 ppm*RD
50 mA ≤ I ≤ 220 mA 0 ≤ R ≤ 5 mΩ 1 nΩ 25 ppm*RD + KI*0.4 μΩ
5 mΩ < R ≤ 50 mΩ 10 nΩ 25 ppm*RD + KI*0.5 μΩ
50 mΩ < R ≤ 500 mΩ 100 nΩ 25 ppm*RD + KI*1.0 μΩ
500 mΩ < R ≤ 5 Ω 1 mΩ 25 ppm*RD
5 Ω < R ≤ 50 Ω 10 mΩ 25 ppm*RD
Note [2]: KI is the current coefficient, KI = RG/I, where RG is the current range value and I is the input current value.
  1. Resistance simulation range: 0 Ω ~ 50 Ω
  2. Wiring mode: four-wire system
  3. Current input range: 50 mA ~ 22 A
  4. Range switching: manual/automatic switching
5.3 Medium and high value resistor simulation
Range Adjust fineness Measurement uncertainty ( k=2, ppm*RD+Ω ) Input current
24 hours
(23±1)°C
90 days
(23±5)°C
1 year
(23±5)°C
10 Ω 100 mΩ 20 + 0.001 32 + 0.001 40 + 0.001 1 mA ~ 150 mA
30 Ω 150 mΩ 15 + 0.002 24 + 0.002 30 + 0.002 1 mA ~ 150 mA
100 Ω 500 mΩ 12 + 0.002 20 + 0.002 25 + 0.002 1 mA ~ 80 mA
300 Ω 1.5 mΩ 12 + 0.003 20 + 0.003 25 + 0.003 1 mA ~ 60 mA
1 kΩ 5 mΩ 12 + 0.01 18 + 0.01 20 + 0.01 1 mA ~ 12 mA
3 kΩ 15 mΩ 12 + 0.03 18 + 0.03 20 + 0.03 0.1 mA ~ 4 mA
10 kΩ 50 mΩ 12 + 0.1 18 + 0.1 20 + 0.1 0.1 mA ~ 2 mA
30 kΩ 150 mΩ 12 + 0.3 18 + 0.3 20 + 0.3 10 μA ~ 400 μA
100 kΩ 500 mΩ 15 + 1 24 + 1 30 + 1 10 μA ~ 200 μA
300 kΩ 1.5 Ω 17 + 3 28 + 3 35 + 3 1 μA ~ 40 μA
1 MΩ 5 Ω 17 + 10 28 + 10 35 + 10 1 μA ~ 20 μA
3 MΩ 15 Ω 30 + 30 48 + 30 60 + 30 0.25 μA ~ 4 μA
10 MΩ 50Ω 65 + 100 110 + 100 130 + 100 0.25 μA ~ 2 μA
30 MH 150 Ω 125 + 2.5k 150 + 2.5k 200 + 2.5k 25 nA ~ 400 nA
100 MΩ 1 kΩ 250 + 3k 400 + 3k 500 + 3k 25 nA ~ 200 nA
300 MΩ 1.5 kΩ 1200 + 0.1M 1500 + 0.1M 2000 + 0.1M 2.5 nA ~ 70 nA
1 GΩ 5 kΩ 6000 + 0.5M 7000 + 0.5M 8000 + 0.5M 1 nA ~ 20 nA
  1. Resistance analog range: 1 Ω ~ 1.1 G Ω
  2. Wiring mode: four-wire system or two-wire system
  3. Current input range: 1 nA ~ 150 mA
  4. Range switching: manual/automatic switching
6.  General Specifications
Power supply AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz;
Warm-up time Not less than 1 hour, and the warm-up time again after shutting down in the middle should not be less than 2 times the shutdown time;
Maximum power consumption 150 VA
Temperature performance Working temperature: 18 °C ~ 28 °C;
Storage temperature: -1 0 °C ~ 50 °C;
Humidity performance Operating humidity:( 20 % ~ 80% ) R H, no condensation;
Storage humidity: < 85% R· H, no condensation;
Altitude < 3000 m
Quality Approx. 13 kg
Interfaces RS 232,USB,IP
Size 400 mm ( W ) × 300 mm ( D ) × 190 mm ( H ) ( without feet and handles).
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 &Omega; ~ 1.1 G&Omega;
 
 
Company Profile
 

TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 &Omega; ~ 1.1 G&Omega;

TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 &Omega; ~ 1.1 G&Omega;TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 &Omega; ~ 1.1 G&Omega;
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ pictures & photos
TH0360 High Precision DC Resistance Meter Calibrator, Optimal 20 ppm, 0 Ω ~ 1.1 GΩ
US $45,400-47,200 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013