• TA2000 AC Power Calibrator with High Precision AC power Source
  • TA2000 AC Power Calibrator with High Precision AC power Source
  • TA2000 AC Power Calibrator with High Precision AC power Source
  • TA2000 AC Power Calibrator with High Precision AC power Source
  • TA2000 AC Power Calibrator with High Precision AC power Source
  • TA2000 AC Power Calibrator with High Precision AC power Source

TA2000 AC Power Calibrator with High Precision AC power Source

After-sales Service: Life Time
Warranty: 12 Months Excellent After-Sales Service
Power: Electricity
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TA2000 AC Power Calibrator with High Precision AC power Source pictures & photos
TA2000 AC Power Calibrator with High Precision AC power Source
US $21,000-37,200 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
TA2000
Voltage Output
0.3 V ~ 1100 V
Current Output
0.3 mA ~ 110 A
LCD Display
With LCD Display
Customized
Non-Customized
AUX output
0.5 mV ~ 5.5 V
Frequency
40 Hz ~ 70 Hz/1500 Hz
Accuracy
Class 0.02/0.05
Distortion Factor
<0.5%
Transport Package
Package for Exporting
Specification
450 mm(W); 470 mm (D); 205 mm (H)
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
50.00cm * 55.00cm * 25.00cm
Package Gross Weight
35.000kg

Product Description

TA2000 AC Power Calibrator 

TA2000 AC Power Calibrator with High Precision AC power Source

1. Summary

TA2000 is a high precision AC Power source standard with wide range, It's applied for calibrating AC power meters,calibrating AC Voltmeter,calibrating AC Ammeter,calibrating Phase Meter and Frequency Meter. The optional electrical energy function can be used for testing single phase AC energy meter and AC Clamp Ammeter.
 

2. Features

  1. ACV output: 0.3 V ~ 1100 V
  2. ACI output: 0.3 mA ~ 110 A
  3. AUX output: 0.5 mV ~ 5.5 V
  4. F: 40 Hz ~ 70 Hz(1500 Hz is optional)
  5. Voltage/Current accuracy: class 0.02/0.05
  6. Phase accuracy: ±0.01° / ±0.02°
  7. Adjustment fineness: 0.001%
  8. Distortion factor: <0.5%
  9. Harmonic voltage/current output(optional)
  10. AC energy measurement(optional)

3. Application



 

 Calibrate AC electrical meter
TA2000 AC Power Calibrator with High Precision AC power Source
  1. ACV output: 0.3 V ~ 1100V@40 Hz ~ 70 Hz, 300 [email protected] kHz
  2. ACI output: 0.3 mA ~ 100 A @40 Hz ~ 70 Hz, 50 [email protected] kHz
  3. Application for calibrating AC voltage/current meter
  4. 1.5 kHz is optional.

 Calibrate AC power meter
TA2000 AC Power Calibrator with High Precision AC power Source
  1. Application 1: Output a virtual standard power source through AC current and voltage source, it's applied for calibrating conventional AC power meter. 
  2. Application 2: Output a virtual standard power source through AC small-signal voltage and AC voltage source, it's applied for calibrating AC power meter with current transducer. 
  3. Calibrate active power meter, reactive power meter, volt-ampere meter, power frequency phase meter, power factor meter, power analyzer, etc.

 Calibrate AC clamp ammeter(optional)
TA2000 AC Power Calibrator with High Precision AC power Source
  1. Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters.
 
 Detect AC energy meter(optional)
TA2000 AC Power Calibrator with High Precision AC power Source
  1. Detect AC energy meter.


 

4. Characteristics

Wide output range
TA2000 AC Power Calibrator with High Precision AC power Source
 
 Harmonic output(optional)
TA2000 AC Power Calibrator with High Precision AC power Source
  1. 2nd ~ 21th harmonic @ 50 Hz.

Multiple output\adjustment methods
TA2000 AC Power Calibrator with High Precision AC power Source
  1. "Direct output" mode: the value output can be set directly by physical key or touch screen.
TA2000 AC Power Calibrator with High Precision AC power Source
  1. Calibration of the analog pointer meter usually needs to test scale by scale, especially "differences between rising and falling" (the change caused by the rise and fall of the calibration point).
  2. Remote box can realize the coarse and fine adjustment of current or voltage.

Multiple output\adjustment methods
  1. "Direct output" mode: the value output can be set directly by physical key or touch screen.
TA2000 AC Power Calibrator with High Precision AC power Source
  1. Use the key 10%,10%,×10,÷10 on the front panel, can realize the adjustment of the quantity value, and can also be used to perform the relevant test of linearity.


 

6. Specifications

6.1 AC Voltage Output

Range Frequency [1] Resolution Voltage Output Maximum Burden Current
3 V 40 Hz ~ 70 Hz 10 μV 0.30000 V ~ 3.30000 V 500mA
70 Hz ~ 1500 Hz
10 V 40 Hz ~ 70 Hz 100 μV 1.0000 V ~ 11.0000 V 500mA
70 Hz ~ 1500 Hz
30 V 40 Hz ~ 70 Hz 100 μV 3.0000 V ~ 33.0000 V 500mA
70 Hz ~ 1500 Hz
100 V 40 Hz ~ 70 Hz 1 mV 10.000 V ~ 110.000 V 350 mA
70 Hz ~ 1500 Hz
300 V 40 Hz ~ 70 Hz 1 mV 30.000 V ~ 330.000 V 120 mA
70 Hz ~ 1500 Hz
600 V 40 Hz ~ 70 Hz 1 mV 60.000 V ~ 660.000 V 50 mA
1000 V 40 Hz ~ 70 Hz 10 mV 100.00 V ~ 1100.00 V 40 mA
Note: [1] 70 Hz ~ 1500 Hz is optional.
  1. Adjustment fineness: 0.001%*RG, 6 digits display.
  2. Short-circuit and overload protection
 
Range Frequency Short-term Stability (±%*RG/min) Accuracy
±(ppm*RD+ppm*RG) [1]
Distortion Factor (%)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
3 V 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
10 V 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
30 V 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
100 V 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
300 V 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
600 V 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
1000 V 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
Note: [1] RD is reading, RG is range, same below.

6.2 AC Current Output

Range Frequency [1] Resolution Current Output Maximum Burden Voltage
3 mA 40 Hz ~ 70 Hz 10 nA 0.30000 mA ~ 3.30000 mA 50 V
70 Hz ~ 1500 Hz
10 mA 40 Hz ~ 70 Hz 100 nA 1.0000 mA ~ 11.0000 mA 50 V
70 Hz ~ 1500 Hz
30 mA 40 Hz ~ 70 Hz 100 nA 3.0000 mA ~ 33.0000 mA 50 V
70 Hz ~ 1500 Hz
100 mA 40 Hz ~ 70 Hz 1 μA 10.000 mA ~ 100.000 mA 50 V
70 Hz ~ 1500 Hz
300 mA 40 Hz ~ 70 Hz 1 μA 30.000 mA ~ 330.000 mA 50 V
70 Hz ~ 1500 Hz
1 A 40 Hz ~ 70 Hz 10μA 0.10000 A ~ 1.10000 A 50 V
70 Hz ~ 1500 Hz
3 A 40 Hz ~ 70 Hz 10μA 0.30000 A ~ 3.30000 A 30 V
70 Hz ~ 1500 Hz
10 A 40 Hz ~ 70 Hz 100μA 1.0000 A ~ 10.0000 A 6 V
70 Hz ~ 1500 Hz
30 A 40 Hz ~ 70 Hz 100μA 3.0000 A ~ 33.0000 A 2.5 V
70 Hz ~ 1500 Hz
100 A 40 Hz ~ 70 Hz 1 mA 10.000 A ~ 110.000 A 1.2 V
70 Hz ~ 1500 Hz 10.000 A ~ 50.000 A
Note: [1] 70 Hz ~ 1500 Hz is optional.
  1. Current output: 0.3 mA ~ 110 A @ 40 Hz ~ 70 Hz; 0.3 mA ~ 50 A @ 70Hz ~ 1.5 kHz.
  2. Adjustment Fineness: 0.001%*RG, 6 digits display.
  3. Open-circuit and overload protection
 
Range Frequency Short-term Stability (±%*RG/min) Accuracy
±(ppm*RD+ppm*RG) [1]
Distortion Factor (%)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
3 mA 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
10 mA 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
30 mA 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
100 mA 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
300 mA 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
1 A 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
3 A 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
10 A 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
30 A 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0
100 A 40 Hz ~ 70 Hz 0.01 0.005 300 + 200 120 + 80 <0.5
70 Hz ~ 1500 Hz <1.0

6.3 AC Small-signal Voltage Output

Range Frequency [1] Resolution Voltage Output Maximum Burden Current
5 mV 40 Hz ~ 70 Hz 10 nV 0.50000 mV ~ 5.50000 mV 10 mA
70 Hz ~ 1500 Hz
20 mV 40 Hz ~ 70 Hz 100 nV 2.0000 mV ~ 22.0000 mV 10 mA
70 Hz ~ 1500 Hz
50 mV 40 Hz ~ 70 Hz 100 nV 5.0000 mV ~ 55.0000 mV 10 mA
70 Hz ~ 1500 Hz
200 mV 40 Hz ~ 70 Hz 1 μV 20.000 mV ~ 220.000 mV 10 mA
70 Hz ~ 1500 Hz
500 mV 40 Hz ~ 70 Hz 1 μV 50.000 mV ~ 550.000 mV 10 mA
70 Hz ~ 1500 Hz
2 V 40 Hz ~ 70 Hz 10μV 0.20000 V ~ 2.20000 V 10 mA
70 Hz ~ 1500 Hz
5 V 40 Hz ~ 70 Hz 10μV 0.50000 V ~ 5.50000 V 10 mA
70 Hz ~ 1500 Hz
Note: [1] 70 Hz ~ 1500 Hz is optional.
  1. Adjustment Fineness: 0.001%*RG, 6 digits display.
  2. Short-circuit and overload protection
 
Range Frequency Short-term Stability (±%*RG/min) Accuracy
±(ppm*RD+μV)
Distortion Factor (%)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
5 mV 40 Hz ~ 70 Hz 0.5 0.2 300 + 20 120 + 10 <1.0
70 Hz ~ 1500 Hz <1.0
20 mV 40 Hz ~ 70 Hz 0.1 0.05 300 + 20 120 + 10 <1.0
70 Hz ~ 1500 Hz <1.0
50 mV 40 Hz ~ 70 Hz 0.05 0.02 300 + 20 120 + 10 <1.0
70 Hz ~ 1500 Hz <1.0
200 mV 40 Hz ~ 70 Hz 0.05 0.02 300 + 100 120 + 60 <0.5
70 Hz ~ 1500 Hz <1.0
500 mV 40 Hz ~ 70 Hz 0.05 0.02 300 + 100 120 + 60 <0.5
70 Hz ~ 1500 Hz <1.0
2 V 40 Hz ~ 70 Hz 0.02 0.01 300 + 400 120 + 150 <0.5
70 Hz ~ 1500 Hz <1.0
5 V 40 Hz ~ 70 Hz 0.02 0.01 300 + 1000 120 + 400 <0.5
70 Hz ~ 1500 Hz <1.0
Note: [1] RD is reading, RG is range, same below.

6.4 Sinusoidal Wave Frequency Output

Range Resolution Accuracy
Class 0.05 Class 0.02
40.0001Hz ~ 99.9999 Hz 0.0001 Hz ±0.02% ±0.01%
100.000 Hz ~ 999.999 Hz 0.001 Hz ±0.02% ±0.01%
1000.00 Hz ~1500.00 Hz 0.01 Hz ±0.02% ±0.01%
 

6.5 AC Power Output

Frequency Range
(f)
Voltage Range
(U)
Current Range
(I)
Low Voltage Range
(Aux)
Phase Range
(φ)
Power Factor
Range
(λ)
40 Hz ~ 70 Hz 0.3 V ~ 600 V 0.3 mA ~ 110 A 0.5 mV ~ 5.5 V 0°~360° -1~0~1
70 Hz ~ 1500 Hz 0.3 V ~ 330 V 0.3 mA ~ 50 A 0.5 mV ~ 5.5 V 0°~360° -1~0~1
Note [1]: active power |sinφ|≥0.5,reactive power |cosφ|≥0.5;
Note [2]: For more accurate technical indicators of power accuracy or power accuracy under other power factors.
 

6.6 Phase and Power Factor Adjustment

Phase Power factor Accuracy
Phase Power factor
WATTS VARS λ=cosφ Class 0.05 Class 0.02 Class 0.05 Class 0.02
90° 1.00000 0.02° 0.01° 0.000% 0.000%
10° 80° 0.98481 0.02° 0.01° 0.006% 0.003%
20° 70° 0.93969 0.02° 0.01° 0.013% 0.006%
30° 60° 0.86603 0.02° 0.01° 0.020% 0.010%
40° 50° 0.76604 0.02° 0.01° 0.029% 0.015%
50° 40° 0.64279 0.02° 0.01° 0.042% 0.021%
60° 30° 0.50000 0.02° 0.01° 0.060% 0.030%
70° 30° 0.34202 0.02° 0.01° 0.096% 0.048%
80° 10° 0.17365 0.02° 0.01° 0.198% 0.099%
90° 0.00000 - - - -
  1. [1] Phase range: 0.000°~359.999°, adjustment fineness: 0.005°
  2. [2] Power factor range: -1 ~ 0 ~ 1, adjustment fineness: 0.000 1
  3. [3] Other accuracy of power factor formula:TA2000 AC Power Calibrator with High Precision AC power Source

6.7Harmonic Output(optional)
  1. 2nd ~ 31th
  2. Amplitude: 0 ~ 40%
  3. Phase: 0.0° ~ 359.9°
 

6.8 Energy Testing(optional)

  1. Energy pulse output: 60 kHz for high frequency range, 6 Hz for low frequency range
  2. Energy pulse input: frequency ≤200 kHz, voltage amplitude: 0…3.3 V…24 V
 

7. General Specifications

Power supply AC (220±22) V, (50±2) Hz
Maximum power
consumption
600 VA
Warm up time Twice the time since last warmed up, to a maximum of 30 minutes.
Temperature performance Operating temperature: 0°C~40°C
Calibrating temperature: 18°C~28°C
Storage temperature: -20°C~70°C
Humidity performance Operating humidity: <80% @ 30°C, <70% @ 40°C
Storage humidity: (20%~80%) R·H, No condensation
Communication interface RS232
Dimensions 450 mm(W)× 470 mm (D) × 205 mm (H), Handles and feets excluded.
TA2000 AC Power Calibrator with High Precision AC power Source
Weight About 30.5 kg
 

 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TA2000 AC Power Calibrator with High Precision AC power Source pictures & photos
TA2000 AC Power Calibrator with High Precision AC power Source
US $21,000-37,200 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013