• TD3650 Three-phase Energy Meters calibration/Test bench
  • TD3650 Three-phase Energy Meters calibration/Test bench
  • TD3650 Three-phase Energy Meters calibration/Test bench
  • TD3650 Three-phase Energy Meters calibration/Test bench
  • TD3650 Three-phase Energy Meters calibration/Test bench
  • TD3650 Three-phase Energy Meters calibration/Test bench

TD3650 Three-phase Energy Meters calibration/Test bench

After-sales Service: Life Time
Warranty: 12 Months Excellent for Service
Power: Electricity
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD3650 Three-phase Energy Meters calibration/Test bench pictures & photos
TD3650 Three-phase Energy Meters calibration/Test bench
US $32,000-82,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD3650
Voltage Output
576V
Current Output
120A
LCD Display
With LCD Display
Customized
Non-Customized
Frequency
45 Hz ~ 100 Hz
Accuracy
Class 0.02/ Class 0.05
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
250.00cm * 100.00cm * 100.00cm
Package Gross Weight
100.000kg

Product Description

TD3650 Multifunction Testing Apparatus for Three-Phase Energy Meters
TD3650 Three-phase Energy Meters calibration/Test bench

1. Summary

TD3650 is applied for the verification of new three-phase energy meters. TD3650 supports simultaneous verification of 3 to 16 three-phase energy meters (Three-phase electrical meters, Three-phase smart electricity meters, Three-phase smart IoT electricity meters, etc.) with the same voltage/current range, different meter constant.
 

2. Features

2.1 Basic Features

  1. Maximum output capacity: 576 V / 120 A.
  2. Fundamental frequency: 45 Hz ~ 100 Hz.
  3. Accuracy: class 0.02 or 0.05.
  4. Minimum current output: As low as 0.2 mA.
  5. Auto range: Automatic range switching and load matching.
  6. Energy measurement: Positive / negative active and reactive energy.
  7. Harmonic output: The 2nd ~ 63st @ 50 / 60 Hz, Harmonic content / phase are programmable.
  8. High-order harmonic test: Built in high-order harmonic test schemes. So it automatically superposes the 15fnom to 40fnom sweep signals to the voltage and current loops and reads the data of each harmonic to measure the error offset caused by the high-order harmonic.
  9. Complex waveform test: Built in square-wave, peaked wave, even harmonics, odd harmonics and other schemes. It also allows users to customize other complex waveforms for influence quantity test.
  10. DC and even harmonics test: Equipped with TD3410 half wave rectifier box.
  11. Daily reckoning error test: Built in standard clock tester.
  12. Automatic patrol inspection: Support automatic patrol inspection.
  13. Connection: Equipped with special pressure gauge holder.
  14. Communication: DUT through RS-485 port.
  15. Energy pulse: Electric and optical pulse sampling ports.
  16. Multi-position verification platform: Optional 3,6,12,16 positions.
  17. Mobile control unit: LCD touch screen for value output.
  18. Professional verification software: Support semi-automatic or fully automatic verification of the DUT, data management and certificate export. The software has the function of single point multiple tests, the test interval can be set, and the error curve can be drawn automatically.
 

2.2 Optional Features

  1. Offering compatibility with both single/three-phase: The Potential Transformer Offer compatibility with both single/three-phase (The single-phase energy meters need Manual wiring). Up to 12 test positions.
  2. Current Transformer: The Current Transformer add the capability to test energy meter without keeping its voltage terminal separate from its current terminal. Up to 12 test positions.
  3. Auxiliary supply: AC/DC: 100V~240V; It can support the power consumption test of auxiliary power supply circuit and auxiliary power supply voltage change test.
  4. Power consumption test of voltage circuit: Only one test position is supported.
  5. Power consumption test of current circuit: Multiple-positions are supported.
  6. Burden current fast change test: The user can set the duration of ton and toff, as well as the total time for a single test. The current switches at zero crossing and switches off and on within one nominal frequency period. The repetition time of single test was more than 4 hours.
  7. AC voltage dip and short interruption test: AC Voltage dips and interruptions test supporting voltage circuit power supply.
  8. Smart electricity meter function test: Cost control function test, Freezing test, Key update test, Parameter update test, The remote control test, Safety certification test, Events recording test, Communication protocol consistency check, etc.
  9. Fault earthing test: Support fault earthing test. In the case of fault earthing and 10% overvoltage, the electricity meter connected to the isolated distribution network with fault earthing suppressor or star contact by three-phase four-wire connection is examined.
  10. Standard meter: Class 0.05/0.02 of conventional or harmonic standard electricity meter.
  11. Harmonic energy: Support harmonic power/measurement accuracy test.
 

3. Verification Items

NO. Verification Items Completion
(standard)
Remarks
1 Appearance, signs, power check Observation  
2 Accuracy Test Initial inherent error test  
3 Starting current test  
4 Test of no-load  
5 Meter constant test  
6 Electric energy display value combination error  
7 Demand indicating value error  
8 A clock test powered by a power supply  
9 Impact of the standby power supply on the clock  
10 Error consistency test  
11 Variation requirement test  
12 The load current rises and falls worse test  
13 Repeat test  
14 EMC Voltage dips and interruptions Optional-Fast change test of load current  
15 Resistance to Other Influences Harmonic in voltage-current circuits -the 5st harmonic test  
16 Harmonic in voltage-current circuits - square-wave test  
17 Harmonic in voltage-current circuits - peaked wave test  
18 Interharmonic in the current circuits - the pulse train triggers the waveform   
19 Odd harmonic in voltage-current circuits -waveform test triggered by 90 degree phase  
20 Impact Test of DC and Even Harmonics -waveform of half wave rectification  
21 Load unbalance test  
22 Voltage change test  
23 One or two-phase voltage interruption  
24 Frequency change test  
25 Reverse phase sequence test  
26 Auxiliary power supply voltage change test Auxiliary power supply (optional)  
27 Burden current fast change test Burden current fast change test (optional)  
28 Self-heating test  
29 High-order harmonic test  
30 Fault earthing test(Only for three-phase four-wire transformer type energy meter) Fault earthing test (optional) Only for class 0.05 TD3650
31 Electrical Performance Test Power consumption test of voltage circuits optional  
32 Power consumption test of current circuits optional  
33 Power consumption test of auxiliary power supply circuit optional  
34 IOT Electricity Meter Harmonic power accuracy test harmonic power(optional)  
35 Harmonic measurement accuracy test  
 

4. Specifications

4.1 AC Voltage Output

Range Resolution Short-term Stability
 ( % / min )
Accuracy
±(ppm of reading + ppm of range) [1]
Distortion Factor
( % )
Class 0.05 Class 0.02 Class 0.05 Class 0.02
60 V 0.1 mV 0.01 0.005 200 + 50 60 + 40 < 0.3
120 V 1 mV 0.01 0.005 200 + 50 60 + 40 < 0.3
240 V 1 mV 0.01 0.005 200 + 50 60 + 40 < 0.3
480 V 1 mV 0.01 0.005 200 + 50 60 + 40 < 0.3
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
  1. Output range: 0 V~264 V, 6-digits display, load capacity: 15VA/ (phase · position)
  2. Symmetry: Voltage ≤ 0.2%, Phase ≤ 0.5°
  3. Protective function: Short-circuit protection, Overload protection
 

4.2 AC Current Output

Range Resolution Short-term Stability
 ( % / min )
Accuracy
±(ppm of reading + ppm of range) 
Distortion Factor
( % )
Class 0.05 Class 0.02 Class 0.05 Class 0.02
5 mA 10 nA 0.03 0.02 400 + 300 240 + 160 < 1
10 mA 0.1 μA 0.02 0.01 300 + 200 120 + 80 < 0.5
20 mA 0.1 μA 0.02 0.01 300 + 200 120 + 80 < 0.5
50 mA 0.1 μA 0.02 0.01 200 + 50 60 + 40 < 0.5
100 mA 1 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
200 mA 1 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
500 mA 1 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
1 A 10 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
2 A 10 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
5 A 10 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
10 A 100 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
20 A 100 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
50 A 100 μA 0.01 0.005 200 + 50 60 + 40 < 0.5
100 A 1 mA 0.01 0.005 200 + 50 60 + 40 < 0.5
  1. Output range: 1 mA~120 A, 6-digits display, load capacity: 30VA/ (phase · position)
  2. Symmetry: Current ≤ 0.5%, Phase ≤ 0.5°
  3. Protective function: Open-circuit protection, Overload protection
 

4.3 Frequency / Phase

Measurement Type Class 0.05 Class 0.02
Frequency Measuring Range 45 Hz~100 Hz 45 Hz~100 Hz
Minimum Resolution 0.000 01 Hz 0.000 01 Hz
Accuracy ±0.005%*RD ±0.005%*RD
Phase
(I ≥ 50mA)
Measuring Range 0~360° 0~360°
Minimum Resolution 0.000 1° 0.000 1°
Accuracy ±0.012° ±0.006°
 

4.4 Power / Energy

Voltage Range Current Range Power Factor Accuracy±(% of reading)
Class 0.05 Class 0.02
30 V ≤ U ≤ 480 V 50 mA ≤ I ≤120 A 0.5L~1~0.5C 0.05%*RD 0.02%*RD
10 mA ≤ I < 50 mA 1 0.05%*RD 0.02%*RD
0.04%*RD
0.5L~1~0.5C 0.08%*RD
3 mA ≤ I < 10 mA 1 0.08%*RD 0.04%*RD
0.5L~1~0.5C 0.15%*RD 0.08%*RD
0.2 mA ≤ I < 3 mA 1 0.08%*RD×3mA/I 0.04%*RD×3mA/I
  1. Stability of output power: 0.02% / 2min (Class 0.05),0.05% / 2min (Class 0.1);
  2. Measuring range of power/energy: Combination of AC voltage and AC current range  ;
  3. Measuring range of power factor: -1.000 00…0.000 00…1.000 00;
  4. Standard electric energy pulse output: High frequency pulse output port outputs 60KHz at full range, low frequency pulse output port outputs 6Hz at full range;
  5. Standard electric energy pulse input: frequency ≤ 200 kHz,voltage:0…3.3 V…24 V;
  6. Electric energy error display: Auto, resolution is 0.0001%.
 

4.5 Clock

  1. Daily reckoning error bounds: ±0.05 s/d 
 

5. General Specifications

Power Supply AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz
Warm Up Time 30 min
Temperature
Performance
Storage temperature: 5°C~45°C
Operating temperature: -10°C~55°C  
Humidity Performance Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C
Storage humidity: (20%~80%) R·H, non-condensing
Elevation < 3000 m
Communication Interface RS232, RS485, LAN
Dimensions of Test Bench
(L*W *table H / total H, mm)
Position number 3 test positions 6 test positions 12 test positions 16 test positions
Manual wiring 1350*800*750/1140 1950*800*750/1140 -- --
Crimping wiring 1350*750*750/1395 1850*750*750/1395 1830*750*610/1765 2350*750*610/1765
Dimensions of Computer Desk
(L*W*H, mm)
No Standard meter 1000*800*750
Standard meter 1500*800*750


 

6. Ordering Information

TD3650 Three-phase Energy Meters calibration/Test bench
 
Other Options
Tick Optional Function Description
  Manual Wiring The default option is Crimping wiring (with meter rack), Manual wiring is optional.
  Offering Compatibility with both Single-phase and Three-phase Up to 12 test positions
  Current Transformer Up to 12 test positions
  Auxiliary Supply AC/DC: 100V~240V, Up to 3 test positions
  Power Consumption Test of Voltage Circuit Up to 1 test position (proposal)
  Power Consumption Test of Current Circuit: Up to 3 test positions (proposal)
  Burden Current Fast Change Test Once selected, all test positions are supported;
AC voltage dip and short interruption test.
  Fault Earthing Test  
  Standard Meter TD3300 Standard meter(Class 0.05 / 0.02)
  Harmonic Energy TD3300-R Standard meter(Class 0.05 / 0.02)

Company Profile
 

TD3650 Three-phase Energy Meters calibration/Test bench

TD3650 Three-phase Energy Meters calibration/Test benchTD3650 Three-phase Energy Meters calibration/Test bench

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD3650 Three-phase Energy Meters calibration/Test bench pictures & photos
TD3650 Three-phase Energy Meters calibration/Test bench
US $32,000-82,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013