• TD1580 DC Energy Meters Testing Device
  • TD1580 DC Energy Meters Testing Device
  • TD1580 DC Energy Meters Testing Device
  • TD1580 DC Energy Meters Testing Device
  • TD1580 DC Energy Meters Testing Device
  • TD1580 DC Energy Meters Testing Device

TD1580 DC Energy Meters Testing Device

After-sales Service: Life Time
Warranty: 12 months Excellent After-sales Service
Power: Electricity
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD1580 DC Energy Meters Testing Device pictures & photos
TD1580 DC Energy Meters Testing Device
US $77,500-137,500 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD1580
Voltage Output
10mV~1150V
Current Output
5uA~120A
Customized
Non-Customized
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
300.00cm * 120.00cm * 160.00cm
Package Gross Weight
120.000kg

Product Description

TD1580 DC Energy Meters Testing Device
 
TD1580 DC Energy Meters Testing Device
*The pictures are for reference only. The configuration and details may vary depending on the application scenarios. 

1. Summary

TD1580 is a comprehensive equipment dedicated to the verification and type evaluation of static DC electrical energy meter. It is composed of DC voltage standard source, DC current standard source, DC small-signal voltage source, DC standard phantom power source composed of voltage-current combination, etc. It is applicable to the verification of direct connected or indirect connected DC electrical energy meters or the completion of most tests of type evaluation.
 

2. Features

  1. There are two specifications of class 0.02, class 0.05 available.
  2. DC standard voltage source: 10 mV~1150V(1500 V optional).
  3.  DC standard current source: 5 μA~120 A(600 A optional).
  4. DC four-terminals small-signal voltage source: 10 μV~ 4.4 V.
  5. DC + AC output mode for ripple effect test.
  6. Programmed positive and negative voltage output to complete reverse polarity connection test of voltage line.
  7. Auxiliary power supply is used to supply power for electronic meters for measuring DC electrical energy(type A).
  8. Power supply voltage variation can be set for voltage dip and short interruption test.
  9. The power supply has the loop current measurement function to detect the power consumption of meter under test.
  10. Standard second pulse measurement, used to detect the daily reckoning error of electric energy meter. 
  11. Optional single/three test positions energy verification test bench.

3. Applications

 Verification DC Energy Meter
TD1580 DC Energy Meters Testing Device
  1. Application Scenario 1: The maximum DC voltage output is 1500 V,meeting the requirements of 1.15 Un voltage test of 1 kV DC energy meters; The maximum DC current output is 600 A, meeting the requirements of 1.2 In current test of 100 A DC energy meters. With the energy pulse measurement function, the direct connected DC energy meter test can be completed.
  2. Application Scenario 2:The instrument is equipped with a 10 μV~4.4 V four-terminals small-signal voltage source, a 1500 V DC voltage source and energy pulse measurement function, and can carry out relevant tests on indirect connected DC energy meter.
  3. Application Scenario 3:The instrument supports 600 A maximum current output option,with 1500 V DC voltage source and energy pulse measurement, and carry out the overall related test work of indirect connected DC energy meter and DC shunt.

4. Characteristics

 Wide Range DC Power Output 
TD1580 DC Energy Meters Testing Device
  1. The maximum output of the DC standard voltage source is 1500 V, The maximum output of the DC standard current source is 600 A; The output range of the DC standard small-signal voltage source used for the verification of indirect connected DC energy meters is (10 μV~4.4 V);
 
 DC+AC(DC ripple)Output
TD1580 DC Energy Meters Testing Device
  1. DC+AC output mode:The output of each DC current can be superimposed with alternating component (ripple) with adjustable amplitude, frequency (100 Hz~1 kHz), phase to complete the ripple impact test of the energy meter under test.

 Clock Check Function
TD1580 DC Energy Meters Testing Device
  1. Built in clock module with precision up to 0.2 ppm, which can accurately measure the second pulse signal for daily reckoning error test.
  2. Built in GPS module and antenna can receive GPS standard clock signal.
 
 Auxiliary Power Supply(Power Consumption Test)
TD1580 DC Energy Meters Testing Device
  1. Each meter position has built-in auxiliary supply, which can provide DC 24 V, 48 V or AC 220 V power supply for Class A electric energy meter.
  2. All auxiliary power supplies have independent power consumption measurement function, which can measure the real-time power consumption of DC energy meter.

 Adjustable Power Supply Voltage(Voltage Dip and Short Interruption test)
TD1580 DC Energy Meters Testing Device
  1. The voltage change time of auxiliary supply can be set within 20 ms~1 min to complete voltage dip and short interruption test.
 
 Voltage Reverse Polarity Output
TD1580 DC Energy Meters Testing Device
  1. TD1580 voltage output interface supports the positive and negative polarity output of voltage by adjusting the positive and negative electrical parameters on the software interface, and can conduct the voltage reverse polarity connection experiment on the DC energy meter. 

 Professional Test Software
TD1580 DC Energy Meters Testing Device
  1. With RS232, LAN, USB, RS485 communication interfaces, software functions can be customized according to customer needs.


 

5. Specifications

5.1 DC Voltage Output

Range Resolution Short Term Stability
(% / min)
Accuracy (k=2)
(ppm of reading + ppm of range) [1]
Maximum Burden Current (mA) Ripple ( % )
Class 0.05 Class 0.02 Class 0.05 Class 0.02
100 mV 0.1 μV 0.01 0.005 120 + 80 80 + 60 100 < 0.2
300 mV 0.1 μV 0.008 0.004 120 + 80 80 + 60 100 < 0.2
1 V 1 μV 0.005 0.002 120 + 80 50 + 40 100 < 0.2
3 V 1 μV 0.005 0.002 120 + 80 50 + 40 100 < 0.2
10 V 10 μV 0.005 0.002 120 + 80 50 + 40 100 < 0.2
30 V 10 μV 0.005 0.002 120 + 80 50 + 40 50 < 0.2
100 V 0.1mV 0.005 0.002 120 + 80 50 + 40 50 < 0.2
300 V 0.1mV 0.005 0.002 120 + 80 50 + 40 50 < 0.2
1000 V 1 mV 0.005 0.002 120 + 80 50 + 40 15 < 0.2
1500 V [2] 1 mV 0.005 0.002 120 + 80 50 + 40 10 < 0.2
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%).
[2]:1500V range is an option.
  1. Output range: ± (10 mV~1150 V), 7 / 8-bit display digits can be set.
  2. 1500 V voltage output is optional Accessories,extend the voltage output range to ± (10 mV~1500 V).
  3. Protection function:short-circuit protection,overload protection.
 

5.2 DC Current Output [3]

Range Resolution Short Term Stability
 (% / min)
Accuracy (k=2)
(ppm of reading + ppm of range)
Maximum Burden Voltage (V) Ripple  ( % )
Class 0.05 Class 0.02 Class 0.05 Class 0.02
250 μA 0.1 nA 0.010 0.005 120 + 80 80 + 60 12 < 0.5
500 μA 0.1 nA 0.010 0.005 120 + 80 80 + 60 12 < 0.5
1 mA 1 nA 0.005 0.003 120 + 80 50 + 40 12 < 0.5
2 mA 1 nA 0.005 0.003 120 + 80 50 + 40 12 < 0.5
5 mA 1 nA 0.005 0.002 120 + 80 50 + 40 12 < 0.5
10 mA 10 nA 0.005 0.002 120 + 80 50 + 40 12 < 0.5
25 mA 10 nA 0.005 0.002 120 + 80 50 + 40 12 < 0.5
50 mA 10 nA 0.005 0.002 120 + 80 50 + 40 12 < 0.5
100 mA 0.1 μA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
200 mA 0.1 μA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
500 mA 0.1 μA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
1 A 1 μA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
2.5 A 1 μA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
5 A 1 μA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
10 A 10 μA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
20 A 10 μA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
50 A 10 μA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
100 A 0.1 mA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
250 A[3] 0.1 mA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
500 A[3] 0.1 mA 0.005 0.002 120 + 80 50 + 40 3 < 0.5
NOTES: [3] 250 A,500 A current range is optional Accessories.
  1. Output range: ± (5 µA~120 A ),7 / 8-bit display digits can be set.
  2. 600 A current output is optional Accessories, extend the current output range to ±(5 µA~600 A).
  3. Protection function:open-circuit protection, overload protection.
 

5.3 DC Small Signal Voltage Output[4]

Range Resolution Short Term Stability
 (% / min)
Accuracy (k=2)
(ppm of reading + ppm of range)
Maximum Burden Current (mA) Ripple ( % )
1 mV 10 nV 0.1 μVrms 120 + 0.3 μV - < 0.2
3 mV 10 nV 0.3 μVrms 120 + 1 μV - < 0.2
10 mV 0.1 μV 1 μVrms 120 + 3 μV - < 0.2
30 mV 0.1 μV 0.002 120 + 80 - < 0.2
100 mV 1 μV 0.002 120 + 80 - < 0.2
300 mV 1 μV 0.002 120 + 80 ≤ 10 < 0.2
1 V 10 μV 0.002 120 + 80 ≤ 10 < 0.2
4 V 10 μV 0.002 120 + 80 ≤ 10 < 0.2
NOTES: [4]When independently calibrating the indirect connected DC energy meter , it can be used as its current input (corresponding shunt voltage).
  1. Output range: ± ( 10 μV~4.4 V ),7 / 8-bit display digits can be set.
  2. The specification and current voltage ratio of the shunt can be set, and the output value can be displayed according to the voltage or current converted by the shunt.
  3. Protection function:short-circuit protection, overload protection.
 

5.4 Daily Reckoning Error

  1. Standard clock annual uncertainty of measurement of device:2×10-7
  2. The daily reckoning error supports two error display modes: s / d and ppm / ppb

5.5 DC Electric Energy Index

DC Power/Electric Energy Range Combination of DC voltage and DC current(or DC small-signal)
Accuracy Voltage uncertainty of measurement+ current uncertainty of measurement (or DC small-signal voltage uncertainty of measurement)
Electric Energy Pulse Standard Electric Energy Pulse Output High frequency full range value corresponds to 60 kHz;
Low frequency full range value corresponds to 6 Hz;
Pulse Output Frequency Output frequency jitter time<10 μs
Standard Electric Energy Pulse Input 2×10-7
Electric Energy Error Display Signal amplitude is 5 V,TTL level;
Can accept ≤200 kHz high-frequency pulse;
FH=60 kHz × power value÷ voltage range value ÷ current range value
FL=60 kHz × power value÷ voltage range value ÷ current range value
Electric Energy Error Display Auto display,resolution is 0.0001%
Difference At Different Epitope Position difference at different positions< ± 0.025%
 

5.6 Ripple Applied on DC Voltage U~

Voltage Range Ripple Adjustable Range
(Effective Value)
Accuracy(k = 2)
(%*RG)
Uncertainty Limit of Electric Energy Change Caused by Ripple(%*RD)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
3 V 0%~20.00% 0.05 0.02 0.05 0.02
10 V 0%~20.00% 0.05 0.02 0.05 0.02
30 V 0%~20.00% 0.05 0.02 0.05 0.02
100 V 0%~20.00% 0.05 0.02 0.05 0.02
300 V 0%~20.00% 0.05 0.02 0.05 0.02
1000 V 0%~20.00% 0.05 0.02 0.05 0.02
1500 V 0%~20.00% 0.05 0.02 0.05 0.02
  1. Ripple frequency: 100 Hz~1000 Hz, adjustment fineness: 1 Hz, Sine wave signal
  2. Ripple amplitude adjustment fineness: 0.01%, effective value, 7 / 8-bit display digits can be set.
 

5.7 Ripple Applied on DC Small-signal Voltage Iu~

Small-Signal Voltage Range Ripple Adjustable Range
(Effective Value)
Accuracy(k = 2)
(%*RG)
Uncertainty Limit of Electric Energy Change Caused by Ripple (%*RD)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
30 mV 0%~40.00% 0.05 0.02 0.05 0.02
100 mV 0%~40.00% 0.05 0.02 0.05 0.02
300 mV 0%~40.00% 0.05 0.02 0.05 0.02
1 V 0%~40.00% 0.05 0.02 0.05 0.02
4V 0%~40.00% 0.05 0.02 0.05 0.02
  1. Ripple frequency: 100 Hz~1000 Hz, adjustment fineness: 1 Hz, Sine wave signal
  2. Ripple amplitude adjustment fineness: 0.01%, effective value, 7 / 8-bit display digits can be set.
 

5.8 Ripple applied on DC current I~

Current Range Ripple Adjustable Range
(Effective Value)
Accuracy(k = 2)
(%*RG)
Uncertainty Limit of Electric Energy Change Caused by Ripple (%*RD)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
10 mA 0%~40.00% 0.05 0.02 0.05 0.02
20 mA 0%~40.00% 0.05 0.02 0.05 0.02
50 mA 0%~40.00% 0.05 0.02 0.05 0.02
100 mA 0%~40.00% 0.05 0.02 0.05 0.02
200 mA 0%~40.00% 0.05 0.02 0.05 0.02
500 mA 0%~40.00% 0.05 0.02 0.05 0.02
1 A 0%~40.00% 0.05 0.02 0.05 0.02
2 A 0%~40.00% 0.05 0.02 0.05 0.02
5 A 0%~40.00% 0.05 0.02 0.05 0.02
10 A 0%~40.00% 0.05 0.02 0.05 0.02
20 A 0%~40.00% 0.05 0.02 0.05 0.02
50 A 0%~40.00% 0.05 0.02 0.05 0.02
100 A 0%~40.00% 0.05 0.02 0.05 0.02
200 A 0%~40.00% 0.05 0.02 0.05 0.02
500 A 0%~20.00% [5] 0.05 0.02 0.05 0.02
NOTES[5]:When the maximum current is 100A, the ripple under 100A range is 0%~20.00%.
  1. Ripple frequency: 100 Hz~1000 Hz, adjustment fineness: 1 Hz, Sine wave signal
  2. Ripple amplitude adjustment fineness: 0.01%, effective value, 7 / 8-bit display digits can be set.
 

5.9 auxiliary power supply of the meter under test

DC Power Output Output Voltage 24 V / 48 V
Output Range 6 V~62.4V
Maximum Burden Current 300 mA per position
Uncertainty of Power Consumption Measurement Better than 0.1 VA
AC Power Output Output Voltage 220 V
Output Range 110 V~286 V
Maximum Burden Current 30 mA per position
Uncertainty of Apparent Power Consumption Measurement Better than 0.2 VA
Uncertainty of active power Consumption measurement Better than 0.2 W
  1. Each position has independent power consumption measurement function.
 

6. Ordering Information

TD1580 DC Energy Meters Testing Device

7. General Specifications

Power Supply AC (220±22) V,(50±2) Hz
Temperature Performance Working temperature:15°C~30°C;
Calibration temperature:18°C~28°C;
Storing temperature:-20°C~70°C
Humidity Performance Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C
Storing humidity:(20%~80%) R·H,no dewing
Interface RS232,RS485,RJ45,USB


 
Company Profile
 

TD1580 DC Energy Meters Testing Device

TD1580 DC Energy Meters Testing Device



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD1580 DC Energy Meters Testing Device pictures & photos
TD1580 DC Energy Meters Testing Device
US $77,500-137,500 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013