• TD1300 Precision DC Reference Meter
  • TD1300 Precision DC Reference Meter
  • TD1300 Precision DC Reference Meter
  • TD1300 Precision DC Reference Meter
  • TD1300 Precision DC Reference Meter
  • TD1300 Precision DC Reference Meter

TD1300 Precision DC Reference Meter

After-sales Service: Life Time
Warranty: 12 months Excellent After-sales Service
Power: Electricity
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD1300 Precision DC Reference Meter pictures & photos
TD1300 Precision DC Reference Meter
US $42,500-56,670 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD1300
LCD Display
With LCD Display
Customized
Non-Customized
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
45.00cm * 45.00cm * 32.00cm
Package Gross Weight
16.000kg

Product Description

TD1300 Precision DC Reference Meter
TD1300 Precision DC Reference Meter

1. Summary

TD1300 is a DC reference meter, which integrates DC reference voltmeter, DC reference ammeter, small-signal voltmeter, DC electric energy measurement, ripple measurement and other functions. It is applicable to calibration of DC current source, DC voltage source, DC power source and assessment of DC electric energy metering device.
 

2. Features

  1. Accuracy : class 0.01, class 0.02
  2. DC voltage measurement:10 mV ~ 1150 V.
  3. Direct measurement of DC current:10 μA ~ 120 A.
  4. Support the transducer to expand the current range to 500 A or more
  5. Small signal voltage measurement:0.1 mV ~ 12 V
  6. All electric quantity measurements support full-automatic range switching.
  7. Maximum DC ripple measurement bandwidth: 10 kHz.
  8. Comprehensive statistics and analysis of the measured electricity
  9. Standard electric energy pulse input / output
  10. Communication interface:RS232,LAN.
 

3. Applications

TD1300 Precision DC Reference Meter
  1. Assessment of electric energy metering devices:TD1300 can be used as a high-level electric energy standard meter to assess verification equipment for DC electrical energy meters and DC electrical energy reference meters. Its DC ripple test function is also applicable to the calibration of DC electric energy device with ripple detection function.
  2. Calibrate the electrical measurement standard source:Direct verification or calibration of DC voltage source, current source, power source, etc.
  3. Calibrate electrical measuring instruments:It can be used as a reference meter to verify or calibrate voltmeter, ammeter, ohmmeter, transmitter, sensor, etc. with a test power supply.

4. Characteristics


Wide range of current measurements
TD1300 Precision DC Reference Meter
  1. Direct current measurement:Use a pair of quick connect terminals to directly measure 10 μA~120 A wide range DC current.
  2. Current conversion measurement:The instrument is equipped with a special measuring interface for the transducer, which can simultaneously supply power to the transducer and measure its secondary signal. It can be connected to a precision current transducer (such as TH0540) to expand the current range to 500 A, 1 kA or even greater. The primary current of the measured transducer can be directly displayed by setting the ratio of the current transducer on the instrument.


 

DC comprehensive measurement
TD1300 Precision DC Reference Meter
  1. The instrument supports DC, DC ripple and other measurement modes, the DC ripple measurement bandwidth is up to 10 kHz.
  2. DC ripple measurement function is very suitable for verifying the verification device of electric energy meter with ripple output function.



 

Precise small signal voltage measurement
TD1300 Precision DC Reference Meter
TD1300 Precision DC Reference Meter
  1. It has a small signal voltage measurement function of ± (0.1 mV ~ 12 V), is equipped with ultra-low thermal potential terminals and test wires, and can withstand the overload signal of ± 100 V peak voltage at most.
  2. Application Scenario 1: It can be used to calibrate shunt or other I/V transformer with stable large current sources and precision current transducer.
  3. Application Scenario 2: With precision voltage measurement function, it can be used to assess the verification equipment for indirect connected DC electrical energy meters.
 

Power calculation function
TD1300 Precision DC Reference Meter
TD1300 Precision DC Reference Meter
  1. The instrument has the power calculation function. Users can connect voltage divider, shunt, transformer and other range extenders externally, set the ratio k and offset b, measure the secondary output signal x of the range extenders, and then calculate the actual value of the primary power to be measured according to the function f(x)=kx+b.
 

DC ripple, data statistics and analysis function
TD1300 Precision DC Reference Meter
S/N Function declaration
1 With DC ripple measurement function, it can measure ripple content in the range of 1 Hz~10 kHz.
It can display ripple waveform in real time, and measure RMS and P-P of ripple.
2 Data statistics and analysis: Calculate the maximum (Max), minimum (Min), peak to peak (P-P), average (Avg), standard deviation (S.dev), divergence (Div), etc. of the measured electricity.
3 Power trend chart test: During the test cycle, draw the curve of power change with time in real time.

5. Specifications

5.1 DC Voltage Measurement

Range Resolution Accuracy
(k=2) (ppm of reading + ppm of range) [1]
Temperature Coefficient @ (15~30)°C
(ppm of reading + ppm of range)/°C
Class 0.02 Class 0.01 Class 0.02 Class 0.01
100 mV 0.1 μV 80 + 6 μ 50+ 5 μV 3 + 0.5 μV 3.5 + 1.5 μV
300 mV 0.1 μV 60 + 8 μ 30 + 6 μV 3 + 0.6 μV 3 + 0.6 μV
1 V 1 μV 60 + 40 30 + 20 2.5 + 1 2.5 + 1
3 V 1 μV 60 + 40 30 + 20 2.5 + 1 2.5 + 1
10 V 10 μV 60 + 40 30 + 20 2.5 + 0.5 2.5 + 0.5
30 V 10 μV 60 + 40 30 + 20 2.5 + 1 2.5 + 1
100 V 100 μV 60 + 40 30 + 20 2.5 + 1 2.5 + 1
300 V 100 μV 60 + 40 30 + 20 3.5 + 1.5 3.5 + 1.5
1000 V 1 mV 60 + 40 30 + 20 3.5 + 1.5 3.5 + 1.5
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%).
  1. Measuring range:±(10 mV~1150 V),7-bit display,Manual/automatic range switching
  2. Input impedance:1 MΩ
 

5.2 DC Small Signal Voltage Measurement

Range Resolution Accuracy
(k=2) (ppm of reading + ppm of range) 
Temperature Coefficient @ (15~30)°C
(ppm of reading + ppm of range)/°C
0.02 0.01 0.02 0.01
1 mV 1 nV 80 + 0.4 μ 40 + 0.2 μV 5 + 0.04 μV 4 + 0.02 μV
10 mV 10 nV 80 + 1 μ 40 + 0.5 μV 5 + 0.1 μV 3 + 0.05 μV
100 mV 100 nV 80 + 20 40 + 10 5 + 2.0 3 + 1.0
1 V 1 μV 80 + 20 40 + 10 5 + 1.0 2 + 0.5
10 V 10 μV 80 + 20 40 + 10 5 + 1.0 2 + 0.5
  1. Measuring range:±(0.1 mV~12 V),7-bit display,Manual/automatic range switching
  2. Input impedance:>1 GΩ,Input protection:±100 Vpk.
 

5.3 DC Current Measurement

Range Resolution Accuracy
(k=2) (ppm of reading + ppm of range) 
Temperature Coefficient @ (15~30)°C
(ppm of reading + ppm of range)/°C
0.02 0.01 0.02 0.01
100 μA 0.1 nA 100 + 10 nA 50 + 5 nA 5 + 1 nA 3 + 0.5 nA
300 μA 0.1 nA 100 + 25 nA 50 + 15 nA 5 + 2 nA 3 + 1.5 nA
1 mA 1 nA 60 + 40 30 + 20 5 + 1.5 2.5 + 1
3 mA 1 nA 60 + 40 30 + 20 5 + 1.5 2.5 + 1
10 mA 10 nA 60 + 40 30 + 20 5 + 1.5 2.5 + 1
30 mA 10 nA 60 + 40 30 + 20 5 + 1.5 2.5 + 1
100 mA 100 nA 60 + 40 30 + 20 5 + 1.5 2.5 + 1
300 mA 100 nA 60 + 40 30 + 20 5 + 1.5 2.5 + 1
1 A 1 μ A 60 + 40 30 + 20 5 + 1.5 2.5 + 1
3 A 1 μA 60 + 40 30 + 20 5 + 1.5 2.5 + 1
10 A 10 μA 60 + 40 30 + 20 5 + 1.5 2.5 + 1
30 A 10 μA 60 + 40 30 + 20 5 + 1.5 2.5 + 1
100 A 100 μA 60 + 40 30 + 20 5 + 1.5 2.5 + 1
200 A [2] 100 μA 60 + 40 30 + 20 6 + 2.5 3.5 + 1.5
500 A [2] 100 μA 60 + 40 30 + 20 6 + 2.5 3.5 + 1.5
Note [2]: 200 A and 500 A range current are options, and a current transducer such as TH0540 must be selected to expand the range.
  1. Direct measurement range: ± (10 μ A~120 A), directly input through a pair of female sockets
  2. The upper limit of the current can be extended to 240 A or 600 A by matching the sensor.
  3. 7-bit display,Manual/automatic range switching
  4.  

5.4 DC Ripple Measurement

Frequency Band Range 1 Hz~10 kHz
Accuracy (k=2) 0.05%*RG,Valid values
 

5.5 Power/Electric Energy Measurement

DC Power/Electric Energy Measuring Range Combination of DC voltage and DC current
Accuracy Accuracy of DC voltage+ Accuracy of DC current (or small signal voltage)
Electric Energy Pulse Standard Electric Energy Pulse Input Directly receive the photoelectric pulse of electric energy of the tested meter
Standard Electric Energy Pulse Output Signal amplitude is 5V, TTL level
FH=60 kHz × Power value ÷ voltage range value ÷ current range value
FL=60 kHz × Power value ÷ voltage range value ÷ current range value ÷ 10000  
Electric Energy Error Display Automatic display, resolution 0.001%
 

6. Ordering Information

TD1300 Precision DC Reference Meter

 

7. General Specifications

Power Supply AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz,Maximum power consumption:100 VA
Temperature Performance Working temperature:15°C~35°C;
Storage temperature:-10°C~50°C
Humidity Performance Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C
Storage humidity:(20%~80%) R·H,No condensation
Interface RS232,RJ45
 
 
Company Profile
 

TD1300 Precision DC Reference Meter

TD1300 Precision DC Reference Meter



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD1300 Precision DC Reference Meter pictures & photos
TD1300 Precision DC Reference Meter
US $42,500-56,670 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013