• TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
  • TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
  • TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
  • TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
  • TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
  • TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator

TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator

Power: Electricity
LCD Display: With LCD Display
Customized: Non-Customized
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator pictures & photos
TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
US $7,000-10,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD3220
Accuracy
Class 0.05
3PH Voltage Measurement
0~480 V
3PH Current Measurement (direct)
50 mA~ 12A
3PH Current Measurement (clamp)
100 mA~ 120 A
Power Supply
AC (220 ± 22) V, (50 ± 2) Hz
Communication Interface
RS232
Transport Package
Package for Exporting
Specification
About 5 kg
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
60.00cm * 50.00cm * 40.00cm
Package Gross Weight
10.000kg

Product Description

TD3220 Portable AC Sampling And
Transmitter On-site Calibrator
TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator

1. Summary
TD3220 is a portable instrument that integrates functions such as three-phase power standard meter, DC small signal standard meter, wiring identification, harmonic analysis, waveform display, phase vector diagram, data management, etc. It is designed for Class 0.05 specifications and allows for real load calibration of AC sampling devices and transmitters in power systems.
 

2. Features
  1. Three-phase voltage measurement range: 0~ 480 V.
  2. Three-phase current measurement range: 50 mA~ 12 A (direct measurement), 100 mA~ 120 A (clamp measurement).
  3. Large LCD touch screen display, intuitive value display and convenient operation.
  4. The power supply supports wide voltage mains input or battery power supply.
  5. Equipped with RS232 interface, which can realize data storage and remote transmission.
  6. Small size, light weight and easy to carry.
 

3. Application

TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator

TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
 Real Load Calibration of AC Sampling Devices (Standard Meter Method)
TD3220 supports direct measurement of three-phase voltage, ranging from 10 V to 480 V, direct measurement of three-phase current from 0.05 A to 12 A, and three-phase current clamp measurement from 0.1 A to 120 A;
Application 1 (direct current measurement)
Suitable for calibrating single-phase/three-phase voltage sources, current sources, and power sources of level 0.2 and below in the laboratory or on site.
Application 2 (Clamp measuring current)
In the past, when testing on-site AC sampling devices, it was usually necessary to wait for a power outage for maintenance before disconnecting the circuit, stringing a standard ammeter into the loop for testing, or removing the tested meter to the laboratory for testing using the standard source method.
When using a clamp meter to detect current, users can clamp the current wire into the clamp instead of cutting the circuit short, and then measure it online in real time. This instrument completes on-site inspections more quickly and conveniently, and can meet the requirements for daily inspection of the operating status of instruments.

TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
 
☆ Real Load Calibration of AC and DC Transmitter
  1. It has the secondary DC signal measurement function of the transmitter and supports a maximum DC 12V or 24 mA signal input.
  2. It measures the primary/secondary signal of the transmitter running online to complete the test of basic error, output ripple, and response time.

TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
 
☆ Real Load Calibration of CT Ratio
  1. It can realize CT transformation ratio test. The instrument measures the primary signal of the CT through a large current clamp, and measures the secondary signal of the CT through a small current clamp, and calculates the CT transformation ratio and the phase relationship between the primary and secondary currents. This determines whether the CT operating status is good.
 

5. Instrument Appearance

TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator

 Front Panel
N0. Function
1 Power Cord Socket: mains power supply or lithium battery charging.
2 RS232 Terminal: connecting to a computer to transfer data through management software.
3 Power Supply Switch
4 Clamp-type Current Terminal Block: measuring current from 0.1 A to 120 A.
5 Three-phase Voltage Terminal Block: A wide range of voltage measurement from 10 V to 480 V can be achieved with one connection.
6 Three-phase Current Terminal Block: measuring current from 0.05 A to 12 A.
7 LCD Touch Color Screen: intuitive display of various electrical parameters and full touch operation, greatly improving the ease of use of the instrument.
8 DC Measurement Terminal Block: used for secondary signal measurement of the transmitter.

6. Characteristics

TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
☆ On-site Portable Design
  1. It adopts imported protective box, which is light weight, small in size and good in protection, and is suitable for carrying to on-site work.
  2. It can be powered by 220 V mains power or the built-in large-capacity lithium battery, which is convenient for application in complex sites.
  3. It has a built-in large-capacity memory, which can quickly record the test data of the inspected equipment on site, up to thousands of pieces, and can be transferred to the supporting computer management software after the calibration work is completed.

TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator

 
☆ Good Human-Machine Functionality
  1. Equipped with a large LCD touch color screen, the value display is intuitive and the operation is very convenient.
  2. Multiple types of measured power, errors of the equipment being tested, and phasor diagrams can be displayed on the same screen.

7. Specifications

7.1 Three-phase Voltage/Current Measurement

Three Phase Measurement Method Range Resolution Measurement Uncertainty
( k = 2 )
( ppm*RD+ppm*RG) [1]
AC Voltage
ACV
Direct Measurement 110 V 1 mV 300 + 200
220 V 1 mV 300 + 200
480 V 1 mV 300 + 200
AC Current
ACI
Direct Measurement 1 A 10 μA 300 + 200
10 A 100 μA 300 + 200
Clamp Measurement 1 A 10 μA 0.2%*RG
5 A 10 μA 0.2%*RG
20 A 100 μA 0.2%*RG
100 A 1 mA < 50 A:0.2%*RG;≥ 50 A:0.5%*RG
Note[1]:RD is the reading value, RG is the range value, the same below.
  1. Voltage measurement range: 10 V ~ 480 V, 6-digit decimal display
  2. Current measurement range: 0.05 A~12 A @ direct measurement; 0.1 A~120 A @ clamp measurement
  3. Frequency range: 45 Hz ~ 65 Hz, measurement uncertainty: 0.01 Hz
  4. Phase range: 0.00°~359.99°, measurement uncertainty: 0.05° (direct measurement); 0.2° (clamp measurement)

7.2 Three-phase Power Measurement

Power Parameters Measurement Uncertainty
 ( k = 2 )
Direct Measurement Clamp Measurement
Active Power |cosφ| ≥0.5 0.05%*FS[2] 0.2%*FS[2]
Reactive Power |sinφ| ≥0.5 0.1%*FS[2] 0.5%*FS[2]
Apparent Power 0.1%*FS[2] 0.5%*FS[2]
Power Factor 0.0005 0.005
Note[2]:FS=Voltage range value × current range value.
  1. Power factor measurement range:-1.0000…0.0000…1.0000

7.3 DC Small Signal Measurement (Transmitter Test)

Range Measuring Range Measurement Uncertainty ( k = 2 ) Ripple
Range
Ripple Measurement Uncertainty
1 V ± ( 0~1.2 ) V 0.01%*RG 0~500 mV 1%*RG
10 V ± ( 0~12 ) V 0.01%*RG
2 mA ±( 0~2.4) mA 0.01%*RG 0~1.2 mA 1%*RG
20 mA ± ( 0~24 ) mA 0.01%*RG
 

8. General Specifications

Power Supply Mains power: AC (220 ± 22) V, (50 ± 2) Hz;
Lithium battery power supply:continuous working for 8 hours
Maximum Power Consumption 30 VA
Temperature Performance Working temperature: 0°C~50°C;
Storage temperature: -20°C~70°C
Humidity Performance Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C
Storage humidity: (20%~80%) R·H, no condensation
Altitude < 3000 m
Weight About 5 kg
Communication Interface RS232
Dimensions 365 mm(W) × 270 mm(D) × 170 mm(H)
Company Profile
 

TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator

TUNKIA TD3220 Portable AC Sampling And Transmitter On-site CalibratorTUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator pictures & photos
TUNKIA TD3220 Portable AC Sampling And Transmitter On-site Calibrator
US $7,000-10,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013