• TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology
  • TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology
  • TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology
  • TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology
  • TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology
  • TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology

TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology

After-sales Service: Life Time
Warranty: 12 Months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology pictures & photos
TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology
US $1,000-10,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Summary
  • Features
  • Application
  • Appearance
  • Specifications
  • Company Profile
Overview

Basic Info.

Model NO.
TD1850
Power
Electricity
Voltage Output
Max. 1100V
Current Output
Max. 22A
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
Class 0.05 / Accuracy 5%
DC voltage output
20 mV ~ 1100 V
DC current output
2 μA ~ 22 A(33 A is optional)
AC voltage output
20 mV ~ 1100 V
AC current output
200 μA ~ 22 A(33 A is optional)
Sinusoidal wave frequency
45 Hz ~ 1100 Hz
Simulated DC resistance
10 Ω ~ 220 MΩ
Transport Package
Package for Exporting
Specification
475 mm(W) * 400 mm (D) * 190 mm (H), 18Kg
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
100.00cm * 100.00cm * 100.00cm
Package Gross Weight
30.000kg

Product Description

TD1850 Multi-function Calibrator 
TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology
Summary

 

TD1850 is a multi-function calibrator, integrates AC\DC voltage source, AC\DC current source, DC resistance source, etc. The accuracy class is 0.05. It's applied to calibrating 3.5 digits multimeter, voltmeter, ammeter, ohmmeter, power meter.
Features

 

DC voltage output: 20 mV ~ 1100 V
DC current output: 2 μA ~ 22 A(33 A is optional)
AC voltage output: 20 mV ~ 1100 V
AC current output: 200 μA ~ 22 A(33 A is optional)
Sinusoidal wave frequency: 45 Hz ~ 1100 Hz
Simulated DC resistance: 10 Ω ~ 220 MΩ. 
2 MHz square wave frequency output
Remote adjustment (optional)
Clamp meter calibration (optional)
Transducer calibration(optional) 
Application

 

TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology
Calibrate AC\DC electrical measuring instruments
TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology
DCV output: 20 mV ~ 1100 V
DCI output: 2 μA ~ 22 A\33 A
ACV output: 20 mV ~ 1100 V, 45 Hz ~ 1100 Hz
ACI output: 200 μA ~ 22 A\33 A, 45 Hz ~ 1100 Hz
RES output: 10 Ω ~ 220 MΩ
Frequency output: 1 Hz ~ 2 MHz
Calibrate digital multimeter, AC/DC voltmeter, AC/DC ammeter, DC ohmmeter, frequency meter.
 Calibrate clamp ammeter (optional)
TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology
Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters.
 
 Calibrate AC/DC Transducer (optional)
TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology
  1. DC small-signal measurement. (Vmax: 12 V, Imax: 24 mA)
  2. Calibrate the proportional error of AC/DC voltage/current transducer. 
 
Appearance

 

Front\Side Panel
TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology
Item Description
1 LCD touch screen.
2 Operation panel.
3 Simulated DC resistance output terminals.
4 AC/DC voltage output terminals.
5 AC/DC current output terminals.
6 Handle: used for carrying instruments.
7 Input terminals for DC transducer. 
 
Rear panel
TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology
Item Description
1 Pulse frequency output terminals.
2 Remote box interface.
3 RS232 communication interface.
4 Chassis ground binding post.
5 AC 220V power interface.
6 Cooling vents.

5. Characteristics

Wide output range
TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology


 
  • Multiple output\adjustment methods
TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology
"Direct output" mode: the value output can be set directly by physical key or touch screen.
 
TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology
Calibration of the analog pointer meter usually needs to test scale by scale, especially "differences between rising and falling" (the change caused by the rise and fall of the calibration point).
Remote box can realize the coarse and fine adjustment of current or voltage.
 
Specifications

6.1 DC Voltage/Current Output

Range Resolution Stability (±%/min) Accuracy
 ±(ppm*RD+ppm*RG)[1]
Max Burden (mA) Ripple Factor(%)
200 mV 1 μV 0.01 300 + 200 300 <0.5
2 V 10 μV 0.01 300 + 200 500 <0.5
10 V 100 μV 0.01 300 + 200 500 <0.5
30 V 100 μV 0.01 300 + 200 800 <0.5
100 V 1 mV 0.01 300 + 200 300 <0.5
300 V 1 mV 0.01 300 + 200 100 <0.5
600 V 1 mV 0.01 300 + 200 50 <0.5
1000 V 10 mV 0.01 300 + 200 30 <0.5
 
Ranges Resolution Stability
(±%/min)
Accuracy
 ±(ppm*RD+ppm*RG)
Compliance Voltage (V) Ripple Factor(%)
20 μA 100pA 0.01 300 + 200 10 <0.5
200 μA 1 nA 0.01 300 + 200 9 <0.5
2 mA 10 nA 0.01 300 + 200 9 <0.5
20 mA 100 nA 0.01 300 + 200 9 <0.5
200 mA 1 μA 0.01 300 + 200 9 <0.5
2 A 10 μA 0.01 300 + 200 3.5 <0.5
10 A 100 μA 0.01 300 + 200 2.5 <0.5
20 A (30 A)[2] 100 μA 0.01 300 + 200 2.5 <0.5
Note[1]: RD is the reading value, RG is the range value;
Note[2]: The 30 A range is optional. 
  1. Voltage output range: 20 mV ~ 1100 V
  2. Current output range: 2 μA ~ 22 A\33 A
  3. Protections: voltage source short-circuit protection, current source open-circuit protection, overload protection

6.2 AC Voltage/Current Output

Range Resolution Stability
 (±%/min)
Accuracy
 ±(ppm*RD+ppm*RG)
Max Burden (mA) Harmonic (%)
200 mV 1 μV 50 μV 300 + 60 μV 500 <1.0
2 V 10 μV 0.01 300 + 200 500 <0.5
10 V 100 μV 0.01 300 + 200 800 < 0.5
30 V 100 μV 0.01 300 + 200 800 < 0.5
100 V 1 mV 0.01 300 + 200 300 < 0.5
300 V 1 mV 0.01 300 + 200 100 < 0.5
600 V 1 mV 0.01 300 + 200 50 < 0.5
1000 V 10 mV 0.01 300 + 200 30 < 0.5
 
Range Resolution Stability
 (±%/min)
Accuracy
 ±(ppm*RD+ppm*RG)
Compliance Voltage (V) Harmonic (%)
2 mA 10 nA 0.6 μA 300 +0.6 μA 50 < 0.5
20 mA 100 nA 0.01 300 + 200 50 < 0.5
200 mA 1 μA 0.01 300 + 200 50 < 0.5
1 A 10 μA 0.01 300 + 200 15 < 0.5
2 A 10 μA 0.01 300 + 200 10 < 0.5
5 A 10 μA 0.01 300 + 200 5 < 0.5
20 A(30 A)[1] 100 μA 0.01 300 + 200 2.5 < 0.5
Note [1]: 30 A range is optional.
  1. Voltage output range: 20 mV ~ 1100 V
  2. Current output range: 2 μA ~ 22 A\33 A
  3. Voltage and current output frequency: 45 Hz ~ 1100 Hz
  4. Protections: voltage source short-circuit protection, current source open-circuit protection, overload protection

6.3 Simulated DC Resistance

Range Resolution Accuracy
 ±(ppm*RD+ppm*RG)
Allowable Current
100 Ω 1 mΩ 300 + 200 1mA ~ 80 mA
300 Ω 1 mΩ 300 + 200 1mA ~ 80 mA
1 kΩ 10 mΩ 300 + 200 100μA ~ 8 mA
3 10 mΩ 300 + 200 100μA ~ 8 mA
10 kΩ 100 mΩ 300 + 200 10μA ~ 0.8 mA
30 kΩ 100 mΩ 300 + 200 10μA ~ 0.8 mA
100 kΩ 1 Ω 300 + 200 10μA ~ 0.8 mA
300 kΩ 1 Ω 300 + 200 1μA ~ 80 μA
1 MΩ 10 Ω 300 + 200 1μA ~ 80 μA
10 MΩ 100 Ω 600 + 400 100nA ~ 8 μA
100 MΩ 1000 Ω 3000 + 2000 10nA ~ 0.8 μA
200 MΩ 1000 Ω 3500 + 2500 10nA ~ 0.8 μA
  1. Output range: 10 Ω ~ 220 MΩ
  2. Over-current and reverse connection protection

6.4 Sinusoidal Wave Frequency Output

Output Range[1] Resolution Accuracy
45.0000 Hz ≤ F ≤ 99.9999 Hz 0.0001 Hz ±0.01%
100.000 Hz ≤ F ≤ 999.999 Hz 0.001 Hz ±0.01%
1000.00 Hz ≤ F ≤ 1100.00 Hz 0.01 Hz ±0.01%
Note [1]: The output mode is AC voltage or AC current.
 

6.5 Pulse Frequency Output

Range[1] Resolution Accuracy Shake
1.000 00 Hz ≤ F ≤ 9.999 99 Hz 10 μHz ±(20 ppm*RD + 20 μHz) <20 ns
10.000 0 Hz ≤ F ≤ 99.999 9 Hz 0.1 mHz
100.000 Hz ≤ F ≤ 999.999 Hz 1 mHz
1.000 00 kHz ≤ F ≤ 9.999 99 kHz 10 mHz
10.000 0 kHz ≤ F ≤ 99.999 9 kHz 0.1 Hz
100.000 kHz ≤ F ≤ 999.999 kHz 1 Hz
1.000 00 MHz ≤ F ≤ 2.000 00 MHz
  1. Hz
Note [1]: The output type is TTL level.
 

6.6 DC Small-signal Measurement (optional)

Type Range Measurement range Accuracy
DCV 1 V ±(0 ~ 1.2) V ±(0.006%*RD + 0.004%*RG)
10 V ±(0 ~ 12) V ±(0.006%*RD + 0.004%*RG)
DCI 2 mA ±(0 ~ 2.4) mA ±(0.006%*RD + 0.004%*RG)
20 mA ±(0 ~ 24) mA ±(0.006%*RD + 0.004%*RG)
 

7. General Specifications

Power supply AC (220±22) V,(50±2) Hz
Maximum power consumption 600 VA
Warm up time Twice the time since last warmed up, to a maximum of 30 minutes.
Temperature performance Operating temperature: 0°C ~ 40°C
Calibration temperature: 18°C ~ 28°C
Storage temperature: -20°C ~ 70°C
Humidity performance Operating humidity: <80% @ 30°C,<70% @ 40°C
Storage humidity: (20%~80%) R·H,No condensation
Communication interface RS 232
Dimensions 475 mm(W) × 400 mm (D) × 190 mm (H), excluding handles and feets.
Weight About 18 kg
 
Company Profile

TUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrologyTUNKIA TD1850 Portable High Accuracy AC/DC Current Source and Voltage Source for calibrator metrology



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology pictures & photos
TUNKIA TD1850 Portable High Accuracy  AC/DC Current Source and Voltage Source for calibrator metrology
US $1,000-10,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013