• TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance
  • TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance
  • TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance
  • TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance
  • TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance
  • TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance

TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance

After-sales Service: Life Time
Warranty: 12 Months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance pictures & photos
TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance
US $1,000-16,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
TD1470
Power
Electricity
LCD Display
Without LCD Display
Customized
Non-Customized
DC Current Measurement
1 mA ~ 11 A
Resistance Simulation range
100 μΩ ~ 11 MΩ
Measurement Uncertainty
100 ppm
Test Modes
two-wire and four-wire
Dispaly
Large-size LCD touch screen
Transport Package
Package for Exporting
Specification
100 mm(W) *100 mm(D) *50 mm(H), 0.5Kg
Trademark
TUNKIA
Origin
China
Production Capacity
100

Packaging & Delivery

Package Size
60.00cm * 40.00cm * 40.00cm
Package Gross Weight
12.000kg

Product Description

 
TD1470 Single and Double Arm Bridge Calibration Device
TUNKIA TD1470 Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance
1. Summary
TD1470 is an instrument that can accurately simulate a wide range of DC standard resistance. It can realize the verification and calibration of single-arm bridges, double-arm bridges, high-precision DC resistance meters and digital micro-ohmmeters.
 
2. Features
  1. DC current measurement range: 1 mA ~ 11 A
  2. Resistance simulation range: 100 μΩ ~ 11 MΩ
  3. Best measurement uncertainty of resistance: 100 ppm
  4. Two-wire and four-wire resistance modes
  5. RS232 interface
  6. Large-size LCD touch screen

3. Application
  1. Calibrate single-arm bridge with class 0.05 and below
  2. Calibrate DC resistance meters of class 0.05 and below
  3. Calibrate temperature measurement bridges of class 0.05 and below
4. Characteristics
TUNKIA TD1470 Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance
 Analog resistance output
  1. The four-wire wiring method can effectively eliminate the measurement error caused by the resistance of the test wire, and the measurement accuracy is higher;
  2. Compared with physical resistor boxes, analog resistors have the following advantages:
(1) The resistance value is continuously adjustable, with better adjustment fineness and better sensitivity;
(2) There is no influence from switching error, residual resistance error, contact resistance error, etc., and the measurement data is accurate and reliable;
(3) When the physical resistor is overloaded, it will cause the resistance to change value, and in severe cases, it may even cause the resistor to be damaged. TD1470 has current overload capability and impact resistance, and has been completely tested for electrostatic protection and electromagnetic compatibility. It has good protection performance and high reliability.
  1. TD1470 has a self-calibration function to ensure long-term accuracy and stability of the value.
TUNKIA TD1470 Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance
Statistical analysis of test data
S/N Function
1 Integration period: The integration period can be set in the range of 0.5 s ~ 20 s (default 1 s);
2 Statistical analysis: Real-time recording and statistical test data, including current Max, Min, Avg, Span, Stab, S. dev, Time, test times N, etc.

6. Specifications
6.1 Low Value Resistor Simulation
Range Fineness Adjustment Measurement Uncertainty (k=2, ppm*RD+μΩ)[1] Input Current[2]
24h
( 23 ± 1 )°C
90days
( 23 ± 5 )°C
1year
( 23 ± 5 )°C
1 mΩ 10  50 + 0.5 75 + 0.5 100 + 0.5 1 A~10 A
10 mΩ 100  50 + 1 75 + 1 100 + 1 0.5 A~5 A
100 mΩ 1 μΩ 50 + 3 75 + 3 100 + 3 0.3 A~5 A
1 Ω 10 μΩ 50 + 15 75 + 15 100 + 15 0.05 A~5 A
10 Ω 100 μΩ 50 + 150 75 + 150 100 + 150 10 mA~300 mA
100 Ω 1  50 + 1500 75 + 1500 100 + 1500 1 mA~30 mA
Note [1]: RD is the reading value, the same below;;
[2] When the current and resistance exceed the range, the resistance value will bring additional error
  1. Resistance Simulation Range: (10%~110%)*RG,6-digit display
  2. Wiring Method: 4-wire
  3. Current Input Range: 1 mA ~ 11 A
  4. Range Switching: manual/automatic shifting

6.2 Medium and High Value Resistance Simulation
Range Fineness Adjustment Measurement Uncertainty ( k=2, ppm*RD+Ω ) Input Current
24h
(23±1)°C
90days
(23±5)°C
1year
(23±5)°C
100 Ω 1 mΩ 50 + 0.002 75 + 0.002 100 + 0.002 1 mA~80 mA
1 kΩ 10 mΩ 45 + 0.01 50 + 0.01 90 + 0.01 1 mA~12 mA
10 kΩ 100 mΩ 45 + 0.1 50 + 0.1 90 + 0.1 100 μA~2 mA
100 kΩ 1 Ω 45 + 1.0 50 + 1.0 90 + 1.0 10 μA~0.2 mA
1 MΩ 10 Ω 50 + 10 75 + 10 100 + 10 1 μA~20 μA
10 MΩ 100 Ω 100 + 100 150 + 100 200 + 100 250 nA~2 μA
  1. Resistance Simulation Range: (10%~110%)*RG,6-digit display
  2. Wiring Method: 4-wires /2-wires
  3. Current Input Range: 250 nA ~ 80 mA
  4. Range Switching: manual/automatic shifting

7. General Specifications
Power Supply AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz;
Warm-up Time Not less than 1 hour, and the warm-up time again after shutting down in the middle should not be less than 2 times the shutdown time;
Maximum Power Consumption 150 VA
Temperature Performance Working temperature: 18 °C ~ 28 °C;
Storage temperature: -10 °C ~ 50 °C;
Humidity Performance Working humidity: ( 20 % ~ 80% ) R·H, non-condensing;
Storage humidity: < 85% R·H, no condensation;
Altitude < 3000 m
Weight Approx 10 kg
Communication Interface RS 232,USB,IP
Dimension 400 mm ( W ) × 265 mm ( D ) × 190 mm ( H ) (without feet and handles)

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance pictures & photos
TUNKIA TD1470  Digital Single and Double Arm Bridge Calibration Device DC Standard Analog Resistance
US $1,000-16,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013