☆ Calibrate AC\DC electrical measuring instruments |
|
☆ Calibrate AC\DC power meters |
Calibrate DC power meter, real power meter, phantom power meter, apparent power meter, power frequency phase meter and power factor meter.
|
☆ Calibrate clamp ammeter (optional) |
Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters.
|
☆ Calibrate AC/DC Transducer (optional) |
DC small-signal measurement. (Vmax: 12 V, Imax: 24 mA)
Calibrate the proportional error of AC/DC voltage/current transducer.
|
☆ Front\Side Panel | |
Item | Description |
1 | LCD touch screen. |
2 | Pulse frequency output terminal. |
3 | Input terminals for transducer. |
4 | Operation panel. |
5 | Foldable feets. |
6 | AC/DC current output terminals. |
7 | AC/DC voltage output terminals. |
8 | Simulated DC resistance output terminals. |
☆ Rear panel | |
Item | Description |
1 | Remote box interface. |
2 | RS232 communication interface. |
3 | Cooling vents. |
4 | Chassis ground binding post. |
5 | AC 220V power interface. |
6 | Foldable feets. |
7 | Handle: used for carrying instruments. |
☆ Wide output range |
☆ Multiple output\adjustment methods |
"Direct output" mode: the value output can be set directly by physical key or touch screen.
|
Calibration of the analog pointer meter usually needs to test scale by scale, especially "differences between rising and falling" (the change caused by the rise and fall of the calibration point).
Remote box can realize the coarse and fine adjustment of current or voltage.
|
Range | Resolution | Stability | Accuracy[1] | Max Burden (mA) | Ripple Factor (%) |
|
24 hours (23±1)°C |
90 days (23±5)°C |
1 year (23±5)°C |
||||
±(ppm*output + μV) | ||||||
100 mV | 1 μV | 40 + 5 | 64 + 10 | 80 + 10 | 300 | <0.5 |
300 mV | 1 μV | 40 + 5 | 64 + 10 | 80 + 10 | 300 | <0.5 |
1 V | 10 μV | 40 + 10 | 64 + 15 | 80 + 15 | 300 | <0.5 |
3 V | 10 μV | 40 + 10 | 64 + 15 | 80 + 15 | 300 | <0.5 |
10 V | 100 μV | 40 + 100 | 64 + 150 | 80 + 150 | 600 | <0.5 |
30 V | 100 μV | 40 + 150 | 64 + 150 | 80 + 150 | 800 | <0.5 |
100 V | 1 mV | 40 + 1500 | 64 + 1500 | 80 + 1500 | 300 | <0.5 |
300 V | 1 mV | 40 + 1500 | 64 + 1500 | 80 + 1500 | 120 | <0.5 |
1000 V | 10 mV | 40 + 5000 | 64 + 5000 | 80 + 5000 | 40 | <0.5 |
Note[1]:When the output is negative, the floor uncertainly is double. For example, when the output is 1 V, the accuracy is (80 ppm × 1 V + 30 μV); |
Range | Resolution | Stability | Accuracy [1] | Compliance Voltage (V) | Ripple Factor (%) | |
24 hours (23±1)°C |
90 days (23±5)°C |
1 year (23±5)°C |
||||
±(ppm*RD + μA) | ||||||
30 μA | 100 pA | 96 + 0.02 | 108 + 0.02 | 120 + 0.02 | 11 | <0.5 |
100 μA | 1 nA | 96 + 0.04 | 108 + 0.04 | 120 + 0.04 | 11 | <0.5 |
300 μA | 1 nA | 96 + 0.04 | 108 + 0.04 | 120 + 0.04 | 11 | <0.5 |
1 mA | 10 nA | 96 + 0.08 | 108 + 0.08 | 120 + 0.08 | 11 | <0.5 |
3 mA | 10 nA | 96 + 0.08 | 108 + 0.08 | 120 + 0.08 | 11 | <0.5 |
10 mA | 100 nA | 96 + 0.8 | 108 + 0.8 | 120 + 0.8 | 11 | <0.5 |
30 mA | 100 nA | 96 + 0.8 | 108 + 0.8 | 120 + 0.8 | 11 | <0.5 |
100 mA | 1 μA | 96 + 8 | 108 + 8 | 120 + 8 | 11 | <0.5 |
300 mA | 1 μA | 96 + 24 | 108 + 24 | 120 + 24 | 4 | <0.5 |
1 A | 10 μA | 96 + 80 | 108 + 80 | 120 + 80 | 3.5 | <0.5 |
3 A | 10 μA | 96 + 80 | 108 + 80 | 120 + 80 | 4 | <0.5 |
10 A | 100 μA | 96 + 800 | 108 + 800 | 120 + 800 | 3.5 | <0.5 |
20 A(30 A)[2] | 100 μA | 96 + 800 | 108 + 800 | 120 + 800 | 2.8 | <0.5 |
Note [1]: When the output is negative, the floor uncertainly is double; Note [2]: 30 A range is optional. |
Range | Resolution | Accuracy | Allowable Current | |
90days(23±5)°C | 1year(23±5)°C | |||
±(ppm*output + Ω) | ||||
0 Ω | - | 5 mΩ | 5 mΩ | 1mA~ 300mA |
10 Ω | 100μΩ | 240 + 0.015 | 300 + 0.015 | 1mA~ 150 mA |
30 Ω | 100μΩ | 240 + 0.015 | 300 + 0.015 | 1mA~ 150 mA |
100 Ω | 1 mΩ | 120 + 0.015 | 150 + 0.015 | 1mA~ 80 mA |
300 Ω | 1 mΩ | 120 + 0.03 | 150 + 0.03 | 1mA~ 40 mA |
1 kΩ | 10 mΩ | 80 + 0.1 | 100 + 0.1 | 1mA~ 20 mA |
3kΩ | 10 mΩ | 80 + 0.2 | 100 + 0.2 | 0.1mA~ 6mA |
10 kΩ | 100 mΩ | 80 + 1 | 100 + 1 | 0.1mA~ 2mA |
30 kΩ | 100 mΩ | 80 + 2 | 100 + 2 | 10μA~ 600 μA |
100 kΩ | 1 Ω | 80 + 10 | 100 + 10 | 10μA~ 200 μA |
300 kΩ | 1 Ω | 80 + 20 | 100 + 20 | 1μA~ 60 μA |
1 MΩ | 10 Ω | 80 + 100 | 100 + 100 | 1μA~ 20 μA |
3 MΩ | 10 Ω | 80 + 300 | 100 + 300 | 0.25μA~ 6 μA |
10 MΩ | 100 Ω | 240 + 1k | 300 + 1k | 0.25μA~ 2 μA |
30 MΩ | 100 Ω | 400 + 3k | 500 + 3k | 25nA~600nA |
100 MΩ | 1kΩ | 1600 + 80k | 2000 + 80k | 25nA~200nA |
200 MΩ | 1kΩ | 4000 + 100k | 5000 + 100k | 2.5nA~ 45nA |
Range | Resolution | Frequency (Hz) | Accuracy | Max Burden (mA) [Source internal resistance] |
Harmonic (%) | |
90 days (23±5)°C |
1 year (23±5)°C |
|||||
±(ppm*RD + mV) | ||||||
30 mV | 100 nV | 45≤F≤1k | 360 + 0.03 | 400 + 0.03 | [1Ω] | <0.5 |
1k<F≤1.5k | 540 + 0.03 | 600 + 0.03 | <0.5 | |||
100 mV | 1 μV | 45≤F≤1k | 360 + 0.03 | 400 + 0.03 | [1Ω] | <0.5 |
1k<F≤1.5k | 540 + 0.03 | 600 + 0.03 | <0.5 | |||
300 mV | 1 μV | 45≤F≤1k | 270 + 0.05 | 300 + 0.05 | 100 | <0.5 |
1k<F≤1.5k | 450 + 0.05 | 500 + 0.05 | <0.5 | |||
1 V | 10 μV | 45≤F≤1k | 270 + 0.2 | 300 + 0.2 | 300 | <0.5 |
1k<F≤1.5k | 450 + 0.2 | 500 + 0.2 | <0.5 | |||
3 V | 10 μV | 45≤F≤1k | 360 + 0.2 | 400 + 0.2 | 300 | <0.5 |
1k<F≤1.5k | 450 + 0.2 | 500 + 0.2 | <0.5 | |||
10 V | 100 μV | 45≤F≤1k | 270 + 2 | 300 + 2 | 500 | <0.5 |
1k<F≤1.5k | 450 + 2 | 500 + 2 | <0.5 | |||
30 V | 100 μV | 45≤F≤1k | 360 + 2 | 400 + 2 | 800 | <0.5 |
1k<F≤1.5k | 450 + 2 | 500 + 2 | <0.5 | |||
100 V | 1 mV | 45≤F≤1k | 270 + 20 | 300 + 20 | 400 | <0.5 |
1k<F≤1.5k | 450 + 20 | 500 + 20 | <0.5 | |||
300 V | 1 mV | 45≤F≤1k | 360 + 20 | 400 + 20 | 120 | <0.5 |
1k<F≤1.5k | 450 + 20 | 500 + 20 | <0.5 | |||
1000 V | 10 mV | 45≤F≤1k | 270 + 200 | 300 + 200 | 40 | <0.5 |
1k<F≤1.5k | 450 + 200 | 500 + 200 | <0.5 |
Range | Resolution | Frequency (Hz) |
Accuracy | Compliance Voltage (V) | Harmonic (%) | |
90 days (23±5)°C |
1 year (23±5)°C |
|||||
±(ppm*RD + μA) | ||||||
300 μA | 1 nA | 45≤F≤1k | 360 + 0.12 | 400 + 0.12 | 50 | <0.5 |
1k<F≤1.5k | 450 + 0.12 | 500 + 0.12 | <0.5 | |||
3 mA | 10 nA | 45≤F≤1k | 270 + 0.6 | 300 + 0.6 | 50 | <0.5 |
1k<F≤1.5k | 360 + 0.6 | 400 + 0.6 | <0.5 | |||
30 mA | 100 nA | 45≤F≤1k | 270 + 6 | 300 + 6 | 50 | <0.5 |
1k<F≤1.5k | 360 + 6 | 400 + 6 | <0.5 | |||
300 mA | 1 μA | 45≤F≤1k | 270 + 60 | 300 + 60 | 15 | <0.5 |
1k<F≤1.5k | 360 + 60 | 400 + 60 | <0.5 | |||
1 A | 10μA | 45≤F≤1k | 270 + 200 | 300 + 200 | 15 | <0.5 |
1k<F≤1.5k | 360 + 200 | 400 + 200 | <0.5 | |||
5 A | 10μA | 45≤F≤1k | 270 + 600 | 300 + 600 | 4 | <0.5 |
1k<F≤1.5k | 360 + 600 | 400 + 600 | <0.5 | |||
20 A (30 A)[1] |
100μA | 45≤F≤1k | 270 + 4000 | 300 + 4000 | 2.5 | <0.5 |
1k<F≤1.5k | 360 + 4000 | 400 + 4000 | <0.5 | |||
Note [1]: 30 A range is optional. |
Range[1] | Resolution | Accuracy |
45.0000 Hz ≤ F ≤ 99.9999 Hz | 0.0001 Hz | ±0.01% |
100.000 Hz ≤ F ≤ 999.999 Hz | 0.001 Hz | ±0.01% |
1000.00 Hz ≤ F ≤ 1500.00 Hz | 0.01 Hz | ±0.01% |
Note [1]: The output mode is AC voltage or AC current. |
Frequency Range (f) | Voltage Range (U) | Current Range (I) | Optimum Accuracy %*power output [1][2] |
DC | 10 mV ~ 1100 V | 3μA ~ 22 A/33 A | ±0.05 |
45 Hz ~ 65 Hz | 3 V ~ 600 V | 0.3 mA ~ 22 A/33 A | ±0.1 |
Phase | Power Factor | Accuracy | ||
WATTS | VARS | λ=cosφ | Phase | Power Factor |
0° | 90° | 1.00000 | 0.05° | 0.000% |
10° | 80° | 0.98481 | 0.05° | 0.015% |
20° | 70° | 0.93969 | 0.05° | 0.032% |
30° | 60° | 0.86603 | 0.05° | 0.050% |
40° | 50° | 0.76604 | 0.05° | 0.073% |
50° | 40° | 0.64279 | 0.05° | 0.104% |
60° | 30° | 0.50000 | 0.05° | 0.151% |
70° | 30° | 0.34202 | 0.05° | 0.240% |
80° | 10° | 0.17365 | 0.05° | 0.495% |
90° | 0° | 0.00000 | - | - |
Note [1]: Phase range: 0.000 ° ~ 359.999 °, fineness: 0.005 ° Note [2]: Power factor range: -1 ~ 0 ~ 1, fineness: 0.000 1 |
Range [1] | Resolution | Accuracy | Shake |
1.000 00 Hz ≤ F ≤ 9.999 99 Hz | 10 μHz | ±(20 ppm*RD + 20 μHz) | <20 ns |
10.000 0 Hz ≤ F ≤ 99.999 9 Hz | 0.1 mHz | ||
100.000 Hz ≤ F ≤ 999.999 Hz | 1 mHz | ||
1.000 00 kHz ≤ F ≤ 9.999 99 kHz | 10 mHz | ||
10.000 0 kHz ≤ F ≤ 99.999 9 kHz | 0.1 Hz | ||
100.000 kHz ≤ F ≤ 999.999 kHz | 1 Hz | ||
1.000 00 MHz ≤ F ≤ 2.000 00 MHz |
|
||
Note [1]: The output type is TTL level. |
Type | Range | Measurement Range | Accuracy |
DCV | 1 V | ±(0 ~ 1.2) V | ±(0.006%*RD + 0.004%*RG) |
10 V | ±(0 ~ 12) V | ±(0.006%*RD + 0.004%*RG) | |
DCI | 2 mA | ±(0 ~ 2.4) mA | ±(0.006%*RD + 0.004%*RG) |
20 mA | ±(0 ~ 24) mA | ±(0.006%*RD + 0.004%*RG) |
Power supply | AC (220±22) V,(50±2) Hz |
Maximum power consumption | 600 VA |
Warm up time | Twice the time since last warmed up, to a maximum of 30 minutes. |
Temperature performance | Operating temperature:0°C~40°C Calibration temperature:18°C~28°C Storage temperature:-20°C~70°C |
Humidity performance | Operating humidity:<80% @ 30°C,<70% @ 40°C Storage humidity:(20%~80%) R·H,No condensation |
Communication interface | RS232 |
Dimensions | 450 mm(W)× 505 mm (D) × 203 mm (H), excluding handles and feets. |
Weight | About 19.5kg |