High-Precision TA2100 Wideband Power Calibrator for Accurate Measurements
Contact Supplier
Product Highlights
- High Precision Class 0.05: Delivers Class 0.05 power accuracy for reliable calibration results.
- Wide Voltage Output Range: Outputs AC/DC voltage from 0.3V to 1020V with high stability.
- High Current Capacity: Provides AC/DC current output up to 20.5A for versatile testing.
- Broad Frequency Range: Supports sine wave frequencies from 5Hz to 100kHz for wideband applications.
- Dual Voltage Output Mode: Features dual voltage output for complex calibration scenarios.
- 12-Month Warranty: Comes with a 12-month warranty and lifetime after-sales service.
- Multiple Protection Functions: Includes short-circuit, overload, and overheat protection for safety.
- Versatile Calibration Support: Suitable for calibrating power analyzers, voltmeters, and ammeters.
Product Attributes
- Customization
- Available
- After-sales Service
- Life Time
- Warranty
- 12 Months Excellent After-Sales Service
- Model NO.
- TA2100
- Power
- Electricity
- Voltage Output
- 0.3V~1020V
- Current Output
- 0.5mA~20.5A
- LCD Display
- With LCD Display
- Customized
- Non-Customized
- Standard Source of Auxiliary Voltage
- 2.5 mV ~ 5.5 V
- Frequency
- 5 Hz ~ 100 kHz
- Power Accuracy
- Class 0.05
- Transport Package
- Package for Exporting
- Trademark
- TUNKIA
- Origin
- China
- Production Capacity
- 1000
- Package Size
- 50.00cm * 66.00cm * 27.00cm
- Package Gross Weight
- 25.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of High-Precision TA2100 Wideband Power Calibrator for Accurate Measurements
Find Similar Products
Product Description
1. Summary
TA2100 Is a wide range, high precision, high stability broadband power calibrator, the instrument can output DC voltage, current and power, and has a dual voltage output mode, suitable for calibration power analyzer, AC / DC power meter, voltmeter, ammeter and other electrical measuring instruments.2. Product features
- Standard Source of AC / DC Voltage: 0.3 V ~ 1020 V
- Standard Source of AC / DC Current: 0.5 mA ~ 20.5 A
- Standard Source of Auxiliary Voltage: 2.5 mV ~ 5.5 V
- Sine Wave Frequency: 5 Hz ~ 100 kHz
- Power Accuracy: Class 0.05
- Phase-Shifted Output
- Wideband Power Output
- A variety of quantity and value output mode
- Cross-guide amplifier (optional)
3. Main applications
| ☆ Calibration power analyzer (medium to low precision) |
![]() |
|
| ☆ Calibration power analyzer (medium to high precision) |
![]() |
|
4. Main technical specifications
4.1 AC / DC Voltage Output
| Range | Resolving Power | Voltage Output Range | Output Frequency Range | Maximum Load Current |
| 3 V | 10 μV | 0.30000 V ~ 3.30000 V | DC, 5 Hz ~ 100 kHz | 50 mA |
| 10 V | 100 μV | 1.0000 V ~ 11.0000 V | DC, 5 Hz ~ 100 kHz | 50 mA |
| 30 V | 100 μV | 3.0000 V ~ 33.0000 V | DC, 5 Hz ~ 100 kHz | 50 mA |
| 100 V | 1 mV | 10.000 V ~ 110.000 V | DC, 45 Hz ~ 100 kHz | 50 mA |
| 300 V | 1 mV | 30.000 V ~ 330.000 V | DC, 45 Hz ~ 100 kHz | 50 mA |
| 600 V | 1 mV | 60.000 V ~ 660.000 V | DC, 45 Hz ~ 100 kHz | 20 mA |
| 1000 V | 10 mV | 100.00 V ~ 1020.00 V | DC, 45 Hz ~ 10 kHz | 20 mA |
| Range | Measurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (ppm * reading + ppm * range) | ||||||
| DC | 5~45 | 45~1k | 1k~10k | 10k~20k | 20k~50k | 50k~100k | |
| 3 V | 120+80 | 300+200 | 120+80 | 300+200 | 500+300 | 600+400 | 1000+500 |
| 10 V | 120+80 | 300+200 | 120+80 | 300+200 | 500+300 | 600+400 | 1000+500 |
| 30 V | 120+80 | 300+200 | 120+80 | 300+200 | 500+300 | 600+400 | 1000+500 |
| 100 V | 120+80 | - | 120+80 | 300+200 | 500+300 | 600+400 | 1000+500 |
| 300 V | 120+80 | - | 120+80 | 300+200 | 500+300 | 600+400 | 1000+500 |
| 600 V | 120+80 | - | 120+80 | 300+200 | 500+300 | 600+400 | 1000+500 |
| 1000 V | 120+80 | - | 120+80 | 300+200 | - | - | - |
- Range switching: manual or automatic shift
- Protection function: short-circuit protection, overload protection, overheat protection
4.2 AC / DC Current Output
| Range | Resolving Power | Current Output Range | Output Frequency Range | Maximum Load Voltage |
| 5 mA | 10 nA | 0.50000 mA ~ 5.50000 mA | DC, 5 Hz ~ 100 kHz | 7 V |
| 10 mA | 100 nA | 1.0000 mA ~ 11.0000 mA | DC, 5 Hz ~ 100 kHz | 7 V |
| 25 mA | 100 nA | 2.5000 mA ~ 27.5000 mA | DC, 5 Hz ~ 100 kHz | 7 V |
| 50 mA | 100 nA | 5.0000 mA ~ 55.0000 mA | DC, 5 Hz ~ 100 kHz | 7 V |
| 100 mA | 1 μA | 10.000 mA ~ 110.000 mA | DC, 5 Hz ~ 100 kHz | 7 V |
| 200 mA | 1 μA | 20.000 mA ~ 220.000 mA | DC, 5 Hz ~ 100 kHz | 6 V |
| 500 mA | 1 μA | 50.000 mA ~ 550.000 mA | DC, 5 Hz ~ 100 kHz | 6 V |
| 1 A | 10 μA | 0.10000 A ~ 1.10000 A | DC, 5 Hz ~ 100 kHz | 6 V |
| 2.5 A | 10 μA | 0.25000 A ~ 2.75000 A | DC, 5 Hz ~ 100 kHz | 6 V |
| 5 A | 10 μA | 0.50000 A ~ 11.0000 A | DC, 5 Hz ~ 100 kHz | 6 V |
| 10 A | 100 μA | 1.0000 A ~ 11.0000 A | DC, 5 Hz ~ 100 kHz | 6 V |
| 20 A | 100 μA | 2.0000 A ~ 20.5000 A | DC, 5 Hz ~ 100 kHz | 6 V |
| Range | Measurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (ppm * reading + ppm * range) | ||||||
| DC | 5~45 | 45~1k | 1k~10k | 10k~20k | 20k~50k | 50k~100k | |
| 5 mA | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 10 mA | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 25 mA | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 50 mA | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 100 mA | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 200 mA | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 500 mA | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 1 A | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 2.5 A | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 5 A | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 10 A | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
| 20 A | 120+80 | 300+200 | 120+80 | 300+200 | 600+400 | 1000+500 | 2k + 1k |
- Range switch: manual or automatic shift; open circuit protection, overload protection, overheating protection
4.3 Auxiliary Voltage Output
| Range | Resolving Power | Voltage Output Range | Output Frequency Range | Maximum Load Current |
| 25 mV | 100 nV | 2.5000 mV ~ 27.5000 mV | DC, 5 Hz ~ 100 kHz | 10 mA |
| 50 mV | 100 nV | 5.0000 mV ~ 55.0000 mV | DC, 5 Hz ~ 100 kHz | 10 mA |
| 100 mV | 1 μV | 10.000 mV ~ 110.000 mV | DC, 5 Hz ~ 100 kHz | 10 mA |
| 250 mV | 1 μV | 25.000 mV ~ 275.000 mV | DC, 5 Hz ~ 100 kHz | 10 mA |
| 500 mV | 1 μV | 50.000 mV ~ 550.000 mV | DC, 5 Hz ~ 100 kHz | 10 mA |
| 1 V | 10 μV | 0.10000 V ~ 1.10000 V | DC, 5 Hz ~ 100 kHz | 10 mA |
| 2.5 V | 10 μV | 0.25000 V ~ 2.75000 V | DC, 5 Hz ~ 100 kHz | 10 mA |
| 5 V | 10 μV | 0.50000 V ~ 5.50000 V | DC, 5 Hz ~ 100 kHz | 10 mA |
| Range | Measurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (ppm * reading + ppm * range) | ||||||
| DC | 5~45 | 45~1k | 1k~10k | 10k~20k | 20k~50k | 50k~100k | |
| 25 mV | 150+200 | 350+250 | 150+200 | 350+250 | 600+400 | 1000+500 | 1200+800 |
| 50 mV | 150+200 | 350+250 | 150+200 | 350+250 | 600+400 | 1000+500 | 1200+800 |
| 100 mV | 150+200 | 350+250 | 150+200 | 350+250 | 600+400 | 1000+500 | 1200+800 |
| 250 mV | 150+200 | 350+250 | 150+200 | 350+250 | 600+400 | 1000+500 | 1200+800 |
| 500 mV | 120+80 | 300+200 | 120+80 | 300+200 | 500+300 | 600+400 | 1000+500 |
| 1 V | 120+80 | 300+200 | 120+80 | 300+200 | 500+300 | 600+400 | 1000+500 |
| 2.5 V | 120+80 | 300+200 | 120+80 | 300+200 | 500+300 | 600+400 | 1000+500 |
| 5 V | 120+80 | 300+200 | 120+80 | 300+200 | 500+300 | 600+400 | 1000+500 |
- Range switching: manual or automatic shift
- Wiring mode: BNC plug
- Protection function: short-circuit protection, overload protection, overheat protection
- Note: This output is especially suitable for the sensor small signal input of the power analyzer
4.4 Frequency
| Adjustable range | Resolving Power | Annual Measurement Uncertainty (k=2) @ (23°C ± 5°C) |
| 5.000 0 Hz ≤ F ≤ 99.999 9 Hz | 0.000 1 Hz | 0.01% |
| 100.000 Hz ≤ F ≤ 999.999 Hz | 0.001 Hz | 0.01% |
| 1.000 00 kHz ≤ F ≤ 9.999 99 kHz | 0.01 Hz | 0.01% |
| 10.000 0 kHz ≤ F ≤ 99.999 9 kHz | 0.1 Hz | 0.01% |
| 100.000 kHz | 1 Hz | 0.01% |
4.5 Phase
| Phase Position[1][2] | Annual Measurement Uncertainty (k=2) @ (23°C ± 5°C) | ||||||
| 5~45Hz | 45~1kHz | 1k~10kHz | 10k~20kHz | 20k~50kHz | 50k~100kHz | ||
| φU -I | 0.05° | 0.02° | 0.05° | 0.1° | 0.2° | 0.5° | |
| φU -AUX | 0.05° | 0.02° | 0.05° | 0.1° | 0.2° | 0.5° | |
| Note [1]: Adjustment range: 0.000° ~ 359.999° Note [2]: Resolution: 0.001° |
|||||||
| Phase Position (φ ) |
Power Factor (λ ) |
The Active Power Uncertainty Component caused by the Phase Uncertainty[3] | |||||
| 5~45Hz | 45~1kHz | 1k~10kHz | 10k~20kHz | 20k~50kHz | 50k~100kHz | ||
| 0° | 1.00000 | 0.000% | 0.000% | 0.000% | 0.000% | 0.001% | 0.004% |
| 10° | 0.98481 | 0.015% | 0.006% | 0.015% | 0.031% | 0.062% | 0.158% |
| 20° | 0.93969 | 0.032% | 0.013% | 0.032% | 0.064% | 0.128% | 0.321% |
| 30° | 0.86603 | 0.050% | 0.020% | 0.050% | 0.101% | 0.202% | 0.508% |
| 40° | 0.76604 | 0.073% | 0.029% | 0.073% | 0.147% | 0.294% | 0.736% |
| 50° | 0.64279 | 0.104% | 0.042% | 0.104% | 0.208% | 0.417% | 1.044% |
| 60° | 0.50000 | 0.151% | 0.060% | 0.151% | 0.302% | 0.605% | 1.515% |
| 70° | 0.34202 | 0.240% | 0.096% | 0.240% | 0.480% | 0.960% | 2.401% |
| 80° | 0.17365 | 0.495% | 0.198% | 0.495% | 0.990% | 1.980% | 4.953% |
| 90° | 0.00000 | - | - | - | - | - | - |
Note [3]: Calculation formula:![]() |
|||||||
4.6 AC / DC Power Output
| Quantity Range Combination | Measurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (% * power output)[1] | ||||||
| DC | 5~45 | 45~1k | 1k~10k | 10k~20k | 20k~50k | 50k~100k | |
| Voltage and Current Output (U & I) @ (λ =1) | |||||||
| (3 V … 30 V) & (5 mA … 20 A) |
0.03 | 0.07 | 0.03 | 0.07 | 0.13 | 0.18 | 0.34 |
| (100 V … 600 V) & (5 mA … 20 A) |
0.03 | - | 0.03 | 0.07 | 0.13 | 0.18 | 0.34 |
| 1000 V & (5 mA … 20 A) |
0.03 | - | 0.03 | 0.07 | - | - | - |
| Dual Voltage Output (U & AUX) @ (λ =1) | |||||||
| (3 V … 30 V) & (25 mV … 250 mV) |
0.04 | 0.08 | 0.04 | 0.08 | 0.13 | 0.18 | 0.25 |
| (3 V … 30 V) & (500 mV … 5 V) |
0.03 | 0.07 | 0.03 | 0.07 | 0.13 | 0.18 | 0.25 |
| (100 V … 600 V) & (25 mV … 250 mV) |
0.04 | - | 0.04 | 0.08 | 0.13 | 0.18 | 0.25 |
| (100 V … 600 V) & (500 mV … 5 V) |
0.03 | - | 0.03 | 0.07 | 0.13 | 0.18 | 0.25 |
| 1000 V & (25 mV … 250 mV) |
0.04 | - | 0.04 | 0.08 | - | - | - |
| 1000 V & (500 mV … 5 V) |
0.03 | - | 0.03 | 0.07 | - | - | - |
| Note [1]: AC / DC power output range (virtual load): 0.15 mW ~ 20.91 kW Note [2]: Power factor adjustment range: -1 ~ 0 ~ + 1, resolution: 0.000 01 Note [3]: Power uncertainty calculation formula under other power factors: voltage and current output mode, dual voltage output mode, which: the voltage measurement uncertainty, the current measurement uncertainty, the auxiliary voltage measurement uncertainty, and the measurement uncertainty caused by the power factor. |
|||||||
5. General Technical Specifications
| Power Supply Voltage | AC (220±22) V ,(50±2) Hz |
| Preheating Time | 2 times from the last preheating time, up to 30 minutes. |
| Temperature Performance | Operating temperature: 0°C~40°C Calibration temperature: 18°C~28°C Storage temperature: -20°C~70°C |
| Humidity Performance | Working Humidity: <80% @ 30°C, <70% @ 40°C Storage humidity: (20%~80%) R · H, no condensation |
| Above Sea Class | <3000 m |
| Communication Interface | RS232×1,USB×1,LAN×1 |
About the Supplier
This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI2191183". Items marked "" are certified.
Company Profile
TUNKIA Co., Ltd. is a unique company with top R& D strength in electromagnetics in China. Since its founding in 1998, Changed its name to TUNKIA in 2006. TUNKIA focus on electromagnetic measurement technology, gathered more than 360 personnel all over the world.
At present, Tunkia has launched 32 categories and over 500 advanced electromagnetic measurement equipment, serving over 10, 000 users, and exported to over 20 countries in the world.
Electrical measurement with current from PA to 10kA, voltage from nV to 100kV, resistance from nΩ To TΩ , frequency from DC to 10MHz and accuracy from 10-4 to 10-6. It all have been converted into 22 series electrical testing equipment: Measurement standards, AC & DC instruments, new energy detection, etc.
For magnetic measurement, Tunkia has researched 11 series testing equipment for material and products. We provide comprehensive testing solutions about magnetic intensity, flux, permeability, hysteresis loop, etc.
Tunkia have been highly recognized by the Chinese government and international organizations. Since 2014, we have took part in IEC meetings on behalf of China, participated in the formulation and revision of more than 40 national standards.
Tunkia is striving to become a world-class supplier of electromagnetic measurement equipment.
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory
- Address
- No. 16 Panpan Road, Changsha, Hunan, China
-
Plant Area
- 8000 square meters
-
Number of Employees
- 363
-
Registered Capital
- 25,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR, EXW
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: one month -
Nearest Port
- Changsha Port
Our Production Capability & Technical Expertise
-
Main Products
- Magnetic Measurement, Electrical Measurement, Gaussmeter, Multifunction Calibrator
-
Production Machines
- SMT Machine, Printing Machine, Assembly & Debugging Line, Automatic Online Function Test (EPS&SST)
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 120 people
-
Own Brand
- Yes
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2006-06-16
- Export Year
- 2021-10-11
-
Main Markets
- Europe, Southeast Asia/ Mideast, East Asia(Japan/ South Korea), Domestic
-
Number of Foreign Trading Staff
- 2
-
Overseas Agent/Branch
- No
FAQ
- What is the power accuracy of the TA2100?
- The TA2100 offers Class 0.05 power accuracy, making it suitable for calibrating medium to low precision power analyzers.
- What is the output voltage range?
- The standard source of AC/DC voltage ranges from 0.3V to 1020V.
- What is the maximum current output?
- The device can output AC/DC current from 0.5mA to 20.5A.
- What is the frequency range supported?
- The sine wave frequency range is 5Hz to 100kHz.
- Does the TA2100 support dual voltage output?
- Yes, the instrument features a dual voltage output mode for enhanced calibration capabilities.
- What is the warranty period?
- The product comes with a 12-month warranty and lifetime after-sales service.
- Is the TA2100 customizable?
- No, the TA2100 is specified as Non-Customized.
- What protection functions are included?
- The device includes short-circuit protection, overload protection, and overheat protection.
Send your message to this supplier
People who viewed this also viewed
-
US$1,000.00-10,000.00 / Piece
-
US$1,000.00-10,000.00 / Piece
-
US$1,000.00-10,000.00 / Piece
-
US$1,000.00-10,000.00 / Piece
-
US$700.00-1,000.00 / Set
-
US$1,000.00-10,000.00 / Set
-
US$1,000.00-1,500.00 / Piece
-
US$1,000.00-1,500.00 / Piece
-
US$30,000.00-35,000.00 / Set
-
US$1,000.00-10,000.00 / Piece
Product Groups
- Multi-function Calibrators Series
- EV Charger Tester
- Electrical Reference Standards
- Resistance Standards Series
- DC Power Energy Standards
- Wideband Power Source/Meter
- AC/DC Current Source/Meter
- Single/Three Phase Energy Meter Calibration
- Single/Three Phase Standard Meter
- High Voltage Standard Instrument
- Industrial Instrument Testing
- Safety Instrument Detection
Find Similar Products By Category
- Supplier Homepage
- Products
- Wideband Power Source/Meter
- High-Precision TA2100 Wideband Power Calibrator for Accurate Measurements
Related Categories
Hot Searches
- Standard Meter Factories
- Power Instrument Factories
- Meter Energy Factories
- Power Energy Meter Factories
- Meter Calibrator
- Calibrator Instrument
- Power Calibrator
- Electric Meter Calibrator
- Current Calibrator
- single phase power calibrator Bulkbuy