Tunkia TD1250 Earth Continuity Testers Calibration Device for Earth Continuty Resistance Tester
Contact Supplier
Product Highlights
- High Precision Calibration: Accuracy classes 0.02, 0.05, and 0.1 for reliable earth continuity tester calibration.
- Advanced Current Measurement: Measures AC/DC current from 0.5 A to 60 A with optional high-range configurations.
- Harmonic & Ripple Analysis: Supports 2nd-32nd harmonic measurement and DC ripple test with up to 1 kHz bandwidth.
- Four-Terminal Connection: Eliminates lead resistance errors for precise low-resistance measurements.
- LCD Touch Screen Interface: Intuitive operation with real-time waveform display and data statistics functions.
- Comprehensive Data Statistics: Records Max, Min, Avg, Span, Stab, and deviation for detailed test analysis.
- Lifetime After-Sales Service: Provides lifetime technical support and service for the TD1250 calibration device.
Product Attributes
- Customization
- Available
- After-sales Service
- Life Time
- Warranty
- 12 Months Excellent for Service
- Model NO.
- TD1250
- Power
- Electricity
- Voltage Output
- 264V
- Current Output
- 120A
- LCD Display
- With LCD Display
- Customized
- Non-Customized
- Transport Package
- Package for Exporting
- Trademark
- TUNKIA
- Origin
- China
- Production Capacity
- 1000
Product Images of Tunkia TD1250 Earth Continuity Testers Calibration Device for Earth Continuty Resistance Tester
Find Similar Products
Product Description
1. Summary
TD1250 is a precision AC/DC artificial resistance, intergraded a AC/DC ammeter. Applied for calibrating earth continuity tester and other AC/DC low resistance instruments. It can calibrate max permissible error, alarm setting error, test current setting error etc.2. Features
- DC resistance simulation:200 μΩ (100 μΩ optional)~20 Ω.
- AC resistance simulation:500 μΩ (300 μΩ optional)~15 Ω.
- AC/DC current measurement:0.5 A~36 A(60A option).
- Accuracy class:0.02/ 0.05/ 0.1.
- Harmonic and ripple function.
- Current waveform display function.
- With data statistics and analysis, stability test function.
- LCD touch screen.
- Setting output values by keys.
3. Applications
4. Characteristics
| ☆ Resistance Output |
![]() |
|
| ☆ Multiple Output Mode |
![]() |
|
![]() |
|
| ☆ Multiple Output Mode |
![]() |
|
☆ AC+DC Measurement |
![]() |
|
| ☆ DC Characteristic Analysis | |
![]() |
|
| Serial Number | Explanation |
| Current overshoot : The maximum value of the test current is displayed in DC mode, which is used to calculate the operating current overshoot; | |
| Waveform display:With oscilloscope function ,can real time display of measured current waveform. | |
| Ripple measurement:the instrument directly displays the ripple measurement results on the screen for users to read. | |
| ☆ AC Characteristic Analysis | |
![]() |
|
| Serial Number | Explanation |
| Harmonic distortion:Display THD/T(harmonic vs. full wave),THD/F(harmonic vs. fundamental). Easy for users to real intuitively. | |
| Harmonic data:Display the amplitude (RMS), content(%), phase of the 2nd~32nd harmonic, facilitate user analysis. | |
| DC component:Display the DC component in the AC current signal. Easy for users to real intuitively. | |
| Waveform display:with waveform display function, real time display of measured current waveform. | |
| ☆ Statistical Analysis | |
![]() |
|
| Serial Number | Function Description |
| Scoring cycle:0.5 s ~ 20 s integration period can be set(1s by default); it is convenient for users to set sampling data according to actual needs. | |
| Statistical analysis:Real time record and statistics of current test data, including Max, Min, Avg, Span, Stab, S.dev, Time, test times N,etc; Easy for users to real intuitively. | |
5. Specifications
5.1 DC Current Measurement
| Range | Resolution | Accuracy ±(ppm of reading + ppm of range) [1] |
|||
| Class 0.1 | Class 0.05 | Class 0.02 | |||
| 1 A | 10 μA | 0.05 + 1.5 | 0.02 + 1.0 | 0.01 + 0.5 | |
| 2 A | 10 μA | 0.05 + 1.5 | 0.02 + 1.0 | 0.01 + 0.5 | |
| 5 A | 10 μA | 0.05 + 1.5 | 0.02 + 1.0 | 0.01 + 0.5 | |
| 10 A | 100 μA | 0.05 + 1.5 | 0.02 + 1.0 | 0.01 + 0.5 | |
| 20 A | 100 μA | 0.05 + 2.5 | 0.02 + 2.0 | 0.01 + 1.0 | |
| 30 A | 100 μA | 0.05 + 5.0 | 0.02 + 3.0 | 0.01 + 2.0 | |
| 50 A [2] | 100 μA | 0.05 + 5.0 | 0.02 + 3.0 | 0.01 + 2.0 | |
| Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%). Note [2]: 50 A Range is optional Accessories | |||||
- Measuring range(TD1250-30A specification, max range:30 A):0.5 A~36 A.
- Measuring range(TD1250-50A specification, max range: 50 A):0.5 A~60 A.
- Ripple frequency bandwidth: 1 Hz ~ 1 kHz, accuracy: ±0.02%*RG,effective value.
5.2 AC Current Measurement
| Range | Resolution | Accuracy ±(ppm of reading + ppm of range) [1] |
|||
| Class 0.1 | Class 0.05 | Class 0.02 | |||
| 1 A | 10 μA | 0.10 + 3.0 | 0.05 + 2.0 | 0.02 + 1.0 | |
| 2 A | 10 μA | 0.10 + 3.0 | 0.05 + 2.0 | 0.02 + 1.0 | |
| 5 A | 10 μA | 0.10 + 3.0 | 0.05 + 2.0 | 0.02 + 1.0 | |
| 10 A | 100 μA | 0.10 + 3.0 | 0.05 + 2.0 | 0.02 + 1.0 | |
| 20 A | 100 μA | 0.10 + 5.0 | 0.05 + 3.0 | 0.02 + 2.0 | |
| 30 A | 100 μA | 0.10 + 10 | 0.05 + 5.0 | 0.02 + 5.0 | |
| 50 A[2] | 100 μA | 0.10 + 10 | 0.05 + 5.0 | 0.02 + 5.0 | |
- Measuring range(TD1250-30A specification, max range:30 A):0.5 A~36 A.
- Measuring range(TD1250-50A specification, max range: 50 A):0.5 A~60 A.
- AC frequency: 45 Hz ~ 65 Hz, accuracy: ±0.01 Hz, harmonic measurement: 2nd~32nd.
5.3 DC Simulated Resistance
| Current Range | Setting Range of Resistance Value R | Adjustment Fineness | Accuracy ±(A%*reading+R0) |
||
| Class 0.1 | Class 0.05 | Class 0.02 | |||
| 50 A [2] | 100 μΩ ≤ R ≤ 4 mΩ | 20 nΩ | 0.1 + 3 μΩ | 0.08 + 1.5 μΩ | 0.04 + 0.8 μΩ |
| 4 mΩ < R ≤ 40 mΩ | 200 nΩ | 0.1 + 3 μΩ | 0.06 + 1.5 μΩ | 0.03 + 0.8 μΩ | |
| 40 mΩ < R ≤ 400 mΩ | 2 μΩ | 0.1 | 0.05 | 0.02 | |
| 30A | 200 μΩ ≤ R ≤ 6 mΩ | 30 nΩ | 0.1 + 5 μΩ | 0.08 + 3 μΩ | 0.04 + 1.5 μΩ |
| 6 mΩ < R ≤ 60 mΩ | 300 nΩ | 0.1 + 5 μΩ | 0.06 + 3 μΩ | 0.03 + 1.5 μΩ | |
| 60 mΩ < R ≤ 600 mΩ | 3 μΩ | 0.1 | 0.05 | 0.02 | |
| 20A | 400 μΩ ≤ R ≤ 10 mΩ | 100 nΩ | 0.1 + 6 μΩ | 0.08 + 5 μΩ | 0.04 + 2.5 μΩ |
| 10 mΩ < R ≤ 100 mΩ | 1 μΩ | 0.1 + 6 μΩ | 0.06 + 5 μΩ | 0.03 + 2.5 μΩ | |
| 100 mΩ ≤ R ≤ 1 Ω | 10 μΩ | 0.1 | 0.05 | 0.02 | |
| 10A | 800 μΩ ≤ R ≤ 20 mΩ | 100 nΩ | 0.1 + 15 μΩ | 0.08 + 6 μΩ | 0.04 + 3 μΩ |
| 20 mΩ < R ≤ 200 mΩ | 1 μΩ | 0.1 + 15 μΩ | 0.06 + 6 μΩ | 0.03 + 3 μΩ | |
| 200 mΩ < R ≤ 2 Ω | 10 μΩ | 0.1 | 0.05 | 0.02 | |
| 5A | 1.6 mΩ ≤ R ≤ 40 mΩ | 200 nΩ | 0.15 + 30 μΩ | 0.09 + 15 μΩ | 0.045 + 6 μΩ |
| 40 mΩ < R ≤ 400 mΩ | 2 μΩ | 0.12 + 30 μΩ | 0.07 + 15 μΩ | 0.035 + 6 μΩ | |
| 400 mΩ < R ≤ 4 Ω | 20 μΩ | 0.1 | 0.05 | 0.025 | |
| 2A | 4 mΩ ≤ R ≤ 100 mΩ | 1 μΩ | 0.20 + 50 μΩ | 0.10 + 30 μΩ | 0.055 + 15 μΩ |
| 100 mΩ < R ≤ 1 Ω | 10 μΩ | 0.20 + 50 μΩ | 0.10 + 30 μΩ | 0.045 + 15 μΩ | |
| 1 Ω < R ≤ 10 Ω | 100 μΩ | 0.1 | 0.05 | 0.035 | |
| 1A | 8 mΩ ≤ R ≤ 200 mΩ | 1 μΩ | 0.30 + 90 μΩ | 0.15 + 50 μΩ | 0.08 + 30 μΩ |
| 200 mΩ < R ≤ 2 Ω | 10 μΩ | 0.30 + 90 μΩ | 0.15 + 50 μΩ | 0.07 + 30 μΩ | |
| 2 Ω < R ≤ 20 Ω | 100 μΩ | 0.2 | 0.1 | 0.06 | |
| Note [2]: 50 A Range is optional Accessories | |||||
- Simulated resistance range(TD1250-30A specification, maximum range: 30 A):200 μΩ~20 Ω
- Display Digits:6-digit decimal display, set the resistance value through the number keys.
5.4 AC Simulated Resistance
| Current Range | Setting Range of Resistance Value R | Adjustment Fineness | Accuracy ±(A%*reading+R0) |
||
| Class 0.1 | Class 0.05 | Class 0.02 | |||
| 50 A [2] | 300 μΩ ≤ R ≤ 3 mΩ | 20 nΩ | 0.3 + 5 μΩ | 0.15 + 3 μΩ | 0.08 + 1.5 μΩ |
| 3 mΩ < R ≤ 30 mΩ | 200 nΩ | 0.24 + 5 μΩ | 0.12 + 3 μΩ | 0.06 + 1.5 μΩ | |
| 30 mΩ < R ≤ 300 mΩ | 2 μΩ | 0.2 | 0.1 | 0.04 | |
| 30A | 500 μΩ ≤ R ≤ 5 mΩ | 30 nΩ | 0.3 + 8 μΩ | 0.15 + 5 μΩ | 0.08 + 2.5 μΩ |
| 5 mΩ < R ≤ 50 mΩ | 300 nΩ | 0.24 + 8 μΩ | 0.12 + 5 μΩ | 0.06 + 2.5 μΩ | |
| 50 mΩ < R ≤ 500 mΩ | 3 μΩ | 0.2 | 0.1 | 0.04 | |
| 20A | 750 μΩ ≤ R ≤ 7.5 mΩ | 50 nΩ | 0.3 + 10 μΩ | 0.15 + 6 μΩ | 0.08 + 4 μΩ |
| 7.5 mΩ < R ≤ 75 mΩ | 500 nΩ | 0.24 + 10 μΩ | 0.12 + 6 μΩ | 0.06 + 4 μΩ | |
| 75 mΩ ≤ R ≤ 750 mΩ | 5 μΩ | 0.2 | 0.10 | 0.04 | |
| 10A | 1.5 mΩ < R ≤ 15 mΩ | 100 nΩ | 0.3 + 20 μΩ | 0.15 + 12 μΩ | 0.08 + 8 μΩ |
| 15 mΩ < R ≤ 150 mΩ | 1 μΩ | 0.24 + 20 μΩ | 0.12 + 12 μΩ | 0.06 + 8 μΩ | |
| 150 mΩ < R ≤ 1.5 Ω | 10 μΩ | 0.2 | 0.1 | 0.04 | |
| 5A | 3 mΩ ≤ R ≤ 30 mΩ | 200 nΩ | 0.3 + 20 μΩ | 0.2 + 15 μΩ | 0.1 + 12 μΩ |
| 30 mΩ < R ≤ 300 mΩ | 2 μΩ | 0.3 + 20 μΩ | 0.15 + 15 μΩ | 0.07 + 12 μΩ | |
| 300 mΩ < R ≤ 3 Ω | 20 μΩ | 0.2 | 0.1 | 0.05 | |
| 2A | 7.5 mΩ ≤ R ≤ 75 mΩ | 5 μΩ | 0.4 + 80 μΩ | 0.2 + 50 μΩ | 0.11 + 30 μΩ |
| 75 mΩ < R ≤ 750 mΩ | 50 μΩ | 0.4 + 80 μΩ | 0.2 + 50 μΩ | 0.09 + 30 μΩ | |
| 750 mΩ < R ≤ 7.5 Ω | 500 μΩ | 0.2 | 0.14 | 0.07 | |
| 1A | 15 mΩ ≤ R ≤ 150 mΩ | 1 μΩ | 0.6 + 150 μΩ | 0.3 + 90 μΩ | 0.16 + 60 μΩ |
| 150 mΩ < R ≤ 1.5 Ω | 10 μΩ | 0.6 + 150 μΩ | 0.3 + 90 μΩ | 0.14 + 60 μΩ | |
| 1.5 Ω < R ≤ 15 Ω | 100 μΩ | 0.4 | 0.2 | 0.12 | |
| Note [2]: 50 A Range is optional Accessories | |||||
- Simulated resistance range(TD1250-30A specification, maximum range: 30 A):500 μΩ~15 Ω.
- Display Digits:6-digit decimal display, set the resistance value through the number keys.
- AC frequency: 45 Hz ~ 65 Hz, accuracy: ±0.01 Hz.
6. General Specifications
| Power Supply | AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz |
| Temperature Performance | Working temperature:0°C~45°C; Storage temperature:-20°C~70°C |
| Humidity Performance | Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C Storage humidity:(20%~80%) R·H,non-condensing |
| Interface | RS232 |
7. Ordering Information
About the Supplier
This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI2191183". Items marked "" are certified.
Company Profile
TUNKIA Co., Ltd. is a unique company with top R& D strength in electromagnetics in China. Since its founding in 1998, Changed its name to TUNKIA in 2006. TUNKIA focus on electromagnetic measurement technology, gathered more than 360 personnel all over the world.
At present, Tunkia has launched 32 categories and over 500 advanced electromagnetic measurement equipment, serving over 10, 000 users, and exported to over 20 countries in the world.
Electrical measurement with current from PA to 10kA, voltage from nV to 100kV, resistance from nΩ To TΩ , frequency from DC to 10MHz and accuracy from 10-4 to 10-6. It all have been converted into 22 series electrical testing equipment: Measurement standards, AC & DC instruments, new energy detection, etc.
For magnetic measurement, Tunkia has researched 11 series testing equipment for material and products. We provide comprehensive testing solutions about magnetic intensity, flux, permeability, hysteresis loop, etc.
Tunkia have been highly recognized by the Chinese government and international organizations. Since 2014, we have took part in IEC meetings on behalf of China, participated in the formulation and revision of more than 40 national standards.
Tunkia is striving to become a world-class supplier of electromagnetic measurement equipment.
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory
- Address
- No. 16 Panpan Road, Changsha, Hunan, China
-
Plant Area
- 8000 square meters
-
Number of Employees
- 363
-
Registered Capital
- 25,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR, EXW
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: one month -
Nearest Port
- Changsha Port
Our Production Capability & Technical Expertise
-
Main Products
- Magnetic Measurement, Electrical Measurement, Gaussmeter, Multifunction Calibrator
-
Production Machines
- SMT Machine, Printing Machine, Assembly & Debugging Line, Automatic Online Function Test (EPS&SST)
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 120 people
-
Own Brand
- Yes
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2006-06-16
- Export Year
- 2021-10-11
-
Main Markets
- Europe, Southeast Asia/ Mideast, East Asia(Japan/ South Korea), Domestic
-
Number of Foreign Trading Staff
- 2
-
Overseas Agent/Branch
- No
FAQ
- What is the warranty period for the TD1250?
- The device comes with a 12-month warranty and lifetime after-sales service.
- What accuracy classes are available?
- The TD1250 offers accuracy classes of 0.02, 0.05, and 0.1.
- Can the device measure harmonics?
- Yes, it supports 2nd to 32nd harmonic measurement and displays THD/T and THD/F.
- What is the maximum current output?
- The standard range is up to 36 A, with an optional 50 A range reaching up to 60 A.
- Does it support AC and DC measurements?
- Yes, it supports both AC (45-65 Hz) and DC measurement modes with ripple analysis.
- How is the resistance value set?
- Users can set output values via physical keys or the LCD touch screen.
- Is the device customizable?
- No, the product is listed as Non-Customized.
Send your message to this supplier
People who viewed this also viewed
-
US$1,000.00-10,000.00 / Piece
-
US$1,000.00-10,000.00 / Piece
-
US$1,000.00-10,000.00 / Piece
-
US$1,000.00-10,000.00 / Piece
-
US$700.00-1,000.00 / Set
-
US$1,000.00-10,000.00 / Set
-
US$1,000.00-1,500.00 / Piece
-
US$1,000.00-1,500.00 / Piece
-
US$30,000.00-35,000.00 / Set
-
US$1,000.00-10,000.00 / Piece
Product Groups
- Multi-function Calibrators Series
- EV Charger Tester
- Electrical Reference Standards
- Resistance Standards Series
- DC Power Energy Standards
- Wideband Power Source/Meter
- AC/DC Current Source/Meter
- Single/Three Phase Energy Meter Calibration
- Single/Three Phase Standard Meter
- High Voltage Standard Instrument
- Industrial Instrument Testing
- Safety Instrument Detection
Find Similar Products By Category
- Supplier Homepage
- Products
- Safety Instrument Detection
- Tunkia TD1250 Earth Continuity Testers Calibration Device for Earth Continuty Resistance Tester
Related Categories
Hot Searches
- Testing Device Factories
- Battery Tester Factories
- China Tester Factories
- System Tester Factories
- 1 Testers
- Color Testers
- Top Testers
- Digital Voltage Testers
- Installation Testers
- earth continuity testers verification device Bulkbuy