TK6700 Electric Welding Machine Electric Power Parameters Comprehensive Calibrator
1. Summary
TK6700 is a AC and DC welding machine power parameter comprehensive calibrator with built-in high-current precision measurement module and resistance load. It can be used to calibrate the current or voltage of the welding machine without disassembling it. he maximum measurement current can reach 1 kA, and the accuracy can be selected in two specifications: Class 0.05 and Class 0.1.
2. Features
- AC and DC voltage measurement: 0.1 V~180 V (optional 500 V).
- AC and DC current measurement: 10 A~1 kA.
- Optional specifications: class 0.05 and class 0.1.
- AC measurement frequency: 40 Hz~1 kHz.
- Support 2nd~18th harmonic measurement.
- Supports exporting data via USB.
3. Applications
☆ Calibrate the AC and DC welding machine power supply |
|
- The AC and DC voltage measurement range is 0 1 V~180 V (optional 500 V), and the AC and DC current measurement range is: 10 A~1 kA;
- Best accuracy class 0.05, suitable for calibration class 0.2 and below AC and DC arc welding power supply or other high-current output equipment.
|
4. Characteristics
☆ On-site portable design |
|
- The device adopts imported protective box, which is suitable for carrying to the site for work.
- The 600 A load tank is equipped with tie rods and rollers, which facilitate the rapid hauling of the entire equipment.
|
☆ USB data export |
|
- Built-in large-capacity memory, the test data of the inspected equipment can be quickly saved on site.
- After the calibration work is completed, the original data can be exported to the computer through the U disk for sorting and analysis.
|
☆ APP graphical and intuitive display |
|
S/N |
Function description |
1 |
AC power measurement has an oscilloscope function that displays the waveform of the AC signal under test in real time. |
2 |
Calculate two types of harmonic distortion: THD/T (harmonic relative to full wave) and THD/F ( harmonic relative to fundamental wave). |
3 |
The amplitude (RMS), content (%) and phase of the 2nd~128th harmonic of voltage or current can be analyzed in real time. |
4 |
Visualize the spectrum of each harmonic in the form of a histogram (100% fundamental). |
☆ Data statistical analysis |
|
S/N |
Function description |
1 |
Visual display of the measured power: The measured voltage and current measurement results are displayed at the same time |
2 |
Power Trend Test: Curve the power over time in real time during the test cycle. |
3 |
Power stability analysis: calculate the maximum (MAX), minimum value (min), and peak-peak value of the measured electricity ( P-P ), mean ( Avg ) , standard deviation ( S.dev ) , divergence ( Div ), etc. |
5. Specifications
5.1 AC/DC voltage measurement
Voltage range |
Resolution |
Measurement uncertainty (k=2). ( ppm*RD+ppm*RG)[1] |
Temperature coefficient ppm*RD /ºC @ ( 15~30 ) ºC |
Class 0.1 |
Class 0.05 |
Class 0.1 |
Class 0.05 |
50 V |
100 μV |
600 + 400 |
300 + 200 |
<20 |
<10 |
150 V |
1 mV |
600 + 400 |
300 + 200 |
<20 |
<10 |
500 V[2] |
1 mV |
600 + 400 |
300 + 200 |
<20 |
<10 |
Note [1]: RD is the reading value, RG is the range value, the same below. Note [2]: The 500 V range is optional, other ranges can be customized upon request. |
- Measuring range: 5 V~1 8 0 V or 5 V~500 V (optional), direct measurement, manual or automatic range switching
- Measurement band: DC, 40 Hz~1 kHz
5.2AC/DC current measurement
Current measurement selection [3]. |
Range |
Resolution |
Measurement uncertainty (k=2). ( ppm*RD+ppm*RG)[1] |
Class 0.1 |
Class 0.05 |
TK6700-500A |
100 A,500 A |
1 mA |
600 + 400 |
300 + 200 |
TK6700-1kA[4] |
200 A,1 kA |
10 mA |
600 + 400 |
300 + 200 |
Note [3]: Users can choose the calibrator of the corresponding specification according to their needs. Other current ranges can be customized by customers. Note [4] TK6 700-x2 type, built-in load is 600A, if you need to complete the current measurement above 600A, you need to cascade a TK6400. |
- Measuring range: 10 A... 1 kA, manual or automatic range switching
- Measurement frequency: DC, 40 Hz~1 kHz
6. General Specifications
Power supply |
AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz |
Temperature performance |
Working temperature: 0°C~45°C; Storage temperature: -20 °C ~ 70 °C |
Humidity performance |
Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C Storage humidity: (20%~80%) R· H, no condensation |
altitude |
< 3000 m |
Communication interface |
USB,LAN |
7. Ordering Information
Company Profile