TK4830 Portable Tester for EV DC/AC Charging Station
Test Method 2: Test with programmable resistive load as load
![]() |
|
![]() |
| DC CCS2 | AC Mennekes(Type2) | DC CHAdeMO |
| DC Measurement Function | |||||
| DC Voltage | Measuring Range | 200 V~1000 V | |||
| Measurement Uncertainty (k=2) | 0.025%*RD | ||||
| DC Current | Measuring Range | 1 A~300 A | |||
| Measurement Uncertainty(k=2) | 5 A ≤ I ≤ 300 A | 0.025%*RD | |||
| 1 A ≤ I<5 A | 0.05%*RD | ||||
| Power/Energy | Measurement Uncertainty(k=2) | 5 A ≤ I ≤ 300 A | 0.05%*RD | ||
| 1 A ≤ I<5 A | 0.1%*RD | ||||
| AC Measurement Function | |||||
| AC Voltage | Measuring Range | three-phase 200V~480V | |||
| Measurement Uncertainty (k=2) | 0.025%*RD | ||||
| AC Current | Measuring Range | three-phase 0.1 A~80 A | |||
| Measurement Uncertainty(k=2) | 0.025%*RD | ||||
| Power/Energy | Measurement Uncertainty(k=2) | 0.05%*RD | |||
| Clock Function | |||||
| Clock | Timing mode | GPS Clock timing | |||
| Time Error | ≤1s | ||||
| Temperature Function | |||||
| Temperature | Measurement Range | -30ºC~60ºC | |||
| Maximum Permissible Error | 0.5ºC | ||||
| General Specifications | |||||
| Power Supply Mode | (1)Utility power: support 85V~265V,47Hz~63Hz; (2)Charging gun head takes power (3)Removable built-in lithium battery |
||||
| Communication Interface | USB,LAN,Bluetooth or WiFi | ||||
| Temperature Performance | Operating temperature: -25°C~55°C; Storage temperature: -30°C~70°C |
||||
| Humidity Performance | Operating humidity: < 80% @ 30°C, < 70% @ 40°C. < 40% @ 50°C Storage humidity: <80% R·H, non-condensing |
||||