TD2550 Non-touch Static Voltmeters Calibration Device

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 12 Months Excellent After-Sales Service
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013
  • TD2550 Non-touch Static Voltmeters Calibration Device
  • TD2550 Non-touch Static Voltmeters Calibration Device
  • TD2550 Non-touch Static Voltmeters Calibration Device
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD2550
Application
Electromagnetic Instrument, Electrical Calibration
Power
Electricity
Voltage Output
/
LCD Display
With LCD Display
Customized
Non-Customized
Bipolar DCV output
500 V ~ 20 kV (30kV is customable)
Protection
Short-circuit and overload protection
Interface
RS232
Transport Package
Package for Exporting
Specification
20kg, 520mm (W)x 530mm (D) x910mm (H)
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
100.00cm * 100.00cm * 200.00cm
Package Gross Weight
62.000kg

Product Description

               TD2550 Calibration Apparatus for Non-touch Static Voltmeters
TD2550 Non-touch Static Voltmeters Calibration Device

1. Summary

TD2550 is a high precision, high stability high pressure standard source instrument. It can output DCV up to 20 kV(30kV is customizable). It's applied for calibrating non-contact electrostatic voltmeter, high voltage electrostatic voltmeter, DC high voltage meter, high voltage probe etc.

 

2. Features

  1. Bipolar DCV output: 500 V ~ 20 kV (30kV is customable).
  2. With standard plate electrode, insulated support, and a device with a distance regulator.
  3. Equip with standard plate electrode.
  4. Equip with insulation support with distance regulator.
  5. Voltage indicators for safety warning.
  6. Short-circuit and overload protection.
  7. LCD touch screen
  8. RS232 interface
 

3. Application

 
Calibrate Non-Touch Static Voltmeters
TD2550 Non-touch Static Voltmeters Calibration Device
  1. DC voltage (DCV) output: 500 V ~ 20 kV (30 kV can be customized)
  2. Plate electrode: 500 mm 500 mm 2 mm
  3. Max distance: anterior and posterior 300 mm, up and down 30 mm
  4. Apply to the calibration of non-touch static voltmeters.
 

4. Characteristics

Bipolar Output
TD2550 Non-touch Static Voltmeters Calibration Device
  1. TD2500 designed for bipolar, and program controlled output negative polarity DC voltage.
Multiple Output Mode
TD2550 Non-touch Static Voltmeters Calibration Device
  1. "Direct output"mode,User can set output value by touch screen.
TD2550 Non-touch Static Voltmeters Calibration Device
  1. Touch "Calibraion point"of screen for "% setting".
 
Distance Regulator
TD2550 Non-touch Static Voltmeters Calibration Device
  1. With a digital distance regulator, which can move backwards and forwards, up and down.
  2. Max distance: anterior and posterior 300 mm, up and down 30 mm

5. Specifications

5.1 HV output

Range Resolution Stability
 (%/min)
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (mA)
Class 0.1 Class 0.05 Class 0.1 Class 0.05
5 kV 10 mV 0.03 0.02 600 + 400 300 + 200 1.5
20 kV 100 mV 0.03 0.02 600 + 400 300 + 200 1.5
30 kV[2] 100 mV 0.03 0.02 600 + 400 300 + 200 1.0
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%).
Note [2] : 30 kV is optional model.
  1. Output range: 500 V ~ 30 kV, 6 digits display, fineness: 0.002%*RG.
  2. Load impact: Change in accuracy from no load to full load <0.01%*RG.
  3. Protection: arc protection, short circuit protection, and overload protection.
  4. Ripple coefficient: ≤ 0.2%.
 

5.2 Mechanical structural characteristics

  1. Plate electrode (aluminum) size: 500 mm × 500 mm × 2 mm (width × height × thickness).
  2. Distance regulator: moves anterior and posterior, up and down.
  3. Max distance: anterior and posterior 300 mm, up and down 30 mm
  4. Device can hold non-contact electrostatic voltmeters width from 55 mm to 95 mm.
 

6. General Specifications

Power Supply AC (220±22) V,(50 ± 2) Hz
Temperature Working temperature:0°C~45°C;
Storage temperature:-20°C~70°C
Humidity Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C
Storage humidity:(20%~80%) R·H,non-condensing
Interface RS232 interface
 

7. Ordering Information

 
TD2550 Non-touch Static Voltmeters Calibration Device
Company Profile
 

TD2550 Non-touch Static Voltmeters Calibration Device

TD2550 Non-touch Static Voltmeters Calibration DeviceTD2550 Non-touch Static Voltmeters Calibration Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier