Advanced TI1100 Current Calibrator for Electrical Testing Solutions

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 12 months Excellent After-sales Service
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013
  • Advanced TI1100 Current Calibrator for Electrical Testing Solutions
  • Advanced TI1100 Current Calibrator for Electrical Testing Solutions
  • Advanced TI1100 Current Calibrator for Electrical Testing Solutions
  • Advanced TI1100 Current Calibrator for Electrical Testing Solutions
  • Advanced TI1100 Current Calibrator for Electrical Testing Solutions
  • Advanced TI1100 Current Calibrator for Electrical Testing Solutions
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TI1100
Application
Electromagnetic Instrument, Electrical Calibration
Customized
Non-Customized
ACV/DCV output
10 uA ~ 10.5 A
Interface
RS232; LAN; USB
Transport Package
Package for Exporting
Specification
5kg; 215 mm (W) x 252 mm (D) x 88 mm(H),
Trademark
TUNKIA
Origin
China

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 10.00cm
Package Gross Weight
9.000kg

Product Description

                          TI1100 Precision AC/DC Current Calibrator Advanced TI1100 Current Calibrator for Electrical Testing Solutions

1. Summary

TI1100 is an AC/DC current source with high stability and precision, it is applied for calibrating ammeters on-site, e.g, industrial production lines, etc.
 

2. Features

  1. AC\DC current output: 10 μA ~ 10.5 A
  2. Standard version (TI1100-B) and advanced version (TI1100-C) are available
  3. Typical specifications of the standard version (TI1100-B):
          Frequency: DC, AC 10 Hz ~ 2 kHz.
         Typical short-term stability: 0.01%/min
         Optimum Accuracy: DC 0.02, AC 0.05.
     4. Typical specifications of the advanced version (TI1100-C):
         Frequency: DC, AC 10 Hz ~ 10 kHz
         Typical short-term stability: 0.005%/min
         Optimum Accuracy: DC 0.01, AC 0.02.
    5. Shortcut output keys.
    6. Programmable calibration schemes.
    7. RS232, LAN and USB communication interfaces.

3. Application


Calibration for current measuring instruments
Advanced TI1100 Current Calibrator for Electrical Testing Solutions
  1. Suitable for calibrating AC/DC ammeters or current measurement of multimeter.
 
 
  • Convenient operation
Advanced TI1100 Current Calibrator for Electrical Testing Solutions
  1. The front panel has 10 shortcut keys that can output the corresponding value on the screen with one key.
 
  • Calibration Scheme Setting
Advanced TI1100 Current Calibrator for Electrical Testing Solutions
  1. Multiple calibration schemes can be edited and stored for the calibration of multimeter with different specifications.


 

4. Specifications (TI1100-B)

4.1 DC Current Output

Range Current Output Resolution Short term stability (%/min) Accuracy
±(%*output +μA)
Compliance Voltage (V)
300 μA ±(10.0000 μA ~ 330.0000 μA) 100 pA 0.02 0.012 + 0.03 11 V
3 mA ±(0.300000 mA ~ 3.300000 mA) 1nA 0.01 0.012 + 0.24 11 V
30 mA ±(3.00000 mA ~ 33.00000 mA) 10 nA 0.01 0.012 + 2.4 9 V
300 mA ±(30.0000 mA ~ 330.0000 mA) 100 nA 0.01 0.012 + 24 7 V
1A ±(0.100000 A ~ 1.100000 A) 1μA 0.01 0.012 + 80 6 V
10 A ±(1.00000 A ~ 10.50000 A) 10 μA 0.01 0.012 + 800 4 V
  1. Output range: ± (10 μA ~ 10.5 A).
  2. 7 digits display.
  3. Adjustment fineness: 0.002% * RG.
  4. Ripple coefficient:<0.1%.
  5. Protection function: open circuit protection, overload protection, overheating protection.
 

4.2 AC Current Output

Range Current Output Frequency Resolution Accuracy
±(%*output +μA)
Compliance Voltage (rms)
300 μA 10.0000 μA ~ 330.0000 μA 10 Hz ~ 45 Hz 100 pA 0.05 + 0.2 7 V
45 Hz ~ 400 Hz 0.03 + 0.1
400 Hz ~ 2 kHz 0.04 + 0.2
3 mA 0.300000 mA ~ 3.300000 mA 10 Hz ~ 45 Hz 1nA 0.05 + 0.5 7 V
45 Hz ~ 400 Hz 0.03 + 0.3
400 Hz ~ 2 kHz 0.04 + 0.5
30 mA 3.00000 mA ~ 33.00000 mA 10 Hz ~ 45 Hz 10 nA 0.05 + 5 6 V
45 Hz ~ 400 Hz 0.03 + 3
400 Hz ~ 2 kHz 0.04 + 5
300 mA 30.0000 mA ~ 330.0000 mA 10 Hz ~ 45 Hz 100 nA 0.05 + 50 5 V
45 Hz ~ 400 Hz 0.03 + 30
400 Hz ~ 2 kHz 0.04 + 50
1A 0.100000 A ~ 1.100000 A 10 Hz ~ 45 Hz 1μA 0.05 + 150 4 V
45 Hz ~ 400 Hz 0.03 + 100
400 Hz ~ 2 kHz 0.04 + 150
10 A 1.00000 A ~ 10.50000 A 45 Hz ~ 400 Hz 10 μA 0.03 + 1000 2.5 V
400 Hz ~ 2 kHz 0.04 + 1500
  1. Output range: ± (10 μ A ~ 10.5 A).
  2. 7 digits display.
  3. Adjustment fineness: 0.002% * RG.
  4. Distortion: <0.3%.
  5. Protection function: open circuit protection, overload protection, overheating protection.
 

4.3 Frequency

Range Resolution Accuracy (± %*RD)
10.00000 Hz ≤ F ≤ 99.99999 Hz 0.01 mHz 0.01
100.0000 Hz ≤ F ≤ 999.9999 Hz 0.1 mHz 0.01
1.000000 kHz ≤ F ≤ 2.000000 kHz 1 mHz 0.01
 

5. Specifications (TI1100-C)

5.1 DC Current Output

Range Current Output Resolution 24-hour Stability (Tcal±1°C) Accuracy
1year(Tcal±5°C)
Compliance Voltage
±(ppm*output + μA)
100 μA ±(10.0000 μA ~ 110.0000 μA) 100 pA 50 + 0.01 100 + 0.02 10 V
1 mA ±(0.100000 mA ~ 1.100000 mA) 1nA 40 + 0.02 80 + 0.04 10 V
10 mA ±(1.00000 mA ~ 11.00000 mA) 10 nA 30 + 0.2 60 + 0.4 9 V
100 mA ±(10.0000 mA ~ 110.0000 mA) 100 nA 30 + 2 60 + 4 7 V
1 A ±(0.100000 A ~ 1.100000 A) 1 μA 30 + 20 60 + 40 4 V
10 A ±(1.00000 A ~ 10.50000 A) 10 μA 50 + 300 100 + 500 4 V
  1. Output range: ± (10 μA ~ 10.5 A).
  2. 7 digits display.
  3. Adjustment fineness: 0.002% * RG.
  4. Ripple coefficient: <0.1%.
  5. Protection function: open circuit protection, overload protection, overheating protection
 

5.2 AC Current Output

Range Current Output Frequency Resolution Accuracy
 ±(%*output +μA)
Compliance Voltage (rms)
100 μA 10.0000 μA ~ 110.0000 μA 10 Hz ~ 45 Hz 100 pA 800 + 0.04 6.5V
45 Hz ~ 2 kHz 600 + 0.04
2 kHz ~ 10 kHz 800 + 0.1
1 mA 0.100000 mA ~ 1.100000 mA 10 Hz ~ 45 Hz 1 nA 300 + 0.1 6.5V
45 Hz ~ 2 kHz 200 + 0.1
2 kHz ~ 10 kHz 300 + 0.2
10 mA 1.00000 mA ~ 11.00000 mA 10 Hz ~ 45 Hz 10 nA 200 + 0.8 6 V
45 Hz ~ 2 kHz 120 + 0.8
2 kHz ~ 10 kHz 300 + 2
100 mA 10.0000 mA ~ 110.0000 mA 10 Hz ~ 45 Hz 100 nA 200 + 8 5 V
45 Hz ~ 2 kHz 120 + 8
2 kHz ~ 10 kHz 300 + 20
1 A 0.100000 A ~ 1.100000 A 10 Hz ~ 45 Hz 1μA 200 + 80 3.5 V
45 Hz ~ 2 kHz 120 + 80
2 kHz ~ 10 kHz 300 + 200
10 A 1.00000 A ~ 10.50000 A 10 Hz ~ 45 Hz 10 μA 200 + 1000 2.5 V
45 Hz ~ 2 kHz 120 + 1000
2 kHz ~ 5 kHz 300 + 2000
  1. Output range: ± (10 μA ~ 10.5 A).
  2. 7 digits display.
  3. Adjustment fineness: 0.002% * RG.
  4. Distortion:<0.5%
  5. Protection function: open circuit protection, overload protection, overheating protection.
 

5.3 Frequency

Range Resolution Accuracy (± %*RD)
10.00000 Hz ≤ F ≤ 99.99999 Hz 0.01 mHz 0.01
100.0000 Hz ≤ F ≤ 999.9999 Hz 0.1 mHz 0.01
1.000000 kHz ≤ F ≤ 9.999999 kHz 1 mHz 0.01
10.00000 kHz 10 mHz 0.01
 

6. General Specifications

Power supply AC (220±22) V,(50±2) Hz
Maximum power consumption 100 VA
Warm up time Twice the time since last warmed up, to a maximum of 30 minutes.
work environment 0 ° C~55 ° C, 30% R · H~80% R · H, non-condensing
Storage environment -30 ° C~70 ° C, 10% R · H~90% R · H, non-condensing
Communication interface USB×1,LAN×1,RS232×1
Dimensions 215 mm (width) x 252 mm (depth) x 88 mm (height), excluding feets.
Display 3.5-inch color LCD
Weight About 5 kg
 
Company Profile
 

Advanced TI1100 Current Calibrator for Electrical Testing Solutions

Advanced TI1100 Current Calibrator for Electrical Testing SolutionsAdvanced TI1100 Current Calibrator for Electrical Testing Solutions


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier