Customization: | Available |
---|---|
After-sales Service: | Life Time |
Warranty: | 12 Months Excellent After Service |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
☆ Calibrate single three-phase power source /meter |
|
☆Comprehensive Analysis of AC power |
|
S/N | Function |
1 | The measuring channel has the function of oscilloscope, which can display the waveform of the measured power in real time. |
2 | Accurately measure the phase between the voltage and current of each phase, and visually display it through the form of phasor diagram. |
3 | Two types of harmonic distortion, THD/T (harmonic relative to full wave) and THD/F (harmonic relative to fundamental wave), are calculated. |
4 | The amplitude (RMS), content (%) and phase of the 2nd ~ 127th harmonic wave of each phase voltage or current can be analyzed in real time.; It is used to check whether the harmonic content and phase of complex waveform output of R46 device meet the requirements of the regulation. |
5 | The spectrum of each harmonic is visually displayed in the form of a bar chart (the fundamental wave is 100%). |
☆Data statistical analysis function |
|
S/N | Function |
1 | Statistical analysis of data: calculate the maximum value (Max), minimum value (Min), peak-peak value (P-P), average value (Avg), standard variance (S.dev), etc. |
2 | Power stability test: In the test cycle, real-time plot the curve of power change with time. |
3 | Normal distribution histogram: Displays the distribution of the collected power within a test period. |
4 | Power stability test: According to the algorithm of JJG 597-2005 "Verification Regulation of AC Watt-hour Meter Verification Device", the output power stability of the inspected electric energy device can be calculated automatically. |
Range | Resolution | Measurement uncertainty ( k = 2 ) ( ppm*RD + ppm*RG ) [1] |
Temperature coefficient @ (15~30)°C (ppm*RD+ppm*RG) /°C |
60 V | 10 μV | 30 + 20 | 0.25 + 0.25 |
120 V | 0.1mV | 30 + 20 | 0.25 + 0.25 |
240 V | 0.1mV | 30 + 20 | 0.25 + 0.25 |
480 V | 0.1mV | 30 + 20 | 0.25 + 0.25 |
Note [1]: RD is the reading value, RG is the range value, the same below. |
Range | Resolution | Measurement uncertainty at different frequencies (Hz) (k = 2). ( ppm*RD + ppm*RG ) |
Temperature coefficient @ (15~30)°C (ppm*RD+ppm*RG) /°C |
||
45 ≤ F ≤ 65 | 65 < F ≤ 200 | 200 < F ≤ 400 | |||
5 mA | 1 nA | 120 + 80 | 240 + 160 | 480 + 320 | 5 + 5 |
10 mA | 10 nA | 60 + 40 | 120 + 80 | 240 + 160 | 3 + 3 |
20 mA | 10 nA | 60 + 40 | 120 + 80 | 240 + 160 | 0.75 + 0.75 |
50 mA | 10 nA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
100 mA | 0.1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
200 mA | 0.1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
500 mA | 0.1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
1 A | 1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
2 A | 1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
5 A | 1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
10 A | 10 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
20 A | 10 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
50 A | 10 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
100 A | 100 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
Measurement type | TD3310 | TD3310-R | ||
Frequency | Measuring range | 45 Hz~65 Hz | 45 Hz~400 Hz | |
Minimum resolution | 0.000 01 Hz | 0.000 01 Hz | ||
Measurement uncertainty (k=2) | 0.005%*RD | 0.005%*RD | ||
Phase | Measuring range | 0~360°(I ≥ 50mA) | 0~360°(I ≥ 50mA) | |
Minimum resolution | 0.000 1° | 0.000 1° | ||
Measurement uncertainty (k=2) | 45 Hz ≤ F ≤ 65 Hz | 0.003° | 0.003° | |
65 Hz < F ≤ 200 Hz | -- | 0.01° | ||
200 Hz < F ≤ 400 Hz | -- | 0.02° |
Voltage range | Current range | Factor | Measurement uncertainty at different frequencies (Hz) (k=2) | ||
45 ≤ F ≤ 65 | 65 < F ≤ 200 | 200 < F ≤ 400 | |||
30 V ≤ U ≤ 480 V | 50 mA ≤ I ≤120 A | 0.5L~1~0.5C | 0.01%*RD | 0.02%*RD | 0.04%*RD |
10 mA ≤ I < 50 mA | 1 | 0.01%*RD | 0.03%*RD | 0.08%*RD | |
0.5L~1~0.5C | 0.02%*RD | ||||
3 mA ≤ I < 10 mA | 1 | 0.02%*RD | - | - | |
0.5L~1~0.5C | 0.04%*RD | - | - | ||
0.2 mA ≤ I < 3 mA | 1 | 0.02%*RD×3mA/I | - | - |
Power supply | AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz |
Maximum power consumption | 60 VA |
Warm-up time | 30 minutes |
Temperature performance | Working temperature: 5°C~45°C; Storage temperature: -10 °C ~ 55 °C |
Humidity performance | Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C Storage humidity: (20%~80%) R· H, no condensation |
altitude | < 3000 m |
Quality | Approx. 9.1 kg |
Communication interface | RS232,USB,LAN |
Size | 390 mm(W) × 271 mm(D) × 195 mm(H) |