☆ Assessment of AC Power Measurement Standards |
On-site assessment of single-phase electric energy meter calibration devices and single-phase standard electric energy meters that meet the R46 directive for level 0.02 and below |
☆ Calibrate Single-phase Power Source/Meter |
Suitable for calibrating single/three-phase power sources, power meters/standard energy meters of level 0.02 and below (requires a stable power source). |
☆ Comprehensive Analysis of AC Power | |
S/N | Function |
1 | Oscilloscope function: Display the waveform of the measured power in real time. |
2 | Accurately measure the phase between each phase voltage and current, and display it intuitively in the form of a phasor diagram. |
3 | Calculate two types of harmonic distortion: THD/T (harmonic relative to full wave) and THD/F (harmonic relative to fundamental). |
4 | The amplitude (RMS), content (%), and phase of the 2nd to 63rd harmonics of each phase voltage or current can be analyzed in real time. |
5 | The spectrum of each harmonic is visually displayed in the form of a histogram (the fundamental wave is 100%). |
☆ Data statistical Analysis Function | |
S/N | Function |
1 | Data statistical analysis: calculate the maximum (Max), minimum value (min), peak-to-peak (P-P), average value (AVG), standard deviation (S.dev), etc. of the measured electricity. |
2 | Powe Stability Test: curve the amount of electricity over time in real time. |
3 | Normal distribution histogram: displays the distribution of the amount of electricity. |
4 | Power stability test: automatically measure the output power stability of the tested energy device according to the algorithm of JJG 597-2005 |
☆ Rich Communication Interface |
Range | Resolution | Measurement Uncertainty ( k = 2 ) ( ppm*RD + ppm*RG ) [1] |
Temperature Coefficient @ (15~30)°C (ppm*RD+ppm*RG) /°C |
60 V | 10 μV | 30 + 20 | 0.25 + 0.25 |
120 V | 0.1mV | 30 + 20 | 0.25 + 0.25 |
240 V | 0.1mV | 30 + 20 | 0.25 + 0.25 |
480 V | 0.1mV | 30 + 20 | 0.25 + 0.25 |
Note [1]: RD is the reading value, RG is the range value, the same below. |
Range | Resolution | Measurement Uncertainty at Different Frequencies ( Hz ) ( k = 2 ) ( ppm*RD + ppm*RG ) |
Temperature Coefficient @ (15~30)°C (ppm*RD+ppm*RG) /°C |
||
45 ≤ F ≤ 65 | 65 < F ≤ 200 | 200 < F ≤ 400 | Class 0.01 | ||
10 mA | 10 nA | 60 + 40 | 120 + 80 | 240 + 160 | 3 + 3 |
20 mA | 10 nA | 60 + 40 | 120 + 80 | 240 + 160 | 0.75 + 0.75 |
50 mA | 10 nA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
100 mA | 0.1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
200 mA | 0.1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
500 mA | 0.1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
1 A | 1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
2 A | 1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
5 A | 1 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
10 A | 10 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
20 A | 10 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
50 A | 10 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
100 A | 100 μA | 30 + 20 | 60 + 40 | 120 + 80 | 0.25 + 0.25 |
Measurement Type | TD3110 | TD3110-R | ||
Frequency | Measuring Range | 45 Hz~65 Hz | 45 Hz~400 Hz | |
Minimum Resolution | 0.000 01 Hz | 0.000 01 Hz | ||
Measurement Uncertainty (k=2) | 0.005%*RD | 0.005%*RD | ||
Phase | Measuring Range | 0~360°(I ≥ 50mA) | 0~360°(I ≥ 50mA) | |
Minimum Resolution | 0.000 1° | 0.000 1° | ||
Measurement Uncertainty (k=2) |
45 Hz ≤ F ≤ 65 Hz | 0.003° | 0.003° | |
65 Hz < F ≤ 200 Hz | -- | 0.01° | ||
200 Hz < F ≤ 400 Hz | -- | 0.02° |
Voltage Range | Current Range | Power Factor | Measurement Uncertainty at Different Frequencies ( Hz ) ( k = 2 ) | ||
45 ≤ F ≤ 65 | 65 < F ≤ 200 | 200 < F ≤ 400 | |||
30 V ≤ U ≤ 480 V | 50 mA ≤ I ≤120 A | 0.5L~1~0.5C | 0.01%*RD | 0.02%*RD | 0.04%*RD |
10 mA ≤ I < 50 mA | 1 | 0.01%*RD | 0.03%*RD | 0.08%*RD | |
0.5L~1~0.5C | 0.02%*RD | ||||
5 mA ≤ I < 10 mA | 1 | 0.02%*RD | -- | -- | |
0.5L~1~0.5C | 0.04%*RD | -- | -- | ||
1 mA ≤ I < 5 mA | 1 | 0.02%*RD×5mA/I | -- | -- |
Power Supply | AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz |
Maximum Power Consumption | 60 VA |
Warm-up Time | 30mins |
Temperature Performance | Working temperature:5°C~45°C; Storage temperature:-10°C~55°C |
Humidity Performance | Working humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C Storage humidity: (20%~80%) R·H, non-condensing |
Altitude | < 3000 m |
Weight | Approx 9 kg |
Communication Interface | RS232,USB,LAN |
Size | 400 mm(W) × 345 mm(D) × 205 mm(H) |