TH0420 reference coaxial shunt with 12 different current ranges for current measurement

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 12 Months Excellent After-Sales Service
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013
  • TH0420 reference coaxial shunt with 12 different current ranges for current measurement
  • TH0420 reference coaxial shunt with 12 different current ranges for current measurement
  • TH0420 reference coaxial shunt with 12 different current ranges for current measurement
  • TH0420 reference coaxial shunt with 12 different current ranges for current measurement
  • TH0420 reference coaxial shunt with 12 different current ranges for current measurement
  • TH0420 reference coaxial shunt with 12 different current ranges for current measurement
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TH0420
Application
Electromagnetic Instrument, Electrical Calibration
Power
Electricity
Voltage Output
1V or 0.5V
Customized
Non-Customized
Nominal input current
0.1A~500A
Nominal output voltage
1V, 0.5V
Working frequency
DC~100kHz
Optimum AC DC difference
5ppm@53Hz, 10ppm@1kHz, 25ppm@100kHz
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Product Description

TH0420 reference coaxial shunt with 12 different current ranges for current measurement
 
1. Summary
TH0420 is A precision coaxial shunt with ultra-low power coefficients. Each set contains A total of 10 different current range specifications and can convert nominal current from 0.1 A to 100 A to nominal voltage output of 1 V or 0.5 V.
TH0420 has a very low power coefficient, such as TH0420-100A even under 100 W power conditions, its power coefficient is not more than 10 PPM, very suitable for a wide range of AC and DC current rapid measurement.

2. Features
Operating frequency: DC ~ 100 kHz
Nominal input current: 0.1A ~ 100A (wider range can be customized)
Nominal output voltage is 1 V or 0.5 V
Annual variation: typical value is 5 ppm, maximum value is 16 ppm.
Ultra low power factor
Can withstand the instantaneous current impact

3. Applications
Build Wide Frequency Current Measurement System
TH0420 reference coaxial shunt with 12 different current ranges for current measurement
TH0420 reference coaxial shunt with 12 different current ranges for current measurement
Set up wideband current measurement system with wideband current source and wideband standard voltmeter (such as TH2000 vector voltage analyzer), measure wideband current signal, and calibrate wideband current source and wideband ammeter, etc.
 
Build Wide Frequency Power/Energy Precision Measurement System
TH0420 reference coaxial shunt with 12 different current ranges for current measurement
Set up wideband power/energy precision measurement system with high frequency V/V conversion standard and TH2000 vector voltage analyzer, measure wideband power/energy signal, calibrate wideband power source, wideband power meter, power analyzer and other equipment.



 
  • Build Wide Frequency Transformer/Sensor Calibration System
 TH0420 reference coaxial shunt with 12 different current ranges for current measurementTH0420 reference coaxial shunt with 12 different current ranges for current measurement
 
Set up a wideband transformer/sensor measurement system with wideband constant-current source and wideband sensor tester (such as TH2000 vector voltage analyzer) to calibrate the tested transformer or sensor with nominal current ≤ 500 A.
  • Build Wide Frequency Transformer/Sensor Calibration System
TH0420 reference coaxial shunt with 12 different current ranges for current measurement
For the calibration of transformer/sensor whose nominal current is greater than 500 A, TH0420 is used as the standard and the secondary signal I/V converter of the equipment under inspection, and a wideband transformer/sensor measurement system is established with a wideband constant current source and a wideband sensor tester (such as TH2000 vector voltage analyzer).

4. Specifications
4.1 Resistance Specification
Specification Nominal resistance ( Ω ) Initial deviation [1]
( ±μΩ/Ω )
@ (23±1)°C
Annual
Stability
( ±μΩ/Ω )
Temperature coefficient ( ppm/K ) Power factor [2]
( ±ppm/Rated power )
TH0420-0.1A 10 30 12 2.0 1
TH0420-0.2A 5 30 12 2.0 1
TH0420-0.5A 2 30 12 2.0 2
TH0420-1A 1 30 12 2.0 3
TH0420-2A 0.5 30 12 2.5 5
TH0420-5A 0.2 30 12 2.5 5
TH0420-10A 0.1 30 12 2.5 5
TH0420-20A 0.05 30 12 2.5 8
TH0420-50A 0.02 30 12 3.0 10
TH0420-100A 0.01 30 12 3.0 10
Note [1]: The initial deviation is the maximum offset of the resistance under DC condition, usually the manufacturer's guaranteed value; Higher precision can be customized according to user requirements, such as 20 μΩ/Ω.
Note [2]: When the coaxial shunt is used to measure DCI, the resistance's own heat will lead to the change of resistance value under different input currents, thus introducing the error. The calculation formula is as follows:
γ= power coefficient × [1-(current measurement/nominal current value)^2]

4.2 Current Measurement
Specification Nominal input current ( A ) Nominal Output current  ( V ) AC/DC difference[3] ( k=2,±ppm )
53 Hz 1 kHz 10 kHz 100 kHz
TH0420-0.1A 0.1 1 20 25 25 25
TH0420-0.2A 0.2 1 20 25 25 25
TH0420-0.5A 0.5 1 20 25 25 25
TH0420-1A 1 1 20 25 25 30
TH0420-2A 2 1 20 30 35 50
TH0420-5A 5 1 20 30 50 80
TH0420-10A 10 1 20 30 50 100
TH0420-20A 20 1 20 30 50 100
TH0420-50A 50 1 30 50 80 150
TH0420-100A 100 1 30 50 100 200
Note [3]: The measured value of AC current should be calculated according to the following formula, and the unit of the difference between AC and DC is ppm:
Ac current measurement value =(voltage measurement value/calibration resistance value)×(1+ AC-DC difference /(1 000 000))
 
Specification Maximum current( A ) Instantaneous current
 (<5s)
Specification Maximum operating current( A ) Instantaneous current
 (<5s)
TH0420-0.1A 0.2 A 1.5 A TH0420-5A 5.5 A 20 A
TH0420-0.2A 0.5 A 2 A TH0420-10A 11 A 30 A
TH0420-0.5A 1 A 3 A TH0420-20A 22 A 50 A
TH0420-1A 1.5 A 4 A TH0420-50A 55 A 100 A
TH0420-2A 2.5 A 6 A TH0420-100A 110 A 200 A

4.3 Phase Displacement
Specification Phase Displacement ( k=2, ±μrad )
53 Hz 400 Hz 1 kHz 10 kHz 50 kHz 100 kHz
TH0420-0.1A 5 5 10 30 150 300
TH0420-0.2A 5 5 10 30 150 300
TH0420-0.5A 5 5 10 30 150 300
TH0420-1A 5 5 10 30 150 300
TH0420-2A 10 10 15 50 300 600
TH0420-5A 10 15 25 100 500 1200
TH0420-10A 10 20 40 150 800 1600
TH0420-20A 10 25 50 200 1000 2000
TH0420-50A 10 30 65 300 1500 3000
TH0420-100A 20 40 80 400 2000 4000
 
5. General Specifications
Power supply --
Temperature performance Operating temperature: 13 °C ~ 33 °C;
Calibration temperature: 18°C~28°C;
Storage temperature: 5 °C to 45 °C
Note: When stored in a harsh temperature environment, the resistance value may change temporarily and be restored to the original resistance value within the following 30 days.
Humidity performance Operating humidity: < 50% r. H
Storage humidity :(15%~80%) R·H, no condensation


6. Ordering Information
TH0420 reference coaxial shunt with 12 different current ranges for current measurement Specification Nominal current
TH0420-0.1A 0.1 A
TH0420-0.2A 0.2 A
TH0420-0.5A 0.5 A
TH0420-1A 1 A
TH0420-2A 2 A
TH0420-5A 5 A
TH0420-10A 10 A
TH0420-20A 20 A
TH0420-50A 50 A
TH0420-100A 100 A
Company Profile
 

TH0420 reference coaxial shunt with 12 different current ranges for current measurement

TH0420 reference coaxial shunt with 12 different current ranges for current measurementTH0420 reference coaxial shunt with 12 different current ranges for current measurement

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier