☆ Build Wide Frequency Current Measurement System |
Set up wideband current measurement system with wideband current source and wideband standard voltmeter (such as TH2000 vector voltage analyzer), measure wideband current signal, and calibrate wideband current source and wideband ammeter, etc. |
☆ Build Wide Frequency Power/Energy Precision Measurement System |
Set up wideband power/energy precision measurement system with high frequency V/V conversion standard and TH2000 vector voltage analyzer, measure wideband power/energy signal, calibrate wideband power source, wideband power meter, power analyzer and other equipment. |
|
|
Set up a wideband transformer/sensor measurement system with wideband constant-current source and wideband sensor tester (such as TH2000 vector voltage analyzer) to calibrate the tested transformer or sensor with nominal current ≤ 500 A. |
|
For the calibration of transformer/sensor whose nominal current is greater than 500 A, TH0420 is used as the standard and the secondary signal I/V converter of the equipment under inspection, and a wideband transformer/sensor measurement system is established with a wideband constant current source and a wideband sensor tester (such as TH2000 vector voltage analyzer). |
Specification | Nominal resistance ( Ω ) | Initial deviation [1] ( ±μΩ/Ω ) @ (23±1)°C |
Annual Stability ( ±μΩ/Ω ) |
Temperature coefficient ( ppm/K ) | Power factor [2] ( ±ppm/Rated power ) |
TH0420-0.1A | 10 | 30 | 12 | 2.0 | 1 |
TH0420-0.2A | 5 | 30 | 12 | 2.0 | 1 |
TH0420-0.5A | 2 | 30 | 12 | 2.0 | 2 |
TH0420-1A | 1 | 30 | 12 | 2.0 | 3 |
TH0420-2A | 0.5 | 30 | 12 | 2.5 | 5 |
TH0420-5A | 0.2 | 30 | 12 | 2.5 | 5 |
TH0420-10A | 0.1 | 30 | 12 | 2.5 | 5 |
TH0420-20A | 0.05 | 30 | 12 | 2.5 | 8 |
TH0420-50A | 0.02 | 30 | 12 | 3.0 | 10 |
TH0420-100A | 0.01 | 30 | 12 | 3.0 | 10 |
Note [1]: The initial deviation is the maximum offset of the resistance under DC condition, usually the manufacturer's guaranteed value; Higher precision can be customized according to user requirements, such as 20 μΩ/Ω. Note [2]: When the coaxial shunt is used to measure DCI, the resistance's own heat will lead to the change of resistance value under different input currents, thus introducing the error. The calculation formula is as follows: γ= power coefficient × [1-(current measurement/nominal current value)^2] |
Specification | Nominal input current ( A ) | Nominal Output current ( V ) | AC/DC difference[3] ( k=2,±ppm ) | |||||
53 Hz | 1 kHz | 10 kHz | 100 kHz | |||||
TH0420-0.1A | 0.1 | 1 | 20 | 25 | 25 | 25 | ||
TH0420-0.2A | 0.2 | 1 | 20 | 25 | 25 | 25 | ||
TH0420-0.5A | 0.5 | 1 | 20 | 25 | 25 | 25 | ||
TH0420-1A | 1 | 1 | 20 | 25 | 25 | 30 | ||
TH0420-2A | 2 | 1 | 20 | 30 | 35 | 50 | ||
TH0420-5A | 5 | 1 | 20 | 30 | 50 | 80 | ||
TH0420-10A | 10 | 1 | 20 | 30 | 50 | 100 | ||
TH0420-20A | 20 | 1 | 20 | 30 | 50 | 100 | ||
TH0420-50A | 50 | 1 | 30 | 50 | 80 | 150 | ||
TH0420-100A | 100 | 1 | 30 | 50 | 100 | 200 | ||
Note [3]: The measured value of AC current should be calculated according to the following formula, and the unit of the difference between AC and DC is ppm: Ac current measurement value =(voltage measurement value/calibration resistance value)×(1+ AC-DC difference /(1 000 000)) |
Specification | Maximum current( A ) | Instantaneous current (<5s) |
Specification | Maximum operating current( A ) | Instantaneous current (<5s) |
TH0420-0.1A | 0.2 A | 1.5 A | TH0420-5A | 5.5 A | 20 A |
TH0420-0.2A | 0.5 A | 2 A | TH0420-10A | 11 A | 30 A |
TH0420-0.5A | 1 A | 3 A | TH0420-20A | 22 A | 50 A |
TH0420-1A | 1.5 A | 4 A | TH0420-50A | 55 A | 100 A |
TH0420-2A | 2.5 A | 6 A | TH0420-100A | 110 A | 200 A |
Specification | Phase Displacement ( k=2, ±μrad ) | |||||
53 Hz | 400 Hz | 1 kHz | 10 kHz | 50 kHz | 100 kHz | |
TH0420-0.1A | 5 | 5 | 10 | 30 | 150 | 300 |
TH0420-0.2A | 5 | 5 | 10 | 30 | 150 | 300 |
TH0420-0.5A | 5 | 5 | 10 | 30 | 150 | 300 |
TH0420-1A | 5 | 5 | 10 | 30 | 150 | 300 |
TH0420-2A | 10 | 10 | 15 | 50 | 300 | 600 |
TH0420-5A | 10 | 15 | 25 | 100 | 500 | 1200 |
TH0420-10A | 10 | 20 | 40 | 150 | 800 | 1600 |
TH0420-20A | 10 | 25 | 50 | 200 | 1000 | 2000 |
TH0420-50A | 10 | 30 | 65 | 300 | 1500 | 3000 |
TH0420-100A | 20 | 40 | 80 | 400 | 2000 | 4000 |
Power supply | -- |
Temperature performance | Operating temperature: 13 °C ~ 33 °C; Calibration temperature: 18°C~28°C; Storage temperature: 5 °C to 45 °C Note: When stored in a harsh temperature environment, the resistance value may change temporarily and be restored to the original resistance value within the following 30 days. |
Humidity performance | Operating humidity: < 50% r. H Storage humidity :(15%~80%) R·H, no condensation |
Specification | Nominal current | |
TH0420-0.1A | 0.1 A | |
TH0420-0.2A | 0.2 A | |
TH0420-0.5A | 0.5 A | |
TH0420-1A | 1 A | |
TH0420-2A | 2 A | |
TH0420-5A | 5 A | |
TH0420-10A | 10 A | |
TH0420-20A | 20 A | |
TH0420-50A | 50 A | |
TH0420-100A | 100 A |