TH0800 Wiring AC I/V transfer standard

Product Details
Customization: Available
Resistance: Accuracy:30ppm
Function for Resistance: Shunt Resistor, Sampling Resistor
Still deciding? Get samples of US$ 5000/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013
  • TH0800 Wiring AC I/V transfer standard
  • TH0800 Wiring AC I/V transfer standard
  • TH0800 Wiring AC I/V transfer standard
  • TH0800 Wiring AC I/V transfer standard
  • TH0800 Wiring AC I/V transfer standard
  • TH0800 Wiring AC I/V transfer standard
Find Similar Products

Basic Info.

Model NO.
TH0800
Application
Metrology Calibration
Input Current
0.1A ~ 1ka
Output Voltage
1V
Frequency Range
DC~2.5kHz
DC Ratio Accuracy
10ppm
Phase Displacement
5μrad
Trademark
TUNKIA
Origin
Chn
HS Code
9030339000
Production Capacity
500 Set/Year

Product Description

TH0800 Wiring AC I/V transfer standard

TH0800 Wiring AC I/V transfer standard
TH0800 Wiring AC I/V transfer standard
Introduction
  1. TH0800 contains 14 I/V high-precision AC current transfer standard with different ranges, are divided into A, B two versions according to the accuracy.
  2. TH0800 can work in the 40 Hz ~ 2.5 kHz frequency range, converting 10 mA ~ 1 kA nominal current into 1V small voltage.
  3. AC ratio accuracy: 30 ppm(TH0800A) or 10 ppm(TH0800B).
  4. It is convenient to be connected into the large current loop with wiring structure. The secondary output can be equipped with high-precision voltmeter to achieve high-precise measurement of current.
  5. It is suitable for calibration of AC high current source, current sensor/transformer, and other occasions where AC current needs to be measured precisely.
  6. TH0800 can be used with broadband V/V voltage divider, voltage vector analyzer to set up high-precision AC power/energy measurement system.
  7. The equipment is of passive structure, good stability and reliability, suitable for carrying to the site.

Specification
Model Primary Inom (A) Secondary Unom (V) Best Ratio Measurement Accuracy (ppm*FS)
TH0800A TH0800B
TH0800X-100mA 0.1 1 30 10
TH0800X-200mA 0.2 1 30 10
TH0800X-500mA 0.5 1 30 10
TH0800X-1A 1 1 30 10
TH0800X-2A 2 1 30 10
TH0800X-5A 5 1 30 10
TH0800X-10A 10 1 30 10
TH0800X-20A 20 1 30 10
TH0800X-50A 50 1 30 10
TH0800X-100A 100 1 30 10
TH0800X-200A 200 1 30 10
TH0800X-500A 500 1 30 10
TH0800X-1kA 1k 1 30 10
Remarks:  FS is full-scale value
  1. Measurement range:(1%~120%)*FS.




TH0400 Precision Coaxial Shunt

TH0800 Wiring AC I/V transfer standard

Introduction
  1. TH0400, a series of 14 various ranges precision coaxial shunts.
  2. TH0400 can work in the DC ~ 100 kHz frequency range, converting 1 mA ~ 100 A nominal current into 1 V small current.
  3. DC ratio accuracy: 20 ppm;AC/DC difference: 20 ppm; phase displacement: 5.
  4. It is suitable for calibration of AC/DC high current source, current sensor, DC shunt, and other occasions where current needs to be measured precisely.

Features
  1. The nominal voltage is 1 V, can measure current by directly matching high-precision voltmeters or other measurement instruments.
  2. For 1 mA, 10 mA and other high resistance current shunts, combine with the model TH0600 to avoid errors caused by wire connection or input impedance drops of digital meters at high frequency.
  3. Compared to 0.5 V, 0.8 V and other voltage value, the 1V nominal voltage has a higher noise ratio, easier current conversion, faster error calculation, and accords with the 1-2-5 sequence principle of modern measurement.
  4. Precision components and production processes ensure the resistance value stable, the typical resistance change value is ±5 μΩ/Ω in 1 year, and the maximum resistance change value is ±16 μΩ/Ω in 1 year.
  5. Good heat dissipation, lower temperature coefficient and self-heating power factor ensure a good stability.
  6. Small phase displacement between the input current and the sampled voltage, the phase displacement is less than 0.0015 ° even at 1 kHz. This feature is critical for the measurement of non-sinusoidal and wideband signals, applied to analyze power quality and calibrate digital power meters.
  7. The capacity of loading current and withstanding current impulse is limited, but you can use a set of shunts to obtain a wide range of current measurement.

Specification
Resistance
Inom Unom
(V)
Rnom
(Ω)
Initial Deviation (μΩ/Ω) Stability
(μΩ/Ω)
Temperature Coefficient
(ppm/K)
Power Coefficien
(μΩ/Ω)
Imax Load Instantaneous Current (<5 s)
1 mA 1 1 k 50 18 2.5 1 2 mA 3 mA
10 mA 1 100 50 18 2.5 1 20 mA 50 mA
20 mA 1 50 50 18 2.5 1 40 mA 100 mA
50 mA 1 20 50 18 2.5 1 100 mA 200 mA
100 mA 1 10 50 18 2.5 2 200 mA 500 mA
200 mA 1 5 50 18 2.5 4 500 mA 1 A
500 mA 1 2 50 18 2.5 12 1 A 2 A
1 A 1 1 50 18 4.0 25 1.5 A 4 A
2 A 1 0.5 50 18 4.0 25 2.5 A 5 A
5 A 1 0.2 50 18 4.0 30 5.5 A 10 A
10 A 1 0.1 50 18 4.0 60 11 A 25 A
20 A 1 0.05 50 18 4.0 75 22 A 40 A
50 A 1 0.02 50 18 4.5 100 55 A 90 A
100 A 1 0.01 50 18 4.5 100 110 A 180 A
  1. Remarks:
: In the calibration temperature environment, the deviation of the measured resistance value from the nominal resistance value after the rated DC current is applied for ten minutes. Higher precision can be customized according to user requirements, such as: 20μΩ/Ω.
: The initial deviation of the DC resistance value has included the power coefficient influence error under the nominal current. When measuring other non-nominal currents, additional measurement accuracy should be introduced. The calculation formula is:

Current
Inom Max. AC/DC Diff. (ppm*FS) Max. Phase Displacement (μrad)
50 Hz 1 kHz 100 kHz 53 Hz 400 Hz 1 kHz 10 kHz 50 kHz 100 kHz
1 mA 25 50 150 10 10 15 120 500 1000
10 mA 20 25 50 5 5 10 100 400 800
20 mA 20 25 50 5 5 10 100 400 800
50 mA 20 25 50 5 5 10 100 400 800
100 mA 20 25 25 5 5 10 60 300 500
200 mA 20 25 25 5 5 10 60 300 500
500 mA 20 25 25 5 5 10 60 300 500
1 A 20 25 30 5 5 10 60 300 500
2 A 20 30 50 10 10 15 110 500 1000
5 A 20 30 80 10 15 25 200 1000 2000
10 A 25 30 100 10 20 40 300 1500 3000
20 A 25 30 100 10 25 50 400 2000 4000
50 A 30 50 150 10 30 65 500 2500 5000
100 A 30 50 200 20 40 80 600 3000 6000
Remarks: : FS is full-scale value


Dimension and Weight
Model Name Dimension
(W × H × D, mm)
Weight (kg)
TH0400 - 1 mA 1 mA shunts 90 × 25 × 25 0.1
TH0400 - 10 mA 10 mA shunts 90 × 25 × 25 0.1
TH0400 - 20 mA 20 mA shunts 90 × 25 × 25 0.1
TH0400 - 50 mA 50 mA shunts 90 × 25 × 25 0.1
TH0400 - 100 mA 100 mA shunts 90 × 25 × 25 0.1
TH0400 - 200 mA 200 mA shunts 110 × 70 × 70 0.2
TH0400 - 500 mA 500 mA shunts 110 × 70 × 70 0.2
TH0400 - 1 A 1 A shunts 110 × 70 × 70 0.2
TH0400 - 2 A 2 A shunts 110 × 70 × 70 0.2
TH0400 - 5 A 5 A shunts 110 × 70 × 70 0.2
TH0400 - 10 A 10 A shunts 180 × 130 × 130 1
TH0400 - 20 A 20 A shunts 180 × 130 × 130 1
TH0400 - 50 A 50 A shunts 260 × 200 × 200 2.5
TH0400 - 100 A 100 A shunts 260 × 200 × 200 2.5
Remarks: Partial or full purchases are available, particular requirements can be customized by resistance and sampled voltage (e.g. 0.5 V and 0.8V).

TH0230 Wiring AC/DC I/V transfer standard

TH0800 Wiring AC I/V transfer standard
Introduction
  1. TH0230, a series of I/V high-precision AC/DC current transfer standard, are divided into A, B, C, D four versions according to the accuracy.
  2. TH0230 can work in the DC, 10HZ~5kHz frequency range (3dB signal bandwidth ≥100kHz), converting 0.1A ~ 1kA nominal current into 1V small voltage.
  3. AC ratio measurement accuracy: 5 ppm(TH0230D), Best AC ratio measurement accuracy: 100 ppm(TH0230D), supporting positive and negative current measurement.
  4. DC current multi-lap zero adjustment potentiometer and locking device, primary input and secondary output have good electrical isolation, high common mode rejection ratio (CMRR).
  5. It is convenient to be connected into the large current loop with wiring structure. The secondary output can be equipped with high-precision voltmeter to achieve high-precise measurement of current.
  6. It is suitable for calibration of AC/DC high current source/meter (such as calibrator for clamp-meter), current sensor/transformer, electric welder, micro-ohmmeter and other occasions where current needs to be measured precisely.
  7. TH0230 can be used with broadband AC/DC V/V voltage divider, dual-channel voltage vector analyzer to set up high-precision AC/DC power/energy measurement system.

Specification
Model Primary Inom (A) Secondary Unom (V) measurement bandwidth
(kHz)
Best Ratio Measurement Accuracy (ppm*FS)
TH0230A TH0230B TH0230C TH0230D
DC AC@
53Hz
DC AC@
53Hz
DC AC@
53Hz
DC AC@
53Hz
TH0230X-0.1A 0.1 1 30 50 250 25 120 10 120 5 120
TH0230X-0.2A 0.2 1 30 50 250 25 120 10 120 5 120
TH0230X-0.5A 0.5 1 ≥50 50 250 25 120 10 120 5 120
TH0230X-1A 1 1 ≥100 50 200 25 100 10 100 5 100
TH0230X-2A 2 1 ≥100 50 200 25 100 10 100 5 100
TH0230X-5A 5 1 ≥100 50 200 25 100 10 100 5 100
TH0230X-10A 10 1 ≥100 50 200 25 100 10 100 5 100
TH0230X-20A 20 1 ≥100 50 200 25 100 10 100 5 100
TH0230X-50A 50 1 ≥100 50 200 25 100 10 100 5 100
TH0230X-100A 100 1 ≥100 50 200 25 100 10 100 5 100
TH0230X-200A 200 1 ≥100 50 200 25 100 10 100 5 100
TH0230X-500A 500 1 ≥100 50 200 25 100 10 100 5 100
TH0230X-1kA 1k 1 ≥100 50 250 25 120 10 120 7 120
Note : FS is full-scale value
  1. Measurement range:(10%~110%)*FS,positive and negative current measurement;
  2. Measuring frequency:DC,10Hz~5kHz


TH0240 Threading AC/DC I/V transfer standard
TH0800 Wiring AC I/V transfer standard
Introduction
  1. TH0240, a series of I/V high-precision AC/DC current transfer standard, are divided into A, B, C, D four versions according to the accuracy.
  2. TH0230 can work in the DC, 10HZ~5kHz frequency range (3dB signal bandwidth ≥100kHz), converting 200A ~ 10kA nominal current into 1V small voltage.
  3. Best DC ratio measurement accuracy: 5 ppm(TH0240D), Best AC ratio measurement accuracy: 100 ppm(TH0240D), supporting positive and negative current measurement.
  4. DC current multi-lap zero adjustment potentiometer and locking device, primary input and secondary output have good electrical isolation, high common mode rejection ratio (CMRR).
  5. It is convenient to be connected into the large current loop with threading structure. The secondary output can be equipped with high-precision voltmeter to achieve high-precise measurement of current.
  6. It is suitable for calibration of AC-DC high current source/meter (such as calibrator for clamp-meter), current sensor/transformer, electric welder, micro-ohmmeter and other occasions where current needs to be measured.
  7. TH0230 can be used with broadband AC/DC V/V voltage divider, dual-channel voltage vector analyzer to set up high-precision AC/DC power/energy measurement system.
Specification
Model Primary Inom (A) Secondary Unom (V) measurement bandwidth
(kHz)
Best Ratio Measurement Accuracy (ppm*FS)
TH0240A TH0240B TH0240C TH0240D
DC AC@
53Hz
DC AC@
53Hz
DC AC@
53Hz
DC AC@
53Hz
TH0240X-200A 200 1 ≥100 50 200 25 100 10 100 - -
TH0240X-500A 500 1 ≥100 50 200 25 100 10 100 5 50
TH0240X-1kA 1k 1 ≥100 50 200 25 100 10 100 5 50
TH0240X-2kA 2k 1 ≥100 50 200 25 100 10 100 5 50
TH0240X-5kA 5k 1 ≥100 50 200 25 120 10 120 - -
TH0240X-10kA 10k 1 ≥100 50 200 25 150 10 - - -
Note : FS is full-scale value
  1. Measurement range:(10%~110%)*FS,positive and negative current measurement;
  2. Measuring frequency:DC,10Hz~5kHz

TH0800 Wiring AC I/V transfer standard

TH0800 Wiring AC I/V transfer standard
TH0800 Wiring AC I/V transfer standard

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier