Module | Name | Brief introduction |
1 | Single 600A bipolar high current source | The complete system consists of a total of 6 current source cabinets. Each cabinet has three bipolar high-current sources with a maximum output of 600A, for a total of 18 current sources. Each source is equipped with an independent measurement and control module to ensure high current stability and accuracy. The system can output ± bipolar DC high current (100 A~10 kA) through program-controlled output. |
2 | Current source cabinet | |
3 | Sensor test bits | (1) Equipped with a set of sensor test tooling, equipped with a set of four specifications of deflector copper rod, which is convenient for the detection of the through-core sensor. (2) The tooling panel is equipped with a set of sensor output signal tester (support the measurement and measurement of voltage and current signals) and auxiliary power supply interface, which is convenient for users to connect during testing. |
4 | Confluence copper bar | The output current of each current source module is output through a specially designed copper bus. |
5 | Shunt test bits | Includes two high-current test bits for calibration of shunts of different sizes. When one test bit is connected to a DC shunt, the other test bit can be connected to a current ratio standard or shorted using a copper bar. |
6 | Start and emergency stop buttons | Includes power switch and emergency stop button. |
7 | Calibrate the workbench | The calibration bench integrates the following devices: TH1860-100A bipolar superstable constant current source; TH0740A standard resistance measuring device (built-in current, voltage ratio standard); TH0780 Ultra-Precision Current Ratio Extender (Dual Channel); TH0770 standard resistance multiplexer; TH0330 Ultra-stable standard resistance (air type); Measurement console, computer printing. See Figure 4-1 for details. |
Module | Name | Brief introduction |
1 | TH0780 ultra-precision current ratio extender | It has a dual-channel ratio standard, where channel A has a maximum nominal current of 1 00 A, with 1 000:1, 1 00: 1, 1 0:1 three optional ratios; The maximum nominal current of channel B is 1 0 A, with 1 00:1, 1 0:1 two selectable scales. |
2 | TH1860-100A bipolar superstable constant current source | It can output ± (1A~110A) DC current, which is a constant current source with ultra-low noise, high precision, high linearity and better fineness. |
3 | TH0740A standard resistance measuring device | Precise output of ± ( 0 1 mA~1 A) DC current, external standard resistor to achieve precision measurement of 1 Ω~100 kΩ resistance; At the same time, it has the function of precision measurement of dual-channel voltage ratio. |
4 | TH0770 standard resistance multiplexer | According to the calibration requirements, the standard resistors of different specifications that have been connected are programmed to be switched. |
5 | TH0330 ultra-stable standard resistor | Standard resistors of different sizes are connected to the TH0770 and can be programmed to switch when used. |
6 | Measurement console | It can display the standard value of current output, the secondary small signal measurement value of the tested sensor or shunt, the error of the tested sensor or shunt, and the power consumption of the tested sensor in real time. |
7 | Computer | Run the test software, and fully automatic testing can be realized according to user settings after wiring. |
8 | printer | Print the test report. |
Module | Name | Brief introduction |
1 | Quick clamps | The left and right sides are equipped with a set of quick clamps that can be manually opened and clamped with copper rods with a clamping force of 250kg, each with four clamping holes of different diameters. |
2 | Copper rods | According to the size of the test current, different diameters of copper rods are selected, and the sensor is penetrated during the test, which is conducive to forming a uniform magnetic field between the tested and the standard sensor, further reducing the measurement error. Note: Copper rod current specifications: 10 kA, 5 kA, 2 kA, 1kA |
3 | Sensor test bits | It can be penetrated into the penetrated core current sensor and the through-core current proportional extender. |
4 | Low current output | For sensor testing with smaller current specifications. |
5 | Sensor-assisted measurement | (1) The power supply module can output DC ± (5 V~50 V) programmable adjustable voltage It also has the function of loop current and power measurement to detect the power consumption of the sensor. (2) Support the measurement of secondary voltage signal or current signal of the sensor. |
6 | Foldable handwheel | Turn the handwheel sensor platform to lift and move back and forth. |
7 | Sensor platform | It can be controlled by a handwheel to put sensors of different sizes in the appropriate test position. |
Range | Resolution | Short-term stability | Measurement uncertainty (k=2). ppm*RD+ppm*RG |
Maximum load voltage (V) |
|
ppm/min | ppm/h | 1 year | |||
500 A | 100 μA | 2.5 | 8.0 | 30 + 20 | 3 |
1 kA | 1mA | 2.5 | 8.0 | 30 + 20 | 3 |
2 kA | 1mA | 2.5 | 8.0 | 30 + 20 | 3 |
5 kA | 1mA | 2.5 | 8.0 | 30 + 20 | 3 |
10 kA | 10 mA | 2.5 | 8.0 | 30 + 20 | 3 |
current Range |
Resolution ( mA ) |
Short-term stability ppm /min |
Maximum allowable error ± ( ppm*output + ppm*range ) |
|
24 hours | 1 year | |||
10 A | 1 | 0.4 | 5 + 5 | 10 + 5 |
100 A | 10 | 0.4 | 5 + 5 | 10 + 5 |
Product model | Product name | Input current (A) |
Output current (A) |
proportion | accuracy (ppm) |
TH0780-1A | Ultra-precision current proportional extender (integrated in one chassis). |
1 | 0.1 | 10:1 | 0.2 |
TH0780-10A | 10 | 0.1 | 100:1 | 0.2 | |
TH0780-100A | 100 | 0.1 | 1000:1 | 0.5 | |
TH0780-1kA | 1kA ultra-precise current proportional extender | 1,000 | 1 | 1000:1 | 1.5 |
TH0780-3kA | 3kA ultra-precise current proportional extender | 3,000 | 1 | 3000:1 | 3.0 |
TH0780-10kA | 10kA ultra-precise current proportional extender | 10,000 | 1 | 10000:1 | 10 |
Nominal value | Initial deviation ( ppm) |
Temperature coefficient ( ppm /ºC) @23± 5ºC |
Year stability ( ppm ) |
Rated power ( W ) |
Power factor ( ppm /power* ) |
1 H | ± 2 | ± 0.05 | ± 0.2 | 1.0 | ± 1 |
10 Ω | ± 2 | ± 0.05 | ± 0.2 | 1.0 | ± 1 |
100 Ω | ± 2 | ± 0.05 | ± 0.2 | 1.0 | ± 1 |
1 kΩ | ± 2 | ± 0.05 | ± 0.2 | 1.0 | ± 1 |
Note: TH0330 is an air-type standard resistor, with two of each specification |
DC standard resistance measurement | ||||
Standard resistors ( Z ) |
Resolution ( Z ) |
Test the current ( A ) |
Test the power ( mW ) |
Measurement uncertainty (k=2) ( ppm ) |
1 | 10 n | 100 m | 10 | 0.2 |
10 | 100 n | 31.6 m | 10 | 0.2 |
100 | 1 m | 10 m | 10 | 0.5 |
1 k | 10 m | 3.16 m | 10 | 0.5 |
10 k | 100 m | 1 m | 10 | 2 |
100 k | 1 m | 0.1 m | 1 | 3 |
Note: Current ratio range: 1:1~100:1, ratio uncertainty: 0.15 ppm |
Voltage ratio uncertainty ( k= 2 ) ( ppm ) | |||||
U1 range U2 range |
1 mV | 10 mV | 100 mV | 1 V | 10 V |
1 mV | 5 ( 0.5 ≤ K ≤ 2 ) 10 (0.1 ≤ K < 0.5or2 < K < 10) |
40 ( 1 < K ≤ 2 ) 80 ( 2 < K< 10) |
-- | -- | -- |
10 mV | 40 ( 1 < K ≤ 2 ) 80 ( 2 < K < 10) |
3 ( 0.5 ≤ K ≤ 2 ) 8 (0.1 ≤ K < 0.5or2 < K < 10) |
10 ( 1 < K ≤ 2 ) 30 ( 2 < K < 10) |
-- | -- |
100 mV | -- | 10 ( 1 < K ≤ 2 ) 30 ( 2 < K < 10) |
1 ( 0.5 ≤ K ≤ 2 ) 4 (0.1 ≤ K < 0.5or2 < K < 10) |
3 ( 1 < K ≤ 2 ) 8 ( 2 < K < 10) |
-- |
1 V | -- | -- | 3 ( 1 < K ≤ 2 ) 8 ( 2 < K < 10) |
0.5 ( 0.5 ≤ K ≤ 2 ) 2 (0.1 ≤ K < 0.5or2 < K < 10) |
1.5 ( 1 < K ≤ 2 ) 4 ( 2 < K < 10) |
10 V | -- | -- | -- | 1.5 ( 1 < K ≤ 2 ) 4 ( 2 < K < 10) |
0.5 ( 0.5 ≤ K ≤ 2 ) 2 (0.1 ≤ K < 0.5or2 < K < 10) |
specification | Four-terminal channel |
Connection type | Copper tellurium terminal posts |
Input channel | 10 channels (rear panel) |
Output channel | Single channel (rear panel) |
Thermal electromotive force | < 50 nV |
Maximum carry / switch current | 2 A @ 30 V(DC) |
Contact resistance | < 0.05 h |
Communication interface | RS232 |
The value of the resistance to be measured | Proportion | Maximum current | Measurement uncertainty ( k=2 ). |
100 mΩ | 10:1 | 1 A | 0.2 ppm |
10 mΩ | 100:1 | 10 A | 0.3 ppm |
1 mΩ | 1000:1 | 100 A | 0.4 ppm |
100 mΩ | 10000:1 | 1 kA | 2 ppm |
10 mΩ | 100000:1 | 3 kA | 3 ppm |
1 mΩ | 100000 0:1 | 5 kA | 5 ppm |
0.1 mΩ | 100000 0:1 | 10 kA | 10 ppm |
Electricity type |
Range | Resolution | Measurement uncertainty (k=2) ppm*RD+ppm*RG |
Temperature coefficient ppm*RG/°C |
||
24 hours | 90 days | 1 year | ||||
voltage measurement |
100 mV | 100nV | 10 + 5 | 15 + 5 | 20 + 10 | <0.5 |
1 V | 1 μV | 10 + 5 | 15 + 5 | 20 + 10 | <0.5 | |
10 V | 10 μV | 10 + 5 | 15 + 5 | 20 + 10 | <0.5 | |
current measurement |
10 mA | 10 nA | 10 + 5 | 15 + 5 | 20 + 10 | <0.7 |
100 mA | 100 nA | 10 + 5 | 15 + 5 | 20 + 10 | <0.7 | |
1 A | 1μA | 10 + 5 | 15 + 5 | 20 + 10 | <0.7 |
The entire system occupies a single area | 5700 mm×1850 mm(L×W) |
Single cabinet size | 560 mm×560 mm×1500 mm(W×L×H) |
Laboratory size is recommended | 66 00mm×3000 mm(L×W) |
S/N | Device Name | Type of Power Supply | Maximum Power Consumption | Quantity | Total Power Consumption |
1 | 600 A bipolar high current source module | Three-phase four-wire system AC 380V |
4 kW | 18 units | 72kW |
2 | TK1230 sensor output signal tester | 0.1 kW | 1 set | 0.1 kW | |
3 | Sensor power supply and power consumption test module | 0.1 kW | 1 set | 0.1 kW | |
4 | High current source main control system | 2 kW | 1 set | 2 kW | |
5 | TH1860 bipolar superstable constant current source | Single-phase AC 220V | 0.2 kW | 1 unit | 0.2 kW |
6 | TH0740A standard resistance measuring device | Single-phase AC 220V | 0.1kwatts | 1 set | 0.1 kW |
7 | TH0770 standard resistance multiplexer | Single-phase AC 220V | 0.1kwatts | 1 set | 0.1 kW |
8 | TH0780 ultra-precision current ratio extender | Single-phase AC 220V | 0.1kwatts | 1 set | 0.1 kW |
9 | Computers and printers | Single-phase AC 220V | 0.5 kW | 1 set | 0.5 kwatts |
Total power consumption for the entire system | Approx 75 kW |