TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator

Tunkia Co., Ltd.
  • Audited Supplier
  • 6 yrs

Contact Supplier

Product Highlights

  • High Precision Accuracy: Voltage and current accuracy reaches class 0.05 for professional calibration.
  • Comprehensive Sensor Support: Calibrates 6 types of RTD and 8 types of thermocouples with cold junction compensation.
  • Multi-Function Capability: Handles DC voltage, current, resistance, pulse signals, and thermal resistance simulation.
  • Portable Handheld Design: Compact size 120x60x220mm and lightweight 0.5kg for easy field operation.
  • Long-Term Warranty: Includes 12 months warranty with lifetime excellent after-sales service.
  • OEM/ODM Services: Manufacturer offers OEM and ODM customization services with 120 R&D engineers.
  • Flexible Payment Options: Accepts LC, T/T, D/P, PayPal, and Western Union for international trade.

Product Images of TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator

TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator pictures & photos
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator pictures & photos
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator pictures & photos
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator pictures & photos
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator pictures & photos
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator pictures & photos
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
  • TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
    TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
  • TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
    TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
  • TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
    TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
  • TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
    TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
  • TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
    TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
  • TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
    TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator

Find Similar Products

Product Description

TD7500 Process Signal Calibrator

TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator

 

Summary

 

TD7500 is a handheld thermal instrument and process signal measurement calibration instrument, with an accuracy of class 0.05, which can calibrate class 0.1 and below industrial sensors, transmitters, recorders and other thermal process instruments. TD7500 can calibrate thermal engineering secondary instruments,secondary signals of sensors, transmitters, and thermocouples, secondary instruments for RTD, secondary signals of RTD, pulse measuring instruments, process pulse signals.
 
Features

DC voltage output/measurement: 10 mV~11 V;
DC current output/measurement: 0.2 mA~24 mA
DC resistance simulation: 4 Ω~4.8 kΩ;
 DC resistance measurement (2-wire/4-wire): 4 Ω~4.4 KΩ;
Simulation and measurement of 6 types of thermal resistance (RTD) and 8 types of thermocouples (TC).
Auxiliary power: 24 V Loop mode power.
Voltage/current accuracy: 0.05 level

Application

 

TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator

 
Specifications

4.1 DC Power Output/Measurement

Electricity Range Resolution Measurement Uncertainty (k=2).
( ppm*RD+μV/μA)[1]
Maximum Load
Voltage/Current
Input Resistance
Voltage 100 mV 10 μV 200 + 25 μV 8 mA 1 MΩ
1 V 100 μV 200 + 250 μV 8 mA 1 MΩ
10 V 1 mV 200 + 2000 μV 8 mA 1 MΩ
Current 20mA 1 μA 200 +4 μA 12 V <15Ω
Note [1]: RD is the reading value, the same below.
  1. Voltage output/measurement range: 10 mV~11 V
  2. Current output/measurement range: 0.2 mA~24 mA
 

4.2 DC Resistance Output/Measurement

Type Range Resolution Measurement Uncertainty (k=2).
 ( ppm*RD+Z)
Input Current/Excitation Current
Output 400 Ω 10 mΩ 50 + 0.1 Ω 1 mA~10 mA
4000 Ω 0.1 Ω 50 + 1 Ω 100 μA~1 mA
Measurement 4000 Ω 0.1 Ω 1 H 0.2 mA
  1. Resistance Output Range: 4 Ω~4.8 kΩ
  2.  Resistance Measurement Range: 4 Ω~4.4 kΩ
  3. Resistance Measurement Method: two-wire or four-wire
 

4.3 Pulse signal output/measurement

Regulation/Measurement Range Resolution Measurement Uncertainty (k=2).
1 Hz~1000 Hz 1Hz 0.05%
1 kHz~10 kHz 0.1kHz 0.05%
1.0 CPM~2000.0 CPM 1CPM 0.05%
  1. Output Waveform Signal: square wave signal 5 Vpk
  2. Input Waveform Signal: square wave signal> 1 Vpk

4.4 RTD output/measurement

Type Resistance Range
( Oh)
Temperature Range
(°C)
Measurement Uncertainty (k=2, ±°C) Annual Output Uncertainty
(k=2, ±°C )
Four-wire Two/three-wire
PT100 18.5~391 -200~+850 0.35 0.5 0.35
PT200 37~782 -200~+250 0.2 0.3 0.2
+250~+850 1.0 1.5 1.0
PT500 92~1955 -200~+120 0.2 0.3 0.2
+120~+850 0.4 0.8 0.4
PT1000 185~3910 -200~+100 0.2 0.4 0.2
+100~+850 0.3 0.5 0.3
CU50 39.2~82.2 -50~+150 0.5 0.8 0.5
CU100 78~165 -50~+150 0.25 0.5 0.25
  1. Cold Junction Temperature Compensation: range: -25°C~+55°C; Resolution: 0.1°C; Measurement uncertainty: 0.3°C
  2. Display Digits: 5 digits decimal, can be displayed and output by Ω, °C, °F
 

4.5 Thermocouple Output/Measurement TC

Type Name Voltage Range ( mV ) Temperature Range(°C) Measurement Uncertainty
(k=2, ±°C )
S Platinum rhodium 10-platinum rhodium -0.3~18.7 -50~0 2.0
0~+1750 2.4
R Platinum rhodium 13-platinum -0.3~21.1 -50~0 1.9
0~+1750 2.4
B Platinum rhodium 30-platinum rhodium 6 0.77~13.9 400~+800 2.1
800~+1800 1.8
K Nichrome - Ni-Si -5.9~54.9 -200~0 0.9
0~+1370 1.2
N Nichrome silicon - nickel silicon -4.02~47.6 -200~0 1.4
0~+1750 1.0
And Nickel-chromium-copper-nickel -8.85~76.4 -200~0 0.8
0~+1000 0.9
J Iron-copper-nickel -7.93~69.6 -200~0 0.9
0~+1200 0.7
T Copper-copper-nickel -5.65~20.9 -200~0 1.1
0~+400 0.9
  1. Display Digits: 5 digits decimal, can be displayed and output by Ω, °C, °F
 

5. General Specifications

Power Supply 4 x 1.5V AA batteries;
Maximum Power Consumption 10 VA
Temperature Performance Working temperature: -20°C~50°C; Storage temperature: -20 °C ~ 70 °C
Humidity Performance Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C
Storage humidity: (20%~80%) R· H, no condensation
Altitude < 3000 m
Quality Approx 0.5 kg
Size 120 mm(W) ×60 mm(D) × 220 mm(H)
Company Profile
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator
TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator

TUNKIA Calibration Methods Standard Calibration Multifunction Process Calibrator

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI2191183". Items marked "verified" are certified.

Watch Video
Watch Video
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory
Address
No. 16 Panpan Road, Changsha, Hunan, China
verified Plant Area
8000 square meters
verified Number of Employees
363
verified Registered Capital
25,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Changsha Port

Our Production Capability & Technical Expertise

verified Main Products
Magnetic Measurement, Electrical Measurement, Gaussmeter, Multifunction Calibrator
verified Production Machines
SMT Machine, Printing Machine, Assembly & Debugging Line, Automatic Online Function Test (EPS&SST)
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
120 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-06-16
Export Year
2021-10-11
verified Main Markets
Europe, Southeast Asia/ Mideast, East Asia(Japan/ South Korea), Domestic
verified Number of Foreign Trading Staff
2
verified Overseas Agent/Branch
No

FAQ

What is the accuracy level of the TD7500?
The TD7500 features a voltage/current accuracy of class 0.05, suitable for calibrating class 0.1 and below instruments.
Which types of thermocouples and RTDs are supported?
It supports 6 types of thermal resistance (RTD) including PT100 and 8 types of thermocouples (TC) including S, R, B, K, N, J, T.
What is the warranty period for this device?
The product comes with a 12-month warranty and lifetime excellent after-sales service.
Can this device be customized?
The standard product is non-customized, but the manufacturer offers OEM and ODM services for specific needs.
What are the power supply requirements?
The device is powered by 4 x 1.5V AA batteries with a maximum power consumption of 10 VA.
What are the accepted payment terms?
We accept LC, T/T, D/P, PayPal, and Western Union for payment.
What is the lead time for orders?
The average lead time is one month for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now