• TA2100 Wideband Power Calibrator
  • TA2100 Wideband Power Calibrator
  • TA2100 Wideband Power Calibrator
  • TA2100 Wideband Power Calibrator
  • TA2100 Wideband Power Calibrator
  • TA2100 Wideband Power Calibrator

TA2100 Wideband Power Calibrator

After-sales Service: Life Time
Warranty: 12 Months Excellent After-Sales Service
Power: Electricity
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TA2100 Wideband Power Calibrator pictures & photos
TA2100 Wideband Power Calibrator
US $77,500-79,600 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TA2100
Voltage Output
0.3V~1020V
Current Output
0.5mA~20.5A
LCD Display
With LCD Display
Customized
Non-Customized
Standard Source of Auxiliary Voltage
2.5 mV ~ 5.5 V
Frequency
5 Hz ~ 100 kHz
Power Accuracy
Class 0.05
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
50.00cm * 66.00cm * 27.00cm
Package Gross Weight
25.000kg

Product Description

TA2100 wide frequency power calibrator 

1. Summary

TA2100 Is a wide range, high precision, high stability broadband power calibrator, the instrument can output DC voltage, current and power, and has a dual voltage output mode, suitable for calibration power analyzer, AC / DC power meter, voltmeter, ammeter and other electrical measuring instruments.
 

2. Product features

  1. Standard Source of AC / DC Voltage: 0.3 V ~ 1020 V
  2. Standard Source of AC / DC Current: 0.5 mA ~ 20.5 A
  3. Standard Source of Auxiliary Voltage: 2.5 mV ~ 5.5 V
  4. Sine Wave Frequency: 5 Hz ~ 100 kHz
  5. Power Accuracy: Class 0.05
  6. Phase-Shifted Output
  7. Wideband Power Output
  8. A variety of quantity and value output mode
  9. Cross-guide amplifier (optional)

3. Main applications

☆ Calibration power analyzer (medium to low precision)
TA2100 Wideband Power Calibrator
  1. The accuracy is Class 0.05, using the standard source method to calibrate the medium and low precision (Class 0.2 and below) power analyzer.
  2. The direct output of the maximum 20.5A, can output an current of 50A or 100A.
 
☆ Calibration power analyzer (medium to high precision)
TA2100 Wideband Power Calibrator
  1. TA2100 matches TA3100 wide frequency power measurement standard with accuracy of 0.015%.
  2. Use the standard meter method to calibrate the power analyzer with medium and high precision (Class0.05 and below).

4. Main technical specifications

4.1 AC / DC Voltage Output

Range Resolving Power Voltage Output Range Output Frequency Range Maximum Load Current
3 V 10 μV 0.30000 V ~ 3.30000 V DC, 5 Hz ~ 100 kHz 50 mA
10 V 100 μV 1.0000 V ~ 11.0000 V DC, 5 Hz ~ 100 kHz 50 mA
30 V 100 μV 3.0000 V ~ 33.0000 V DC, 5 Hz ~ 100 kHz 50 mA
100 V 1 mV 10.000 V ~ 110.000 V DC, 45 Hz ~ 100 kHz 50 mA
300 V 1 mV 30.000 V ~ 330.000 V DC, 45 Hz ~ 100 kHz 50 mA
600 V 1 mV 60.000 V ~ 660.000 V DC, 45 Hz ~ 100 kHz 20 mA
1000 V 10 mV 100.00 V ~ 1020.00 V DC, 45 Hz ~ 10 kHz 20 mA
 
Range Measurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (ppm * reading + ppm * range)
DC 5~45 45~1k 1k~10k 10k~20k 20k~50k 50k~100k
3 V 120+80 300+200 120+80 300+200 500+300 600+400 1000+500
10 V 120+80 300+200 120+80 300+200 500+300 600+400 1000+500
30 V 120+80 300+200 120+80 300+200 500+300 600+400 1000+500
100 V 120+80 - 120+80 300+200 500+300 600+400 1000+500
300 V 120+80 - 120+80 300+200 500+300 600+400 1000+500
600 V 120+80 - 120+80 300+200 500+300 600+400 1000+500
1000 V 120+80 - 120+80 300+200 - - -
  1. Range switching: manual or automatic shift
  2. Protection function: short-circuit protection, overload protection, overheat protection
 

4.2 AC / DC Current Output

Range Resolving Power Current Output Range Output Frequency Range Maximum Load Voltage
5 mA 10 nA 0.50000 mA ~ 5.50000 mA DC, 5 Hz ~ 100 kHz 7 V
10 mA 100 nA 1.0000 mA ~ 11.0000 mA DC, 5 Hz ~ 100 kHz 7 V
25 mA 100 nA 2.5000 mA ~ 27.5000 mA DC, 5 Hz ~ 100 kHz 7 V
50 mA 100 nA 5.0000 mA ~ 55.0000 mA DC, 5 Hz ~ 100 kHz 7 V
100 mA 1 μA 10.000 mA ~ 110.000 mA DC, 5 Hz ~ 100 kHz 7 V
200 mA 1 μA 20.000 mA ~ 220.000 mA DC, 5 Hz ~ 100 kHz 6 V
500 mA 1 μA 50.000 mA ~ 550.000 mA DC, 5 Hz ~ 100 kHz 6 V
1 A 10 μA 0.10000 A ~ 1.10000 A DC, 5 Hz ~ 100 kHz 6 V
2.5 A 10 μA 0.25000 A ~ 2.75000 A DC, 5 Hz ~ 100 kHz 6 V
5 A 10 μA 0.50000 A ~ 11.0000 A DC, 5 Hz ~ 100 kHz 6 V
10 A 100 μA 1.0000 A ~ 11.0000 A DC, 5 Hz ~ 100 kHz 6 V
20 A 100 μA 2.0000 A ~ 20.5000 A DC, 5 Hz ~ 100 kHz 6 V
 
Range Measurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (ppm * reading + ppm * range)
DC 5~45 45~1k 1k~10k 10k~20k 20k~50k 50k~100k
5 mA 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
10 mA 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
25 mA 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
50 mA 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
100 mA 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
200 mA 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
500 mA 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
1 A 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
2.5 A 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
5 A 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
10 A 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
20 A 120+80 300+200 120+80 300+200 600+400 1000+500 2k + 1k
  1. Range switch: manual or automatic shift; open circuit protection, overload protection, overheating protection

4.3 Auxiliary Voltage Output

Range Resolving Power Voltage Output Range Output Frequency Range Maximum Load Current
25 mV 100 nV 2.5000 mV ~ 27.5000 mV DC, 5 Hz ~ 100 kHz 10 mA
50 mV 100 nV 5.0000 mV ~ 55.0000 mV DC, 5 Hz ~ 100 kHz 10 mA
100 mV 1 μV 10.000 mV ~ 110.000 mV DC, 5 Hz ~ 100 kHz 10 mA
250 mV 1 μV 25.000 mV ~ 275.000 mV DC, 5 Hz ~ 100 kHz 10 mA
500 mV 1 μV 50.000 mV ~ 550.000 mV DC, 5 Hz ~ 100 kHz 10 mA
1 V 10 μV 0.10000 V ~ 1.10000 V DC, 5 Hz ~ 100 kHz 10 mA
2.5 V 10 μV 0.25000 V ~ 2.75000 V DC, 5 Hz ~ 100 kHz 10 mA
5 V 10 μV 0.50000 V ~ 5.50000 V DC, 5 Hz ~ 100 kHz 10 mA
 
Range Measurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (ppm * reading + ppm * range)
DC 5~45 45~1k 1k~10k 10k~20k 20k~50k 50k~100k
25 mV 150+200 350+250 150+200 350+250 600+400 1000+500 1200+800
50 mV 150+200 350+250 150+200 350+250 600+400 1000+500 1200+800
100 mV 150+200 350+250 150+200 350+250 600+400 1000+500 1200+800
250 mV 150+200 350+250 150+200 350+250 600+400 1000+500 1200+800
500 mV 120+80 300+200 120+80 300+200 500+300 600+400 1000+500
1 V 120+80 300+200 120+80 300+200 500+300 600+400 1000+500
2.5 V 120+80 300+200 120+80 300+200 500+300 600+400 1000+500
5 V 120+80 300+200 120+80 300+200 500+300 600+400 1000+500
  1. Range switching: manual or automatic shift
  2. Wiring mode: BNC plug
  3. Protection function: short-circuit protection, overload protection, overheat protection
  4. Note: This output is especially suitable for the sensor small signal input of the power analyzer
 

4.4 Frequency

Adjustable range Resolving Power Annual Measurement Uncertainty (k=2) @ (23°C ± 5°C)
5.000 0 Hz ≤ F ≤ 99.999 9 Hz 0.000 1 Hz 0.01%
100.000 Hz ≤ F ≤ 999.999 Hz 0.001 Hz 0.01%
1.000 00 kHz ≤ F ≤ 9.999 99 kHz 0.01 Hz 0.01%
10.000 0 kHz ≤ F ≤ 99.999 9 kHz 0.1 Hz 0.01%
100.000 kHz 1 Hz 0.01%
 

4.5 Phase

Phase Position[1][2] Annual Measurement Uncertainty (k=2) @ (23°C ± 5°C)
5~45Hz 45~1kHz 1k~10kHz 10k~20kHz 20k~50kHz 50k~100kHz
φU -I 0.05° 0.02° 0.05° 0.1° 0.2° 0.5°
φU -AUX 0.05° 0.02° 0.05° 0.1° 0.2° 0.5°
Note [1]: Adjustment range: 0.000° ~ 359.999°
Note [2]: Resolution: 0.001°
Phase Position
(φ )
Power Factor
(λ )
The Active Power Uncertainty Component caused by the Phase Uncertainty[3]
5~45Hz 45~1kHz 1k~10kHz 10k~20kHz 20k~50kHz 50k~100kHz
1.00000 0.000% 0.000% 0.000% 0.000% 0.001% 0.004%
10° 0.98481 0.015% 0.006% 0.015% 0.031% 0.062% 0.158%
20° 0.93969 0.032% 0.013% 0.032% 0.064% 0.128% 0.321%
30° 0.86603 0.050% 0.020% 0.050% 0.101% 0.202% 0.508%
40° 0.76604 0.073% 0.029% 0.073% 0.147% 0.294% 0.736%
50° 0.64279 0.104% 0.042% 0.104% 0.208% 0.417% 1.044%
60° 0.50000 0.151% 0.060% 0.151% 0.302% 0.605% 1.515%
70° 0.34202 0.240% 0.096% 0.240% 0.480% 0.960% 2.401%
80° 0.17365 0.495% 0.198% 0.495% 0.990% 1.980% 4.953%
90° 0.00000 - - - - - -
Note [3]: Calculation formula:
TA2100 Wideband Power Calibrator
 

4.6  AC / DC Power Output

Quantity Range Combination Measurement Uncertainty at different frequencies (Hz) (k=2) @ (23°C ± 5°C), (% * power output)[1]
DC 5~45 45~1k 1k~10k 10k~20k 20k~50k 50k~100k
Voltage and Current Output (U & I) @ (λ =1)
(3 V … 30 V) &
(5 mA … 20 A)
0.03 0.07 0.03 0.07 0.13 0.18 0.34
(100 V … 600 V) &
(5 mA … 20 A)
0.03 - 0.03 0.07 0.13 0.18 0.34
1000 V &
(5 mA … 20 A)
0.03 - 0.03 0.07 - - -
Dual Voltage Output (U & AUX) @ (λ =1)
(3 V … 30 V) &
(25 mV … 250 mV)
0.04 0.08 0.04 0.08 0.13 0.18 0.25
(3 V … 30 V) &
(500 mV … 5 V)
0.03 0.07 0.03 0.07 0.13 0.18 0.25
(100 V … 600 V) &
(25 mV … 250 mV)
0.04 - 0.04 0.08 0.13 0.18 0.25
(100 V … 600 V) &
(500 mV … 5 V)
0.03 - 0.03 0.07 0.13 0.18 0.25
1000 V &
(25 mV … 250 mV)
0.04 - 0.04 0.08 - - -
1000 V &
(500 mV … 5 V)
0.03 - 0.03 0.07 - - -
Note [1]: AC / DC power output range (virtual load): 0.15 mW ~ 20.91 kW
 Note [2]: Power factor adjustment range: -1 ~ 0 ~ + 1, resolution: 0.000 01
Note [3]: Power uncertainty calculation formula under other power factors: voltage and current output mode, dual voltage output mode, which: the voltage measurement uncertainty, the current measurement uncertainty, the auxiliary voltage measurement uncertainty, and the measurement uncertainty caused by the power factor.

 

5. General Technical Specifications

Power Supply Voltage AC (220±22) V ,(50±2) Hz
Preheating Time 2 times from the last preheating time, up to 30 minutes.
Temperature Performance Operating temperature: 0°C~40°C
Calibration temperature: 18°C~28°C
Storage temperature: -20°C~70°C
Humidity Performance Working Humidity: <80% @ 30°C, <70% @ 40°C
Storage humidity: (20%~80%) R · H, no condensation
Above Sea Class <3000 m
Communication Interface RS232×1,USB×1,LAN×1

Company Profile
 

TA2100 Wideband Power Calibrator

TA2100 Wideband Power CalibratorTA2100 Wideband Power Calibrator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TA2100 Wideband Power Calibrator pictures & photos
TA2100 Wideband Power Calibrator
US $77,500-79,600 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013