• TD4100 Testing System for Three-phase and DC Meters
  • TD4100 Testing System for Three-phase and DC Meters
  • TD4100 Testing System for Three-phase and DC Meters
  • TD4100 Testing System for Three-phase and DC Meters
  • TD4100 Testing System for Three-phase and DC Meters
  • TD4100 Testing System for Three-phase and DC Meters

TD4100 Testing System for Three-phase and DC Meters

After-sales Service: Life Time
Warranty: 12 Month After Sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD4100 Testing System for Three-phase and DC Meters pictures & photos
TD4100 Testing System for Three-phase and DC Meters
US $26,300-29,700 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD4100
Power
Electricity
LCD Display
With LCD Display
Customized
Non-Customized
3PH AC voltage output
1 V~825 V
3PH AC current output
2 mA~110 A
Frequency
45 Hz~70 Hz
DC voltage output
5 mV~1100 V
Accuracy class
0.02, 0.05
Transport Package
Package for Exporting
Specification
35.5kg; 560 mm(W)x530 mm(D) x 200 mm(H)
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
65.00cm * 40.00cm * 25.00cm
Package Gross Weight
42.000kg

Product Description

TD4100 Testing System for Three-phase and DC MetersTD4100 Testing System for Three-phase and DC Meters

1. Summary

TD4100 is a multifunctional 3PH power source. It integrates AC/DC power output function, harmonic function, transmitter test function, AC energy meter test function. Can be used to calibrate AC/DC voltmeter, AC/DC ammeter, AC/DC power meter, electric energy meter and transmitter, etc.
 

2. Features

  1. 3PH AC voltage output:1 V~825 V
  2. 3PH AC current output:2 mA~110 A
  3. Frequency:45 Hz~70 Hz
  4. U-I phase:~360°
  5. DC voltage output:5 mV~1100 V
  6. DC current output:1 μA~33 A
  7. Accuracy class: 0.02, 0.05.
  8. 2nd~21st harmonic output (option)
  9. Transmitter test function (option)
  10. AC energy meter test function(option)
  11. Test software(option)

3. Application

TD4100 Testing System for Three-phase and DC Meters

 

4. Characteristics

Wide Output
TD4100 Testing System for Three-phase and DC Meters
  1. It can meet most single-phase / three-phase meters or DC meters.



 
Multiple Output Mode
TD4100 Testing System for Three-phase and DC Meters
  1. "Direct output"mode,User can set output value by physical key or touch screen.
  2. Three-phase unit adjustment or single phase adjustment.
TD4100 Testing System for Three-phase and DC Meters
  1. "Remote Control Box(option)",by operation of coarse tuning-fine tuning,can calibrate analog meter.


 
Multiple Output Mode
TD4100 Testing System for Three-phase and DC Meters
  1. Touch "Calibration point"of screen for "% setting".
TD4100 Testing System for Three-phase and DC Meters
  1. "Rotary Knob"mode,User can setting in clockwise direction or anticlockwise direction.


 

Harmonics Function
TD4100 Testing System for Three-phase and DC Meters
S/N Function declaration
1 Set amplitude of harmonic.
2 Set phase of harmonic(fundamental wave).
3 Choose 2nd~21st harmonics channel output.
4 Oscilloscope function, user can observe voltage and current waves.
5 Display frequency spectrum of harmonic by histogram.(fundament wave is 100%)
 

5. Specifications

5.1 Three-Phase Voltage Output

Voltage Range Resolution Stability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (mA)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
15 V 0.1 mV 0.01 0.005 300 + 200 120 + 80 500
57.7 V 0.1 mV 0.01 0.005 300 + 200 120 + 80 500
100 V 1 mV 0.01 0.005 300 + 200 120 + 80 300
220 V 1 mV 0.01 0.005 300 + 200 120 + 80 140
380 V 1 mV 0.01 0.005 300 + 200 120 + 80 80
600 V 1 mV 0.01 0.005 300 + 200 120 + 80 50
750 V 10 mV 0.01 0.005 300 + 200 120 + 80 30
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%).
  1. Three-phase voltage output:1 V~825 V;
  2. Degree of distortion:<0.2%
  3. Short circuit and overload protection
 

5.2 Three-Phase Current Output

Current Range Resolution Stability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (V)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
20 mA 0.1 μA 0.01 0.005 300 + 200 120 + 80 60
50 mA 0.1 μA 0.01 0.005 300 + 200 120 + 80 60
100 mA 1 μA 0.01 0.005 300 + 200 120 + 80 60
200 mA 1 μA 0.01 0.005 300 + 200 120 + 80 30
500 mA 1 μA 0.01 0.005 300 + 200 120 + 80 30
1 A 10 μA 0.01 0.005 300 + 200 120 + 80 30
2 A 10 μA 0.01 0.005 300 + 200 120 + 80 6
5 A 10 μA 0.01 0.005 300 + 200 120 + 80 6
10 A 100 μA 0.01 0.005 300 + 200 120 + 80 2.5
20 A 100 μA 0.01 0.005 300 + 200 120 + 80 1.2
50 A 100 μA 0.01 0.005 300 + 200 120 + 80 0.8
100 A 1 mA 0.01 0.005 300 + 200 120 + 80 0.8
  1. Three-phase current output:2 mA~110 A;
  2. Degree of distortion:<0.2%
  3. Current open-circuit and overload protection
 

5.3 Frequency / Phase / Harmonic

Symmetry Voltage superior to 0.2%;Current superior to 0.5%;Phase superior to 0.5°
Frequency Range:45 Hz~70 Hz;Adjustment fineness:0.001 Hz;
Accuracy:±0.02 Hz (class 0.05), ±0.01 Hz(class 0.02)
Phase Range:0.000 0°~359.999 9°;Adjustment fineness:0.001°;
Accuracy:±0.02° (class 0.05), ±0.01°(class 0.02)
Harmonic(optional) 2nd~21st harmonic;
Amplitude 0~25% adjustable;Phase 0~359.99°adjustable
 

5.4 Three-Phase Power Output

Current Range Stability
( %/min )
Accuracy
( ± %*FS)[2]
Class 0.05 Class 0.02 Class 0.05 Class 0.02
Active power |cosφ|≥0.5 0.01 0.005 0.05 0.02
Reactive power |sinφ|≥0.5 0.02 0.01 0.1 0.05
Apparent power 0.02 0.01 0.1 0.05
Power factor 0.02 0.01 0.1 0.05
Note [2] :FS= voltage range ×current range
  1. Power factor range:-1.000 000…0.000 000…1.000 000
 

5.5 DC Voltage Output

Voltage Range Resolution Stability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (mA)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
75 mV 0.1 μV 0.01 0.005 300 + 200 120 + 120 10
100 mV 1 μV 0.01 0.005 300 + 200 120 + 80 10
300 mV 1 μV 0.005 0.005 300 + 200 120 + 80 10
1 V 10 μV 0.005 0.005 300 + 200 120 + 80 10
3 V 10 μV 0.005 0.005 300 + 200 120 + 80 10
10 V 100 μV 0.005 0.005 300 + 200 120 + 80 10
30 V 100 μV 0.005 0.005 300 + 200 120 + 80 500
60 V 100 μV 0.005 0.005 300 + 200 120 + 80 150
100 V 1 mV 0.005 0.005 300 + 200 120 + 80 150
300 V 1 mV 0.005 0.005 300 + 200 120 + 80 50
600 V 1 mV 0.005 0.005 300 + 200 120 + 80 25
1000 V 10 mV 0.005 0.005 300 + 200 120 + 80 15
  1. DC voltage output range:5 mV~1100 V,
  2. Ripple factor:< 1%
  3. Short circuit and overload protection
 

5.6 DC Current Output

Current Range Resolution Stability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (V)
Class 0.05 Class 0.02 Class 0.05 Class 0.02
10 μA 0.1 nA 0.01 0.005 300 + 200 120 + 80 10
30 μA 0.1 nA 0.01 0.005 300 + 200 120 + 80 10
100 μA 1 nA 0.01 0.005 300 + 200 120 + 80 10
300 μA 1 nA 0.01 0.005 300 + 200 120 + 80 10
1 mA 10 nA 0.01 0.005 300 + 200 120 + 80 10
3 mA 10 nA 0.01 0.005 300 + 200 120 + 80 10
10 mA 100 nA 0.01 0.005 300 + 200 120 + 80 10
30 mA 100 nA 0.01 0.005 300 + 200 120 + 80 10
100 mA 1 μA 0.01 0.005 300 + 200 120 + 80 10
300 mA 1 μA 0.01 0.005 300 + 200 120 + 80 4
1 A 10 μA 0.01 0.005 300 + 200 120 + 80 4
3 A 10 μA 0.01 0.005 300 + 200 120 + 80 4
10 A 100 μA 0.01 0.005 300 + 200 120 + 80 3
30 A 100 μA 0.01 0.005 300 + 200 120 + 80 2.5
  1. DC current output range:1 μA~33 A,
  2. Ripple factor:< 1%
  3. Current open-circuit and overload protection
 

5.7 DC Meter(option)

Range Measurement Range Accuracy Measurement Range of Ripple Accuracy of Ripple
1 V ± ( 0~1.2 ) V ± 0.01%*range 0~30 mV ± 1 mV
10 V ± ( 0~12 ) V ± 0.01%* range 0~300 mV ± 10 mV
2 mA ±( 0~2.4) mA ± 0.01%* range 0~60 μA ± 2 μA
20 mA ± ( 0~24 ) mA ± 0.01%* range 0~600 μA ± 20 μA
Note:This DC Meter is used to test second signal of Transmitter
 

5.8 AC Energy Testing(option)

Type Accuracy
Class 0.05 Class 0.02
Active electrical energy ± 0.1%*reading ± 0.05%*reading
Reactive electrical energy ± 0.2%*reading ± 0.1%*reading
  1. Energy pulse output:full range for 60 kHz
  2. Energy pulse input:max frequency is 200 kHz,pulse level:3 V~12 V
  3. Constant setting of Electrical energy meter:1…1000000 imp./kwh or 1…1000000 imp./ws

6. General Specifications

Power Supply AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
Temperature Performance Working temperature:0°C~45°C;
Storage temperature:-20°C~70°C
Humidity Performance Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C
Storage humidity:(20%~80%) R·H,actnon-condensing
Interface RS232
 

7. Ordering Information

 TD4100 Testing System for Three-phase and DC Meters
 
Company Profile
 

TD4100 Testing System for Three-phase and DC Meters

TD4100 Testing System for Three-phase and DC MetersTD4100 Testing System for Three-phase and DC Meters

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD4100 Testing System for Three-phase and DC Meters pictures & photos
TD4100 Testing System for Three-phase and DC Meters
US $26,300-29,700 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013