Specification | Nominal input voltage ( KV ) |
Maximum input voltage ( KV ) |
Nominal output voltage ( V ) |
Proportional uncertainty ( k=2, ppm ) |
TH0170-1k | 1 | 1.1 | 10 | 30 |
TH0170-2k | 2 | 2.2 | 10 | 30 |
TH0170-5k | 5 | 5.5 | 10 | 50 |
TH0170-10k | 10 | 11 | 10 | 50 |
TH0170-20k | 20 | 22 | 10 | 50 |
TH0170-50k | 50 | 55 | 10 | 60 |
Specification | Input resistance ( MΩ ) | Output resistance ( kΩ ) | Temperature coefficient ( ppm/K ) | Voltage influence factor ( ppb/V ) |
TH0170-1k | 10 | 100 | 2 | 10 |
TH0170-2k | 20 | 100 | 2 | 5 |
TH0170-5k | 50 | 100 | 2 | 4 |
TH0170-10k | 200 | 200 | 5 | 2 |
TH0170-20k | 400 | 200 | 5 | 1 |
TH0170-50k | 800 | 160 | 5 | 0.5 |
Power supply | -- |
Warm up time | 30 minutes |
Temperature performance | Operating temperature: 5°C ~ 40°C; Storage temperature: -10°C to 55°C Note: When stored in a harsh temperature environment, the resistance value may change temporarily and be restored to the original resistance value within the following 30 days. |
Humidity performance | Working humidity :(30%-70%) R·H, no condensation Storage humidity :(20% ~ 80%) R·H, no condensation |
Connection mode | The input connection adopts high pressure socket, and the output connection adopts a pair of ф 4 mm female socket |
Specification | Size (mm) (W * D * H) (excluding terminals) |
Weight ( kg ) |
Size chart |
TH0170-1k TH0170-2k TH0170-5k TH0170-10k |
180 × 180 × 120 | 2 | |
TH0170-20k | 430 × 320 × 250 | 13.5 | |
TH0170-50k | 430 × 320 × 300 | 16 |