TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 12 Months Excellent After-Sales Service
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013
  • TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
  • TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
  • TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
  • TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
  • TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
  • TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
Find Similar Products

Basic Info.

Model NO.
TH0410
Application
Electromagnetic Instrument, Electrical Calibration
Power
Electricity
Voltage Output
1V
Customized
Customized
Input Current
20mA~10A
Workign Frequency
DC~1MHz
AC DC difference
Less than or equal to 30 ppm@53Hz
Optimum phase shift
5 urad
Nominal output voltage
1V (customizable)
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Product Description

TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device

1. Summary

TH0410 is a set of nine precision AC/DC shunts of different ranges that convert a nominal input current of 20 mA ~ 1 0 A to 1 V Small voltage, easy to access voltage high-speed sampling system or high-precision data meter, to achieve broadband or complex waveform current measurement, or used to calibrate broadband current sources, transformers, sensors, etc.

2. Features
Operating frequency: DC ~ 1 MHz
AC and DC difference: ≤ 30 ppm @53Hz
Optimal phase displacement: 5 μrad
The nominal output voltage is 1 V (other voltage values can be customized).
The typical annual variation is typically 5 ppm and the maximum is 18 ppm.
The 1 mA, 10 mA versions mate buffers to reduce output impedance.
 
3. Applications
☆ Set up a broadband current measurement system
 
 
TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current deviceTH0410 can be used with broadband current source, broadband standard voltmeter (such as TH2000 vector voltage analyzer), etc. to form a broadband current measurement system, which is used to measure broadband current signals, calibrate broadband current sources, broadband ammeters, etc.

☆ Set up broadband power precision measurement system
 
TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current deviceTH0410 can be used with high-frequency V/V conversion standard and TH2000 vector voltage analyzer to form a broadband power/energy precision measurement system for measuring broadband power/ Power signal, calibration of broadband power source, broadband power meter, power analyzer and other equipment.


 
  • Build a broadband instrument transformer / sensor measurement system
TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
 
For the calibration of the transformer or sensor under test with a nominal current of ≤ 10A, TH0410 can be used directly as the standard device, with a broadband constant current source and a broadband sensor tester ( vector voltage analyzer), etc. to form a broadband transformer/sensor measurement system.

  • Build a broadband transformer/sensor calibration system
TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
For calibration of transformers or sensors with nominal currents greater than 10 A, TH0410 is used as a secondary signal I/V converter for standard and tested equipment, with broadband constant current source, Broadband sensor testers (vector voltage analyzers), etc. form broadband transformers/sensor measurement systems.


 
☆ Set up sensor bandwidth calibration system
TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
    
TH0410 can be used with broadband standard voltmeters (such as TH20 0 0 vector voltage analyzer) to form a sensor bandwidth calibration system.



4. Specifications
4.1 Resistance
Specifications Nominal resistance
( Z )
Initial deviation [1].
( ±mH/Z )
@ (23±1)°C
Annual stability
( ±mH/Z )
Temperature coefficient
( ±ppm/K )
Power factor [2].
( ±ppm/rated power ).
TH0410-20mA 50 50 18 2.5 1
TH0410-50mA 20 50 18 2.5 1
TH0410-100mA 10 50 18 2.5 2
TH0410-200mA 5 50 18 2.5 4
TH0410-500mA 2 50 18 2.5 12
TH0410-1A 1 50 18 4.0 25
TH0410-2A 500 m 50 18 4.0 25
TH0410-5A 200 m 50 18 4.0 30
TH0410-10A 100 m 50 18 4.0 60
Note [1]: The initial deviation is the maximum offset of the resistance value under DC conditions, usually the manufacturer's factory warranty; Higher accuracy can be customized according to user requirements, such as 20 μΩ/Ω.
Note [2]: When measuring DCI with a coaxial shunt, the resistance value changes due to the heat generation of the resistor itself at different input currents, resulting in an error.


4.2 Current measurement
Specifications Primary nominal current (A). Secondary nominal
Voltage (V).
AC/DC difference [3] (±ppm). Maximum operating
Current (A).
Instantaneous current
(A, <5 s)
50 Hz 1 kHz 1 MHz
TH0410-20mA 20 m 1 20 25 50 40m 250m
TH0410-50mA 50 m 1 20 25 50 100m 500m
TH0410-100mA 100 m 1 20 25 25 200m 1.5
TH0410-200mA 200 m 1 20 25 25 500m 2
TH0410-500mA 500 m 1 20 25 25 1 3
TH0410-1A 1 1 20 25 30 1.5 4
TH0410-2A 2 1 20 30 50 2.5 6
TH0410-5A 5 1 20 30 80 5.5 20
TH0410-10A 10 1 20 30 100 11 30
Note [3]: The measured value of AC current should be calculated according to the following formula, and the unit of AC and DC difference is ppm:

4.3 Phase displacement
Specifications Phase displacement (±μrad).
53 Hz 400 Hz 1 kHz 10 kHz 50 kHz 100 kHz 1 MHz
TH0410-20mA 5 5 10 100 400 800 800
TH0410-50mA 5 5 10 100 400 800 800
TH0410-100mA 5 5 10 60 300 500 500
TH0410-200mA 5 5 10 60 300 500 500
TH0410-500mA 5 5 10 60 300 500 500
TH0410-1A 5 5 10 60 300 500 500
TH0410-2A 10 10 15 110 500 1000 1000
TH0410-5A 10 15 25 200 1000 2000 2000
TH0410-10A 10 20 40 300 1500 3000 3000
 
5. General Specifications
Power supply --
Temperature performance Working temperature: 13°C~33°C;
Calibration temperature: 18°C~28°C;
Storage temperature: 5 °C ~ 45 °C
Note: When stored in harsh temperature environments, it may cause a temporary change in the resistance value and return to the original resistance value within the next 30 days.
Humidity performance Operating humidity: < 50% R· H
Storage humidity: (15%~80%) R· H, no condensing
altitude < 3000 m
Connection method Input connection: Type-N type female plug;
Output connection: Type-N type female plug.
TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device

Specifications Size( mm ) ( W*D * H )
( without terminal blocks )
Quality
( kg )
Dimensional drawing
TH0410-2 0 mA
TH0410-5 0 mA
TH0410-100mA
65 × 68 × 68 0.1 TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
TH0410-200mA
TH0410-500mA
TH0410-1A
TH0410-2A
82 × 94 × 94 0.2 TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device
TH0410-5A TH0410-10A 154 × 205 × 205 1 TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device



6. Ordering Information
TUNKIA TH0410 high frequency coaxial shunt calibrate broadband current device Model Nominal current
TH0410-20mA 20 mA
TH0410-50mA 50 mA
TH0410-100mA 1,00 mA
TH0410-200mA 200 mA
TH0410-500mA 500 mA
TH0410-1A 1 A
TH0410-2A 2 A
TH0410-5A 5 A
TH0410-10A 10 A
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier