Customization: | Available |
---|---|
After-sales Service: | Life Time |
Warranty: | 12 Months Excellent After-Sales Service |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
|
|
|
☆ Connect V/V to measure high voltage |
|
Measurement type | Current range | Resolution | Measurement uncertainty at different frequencies (k=2, ppm*RD+ppm*RG). | |||
DC | 45 ≤ F≤ 200 | 200 < F ≤ 1k | 1k < F ≤ 5k | |||
Direct measurement | 100 μA | 0.1 nA | 60 +40 | 120 + 80 | 200 + 100 | 300 + 200 |
200 μA | 0.1 nA | 60 +40 | 120 + 80 | 200 + 100 | 300 + 200 | |
500 μA | 0.1 nA | 60 +40 | 120 + 80 | 200 + 100 | 300 + 200 | |
1 mA | 1 nA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
2 mA | 1 nA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
5 mA | 1 nA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
10 mA | 10 nA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
20 mA | 10 nA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
50 mA | 10 nA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
1 00mA | 100 nA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
200 mA | 100 nA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
500 mA | 100 nA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
1 A | 1 μA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
2 A | 1 μA | 30 + 20 | 60 +40 | 100 + 50 | 150 + 50 | |
Sensor measurement (Straight in). |
5 A | 1 μA | 30 + 20 | 200 + 100 | 500 + 100 | 1000 + 100 |
10 A | 10 μA | 30 + 20 | 200 + 100 | 500 + 100 | 1000 + 100 | |
20 A | 10 μA | 30 + 20 | 200 + 100 | 500 + 100 | 1000 + 100 | |
50 A | 10 μA | 30 + 20 | 200 + 100 | 500 + 100 | 1000 + 100 | |
100 A | 100 μA | 30 + 20 | 200 + 100 | 500 + 100 | 1000 + 100 | |
Sensor measurement (Piercing). |
200 A | 100 μA | 30 + 20 | 200 + 100 | 500 + 100 | 1000 + 100 |
500 A | 100 μA | 30 + 20 | 200 + 100 | 500 + 100 | 1000 + 100 | |
1 kA | 1 mA | 30 + 20 | 200 + 100 | 500 + 100 | 1000 + 100 | |
2 kA | 1 mA | 30 + 20 | 200 + 100 | 500 + 100 | 1000 + 100 | |
Note [1]: RD is the reading value and RG is the range value. Note [2]: Current sensors are optional, one sensor per range |
Measurement type | Voltage range | Resolution | Measurement uncertainty at different frequencies (k=2, ppm*RD+ppm*RG). | |||
DC | 45 ≤ F≤ 200 | 200 < F ≤ 1k | 1k < F ≤ 5k | |||
Direct measurement | 1 V | 1 mV | 18 + 12 | 30 + 20 | 60 + 40 | 100 + 50 |
2 V | 1 mV | 18 + 12 | 30 + 20 | 60 + 40 | 100 + 50 | |
5 V | 1 mV | 18 + 12 | 30 + 20 | 60 + 40 | 100 + 50 | |
10 V | 10 mV | 18 + 12 | 30 + 20 | 60 + 40 | 100 + 50 |
Power supply | AC (220±22) V,(50±2) Hz |
Maximum power consumption | 100 VA |
Warm-up time | 2 times the warm-up time from the last forecast, up to 30 minutes |
Working environment | 15°C ~ 35°C, (20%~85%) R· H, no-condensing |
Storage environment | 0°C ~ 40°C, < 95% R· H, no-condensing |
altitude | <3000 m |
Communication interface | USB×1,LAN×1,RS232×1 |
Size | 215 mm (W) × 252 mm (D) ×88 mm(H), without feet |
Quality | Approx 5 kg |