TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 12 Months Excellent After-sales Service
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013
  • TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
  • TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
  • TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
  • TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
  • TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
  • TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD1870
Application
Electromagnetic Instrument, Electrical Calibration
Power
Electricity
Voltage Output
Max. 1020V
Current Output
Max. 20.5A
Thermocouple (TC)
S, R, B, K, N, E, J, T
LCD Display
With LCD Display
Customized
Non-Customized
DC voltage output
±(0 ~ 1020 V)
DC current output
±(0 ~ 20.5 A)
AC voltage output
1mV ~ 1020V
AC current output
29 μA ~ 20.5 A
Sinusoidal wave frequency
10 Hz ~ 500 kHz
Simulated DC resistance
0 Ω ~ 1100 MΩ
Transport Package
Package for Exporting
Specification
444 mm(W)*510 mm (D) * 205 mm (H), 25Kg
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Product Description

TD1870 Multi-function Calibrator TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below

1. Summary

TD1870 is a multi-function calibrator with wide range and high accuracy, integrates AC/DC voltage and current standard source, can output excellent DC\AC voltage, DC\AC current, DC\AC power, phase, frequency, and analog resistance etc. It's applied for calibrating 5.5 digits or less digital multimeters.

2. Features

DC voltage output: ±(0 ~ 1020 V)
DC current output: ±(0 ~ 20.5 A)
AC voltage output: 1 mV ~ 1020 V
AC current output: 29 μA ~ 20.5 A
Sinusoidal wave frequency: 10 Hz ~ 500 kHz
Simulated DC resistance: 0 Ω ~ 1100 MΩ
2 MHz square wave frequency output
Phase output
AC/DC power output
Thermocouple output(optional)
Thermal resistance output(optional)
Clamp meter calibration (optional)   

3. Application

TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below

 
 Calibrate AC\DC electrical measuring instruments  
TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
DCV Output: ±(0 ~ 1020 V)
DCI Output: ±(0 ~ 20.5 A)
ACV Output: 1 mV ~ 1020 V,10 Hz ~ 500 kHz
ACI Output: 29 μA ~ 20.5 A,10 Hz ~ 30 kHz
RES Output: 0 Ω ~ 1100 MΩ
F Output: 1 Hz ~ 2 MHz
Calibrate digital multimeter, AC/DC voltmeter, AC/DC ammeter, DC ohmmeter, frequency meter.

  Calibrate AC\DC power meters
TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
Calibrate DC power meter, real power meter, phantom power meter, apparent power meter, power frequency phase meter and power factor meter.

 Calibrate temperature meters(optional)
TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
Type of thermocouple (TC) output and measurement: B, E, J, K, N, R, S, T(8 types)
Type of thermal resistance ( RTD ) output: PPt385-100Ω,Pt385-200Ω,Pt385-500Ω,Pt385-1000Ω,Cu50,Cu100 (6 types)
 
 Calibrate clamp ammeter (optional)
TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters.

 4. Panel Features
 Front panel
TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
Item Description
1 LCD touchable screen.
2 Operation panel.
3 Pulse frequency output terminal.
4 Simulated DC resistance, RTD, Auxiliary voltage output terminals.
5 Simulated capacitance output terminals.
6 AC/DC voltage output terminals.
7 Thermocouple output terminals.
8 AC/DC current output terminals.


 
Rear\Side Panel
TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
Item Description
1 Handle: used for carrying instruments
2 Foldable feets
3 USB/LAN/RS232
4 AC 220V power interface
5 power switch
6 Chassis ground binding post
7 Cooling vents

5. Characteristic

4-terminals Simulated DC resistance
TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
2-terminals and 4-terminals resistance wiring mode. When calibrating the low value resistance, the four wire system wiring mode can effectively eliminate the measurement error caused by the resistance of the test lead and improve the measurement accuracy.
Compared with the standard physical resistance box, the analog resistance output has the following characteristics:  
a. Continuously adjustable, with better adjustment fineness and sensitivity. 
b. Smaller size and lighter weight. 
c. No influence of transfer switch error, residual resistance error and contact resistance error.    


 
 Multiple output\adjustment methods
TD1870 Multi-function Calibrator for Calibrating 5.5 DMM & Below
"Direct output" mode: the value output can be set directly by physical key or touch screen.
 

6. Specifications

6.1 DC Voltage Output

Range Output Range Accuracy (Tcal±5°C) Stability
(Tcal±1°C)
Resolution Max Burden [Source internal resistance]
±(ppm*output + μV)
90 days 1 year 24 hours
300 mV 0~330.0000 mV 50 + 3 60 + 3 5 + 1 100 nV [60 Ω]
3 V 0~3.300000 V 40 + 5 50 + 5 4 + 3 1 μV 20 mA
30 V 0~33.00000 V 40 + 50 50 + 50 4 + 30 10 μV 15 mA
300 V 30.0000 V~330.0000 V 45 + 500 55 + 500 4.5 + 300 100 μV 10 mA
1000 V 100.000 V~1020.000 V 45 + 1500 55 + 1500 4.5 + 900 1 mV 10 mA
  1. Manual or automatic range switch.
  2. Short-circuit and overload protection.
6.2 DC Current Output
Range Output Range Accuracy(Tcal±5°C)
±(ppm*output + μA)
Resolution Compliance Voltage (V) Max Inductive Load
90 days 1 year
300 μA 0~330.000 μA 112 + 0.02 140 + 0.02 1 nA 11 V 400 μH
3 mA 0~3.30000 mA 72 + 0.04 90 + 0.04 10 nA 11 V
30 mA 0~33.0000 mA 72 + 0.25 90 + 0.25 100 nA 9 V
300 mA 0~330.000 mA 72 + 2.5 90 + 2.5 1 μA 7 V
1 A 0~1.10000 A 200 + 44 250 + 40 10 μA 6 V
3 A 1.00000 A~3.30000 A 240 + 44 300 + 40 10 μA 6 V
20 A 3.0000 A~20.5000 A 480 + 500 600 + 500 100 μA 4 V
  1. Manual or automatic range switch.
  2. Open-circuit and overload protection.
  3. Supports continuous and long-term output of current under full range.
6.3 Simulated DC resistance
Range Output Range Accuracy, (Tcal±5°C)
±(ppm*output + Ω)
Resolution Allowable Current
90 days 1 year
10 Ω 0 Ω~11.00000 Ω 80 + 0.01 100 + 0.01 10 μΩ 1 mA~150 mA
30 Ω 10.00000 Ω~33.00000 Ω 80 + 0.015 100 + 0.015 10 μΩ 1 mA~150 mA
100 Ω 30.0000 Ω~110.0000 Ω 64 + 0.015 80 + 0.015 100 μΩ 1 mA~80 mA
300 Ω 100.0000 Ω~330.0000 Ω 64 + 0.02 80 + 0.02 100 μΩ 1 mA~40 mA
1 kΩ 0.300000 kΩ~1.100000 kΩ 64 + 0.02 80 + 0.02 1 mΩ 1 mA~20 mA
3 kΩ 1.000000 kΩ~3.300000 kΩ 64 + 0.2 80 + 0.2 1 mΩ 0.1 mA~6 mA
10 kΩ 3.00000 kΩ~11.00000 kΩ 64 + 0.1 80 + 0.1 10 mΩ 0.1 mA~2 mA
30 kΩ 10.00000 kΩ~33.00000 kΩ 64 + 1 80 + 1 10 mΩ 10 μA~0.6 mA
100 kΩ 30.0000 kΩ~110.0000 kΩ 80 + 1 100 + 1 100 mΩ 10 μA~0.2 mA
300 kΩ 100.0000 kΩ~330.0000 kΩ 80 + 10 100 + 10 100 mΩ 1 μA~60 μA
1 MΩ 0.300000 MΩ~1.100000 MΩ 104 + 10 130 + 10 1 Ω 1 μA~20 μA
3 MΩ 1.000000 MΩ~3.300000 MΩ 104 + 150 130 + 150 1 Ω 0.25 μA~6 μA
10 MΩ 3.00000 MΩ~11.00000 MΩ 400 + 250 500 + 250 10 Ω 0.25 μA~2 μA
30 MΩ 10.00000 MΩ~33.00000 MΩ 650 + 2500 800 + 2500 10 Ω 25 nA~600 nA
100 MΩ 30.0000 MΩ~110.0000 MΩ 3600 + 3000 4500 + 3000 100 Ω 25 nA~200 nA
300 MΩ 100.0000 MΩ~330.0000 MΩ 3600 + 100000 4500 + 100000 100 Ω 2.5 nA~60 nA
1 GΩ 300.000 MΩ~1100.000 MΩ 11000 + 480000 14000 + 480000 1 kΩ 1 nA~20 nA
  1. Manual or automatic range switch.
  2. Over-current and reverse connection protection.
6.4 AC Voltage Output
Range Output Range  Frequency
(Hz)
Accuracy,(Tcal±5°C)
±(%*output + μV)
Resolution Max Burden [Source internal resistance]
90 days 1 year
30 mV 1.0000 mV~
33.0000 mV
10≤F≤45 0.10 + 20 0.12 + 20 100 nV [10 Ω]
45<F≤10k 0.08 + 20 0.10 +  20
10k<F≤20k 0.12 + 20 0.15 +  20
20k<F≤50k 0.16 + 20 0.20 +  20
50k<F≤100k 0.30 + 33 0.35 + 33
100k<F≤500k 0.72 + 60 0.90 + 60
300 mV 30.000 mV~
330.000 mV
10≤F≤45 0.04 + 18 0.05 + 18 1 μV [60 Ω]
45<F≤10k 0.024 + 18 0.03 + 18
10k<F≤20k 0.048 + 18 0.06 + 18
20k<F≤50k 0.064 + 30 0.08 + 40
50k<F≤100k 0.12 + 120 0.15 + 120
100k<F≤500k 0.28 + 300 0.35 + 300
3 V 0.30000 V~
3.30000 V
10≤F≤45 0.04 + 55 0.05 + 55 10μV 20 mA
45<F≤10k 0.016 + 55 0.02 + 55
10k<F≤20k 0.048 + 55 0.06 + 55
20k<F≤50k 0.064 + 55 0.08 + 55
50k<F≤100k 0.12 + 180 0.15 + 180
100k<F≤500k 0.32 + 800 0.40 + 800
30 V 3.0000 V~
33.0000 V
10≤F≤45 0.04 + 750 0.05 + 750 100 μV 15 mA
45<F≤10k 0.024 + 550 0.03 + 550
10k<F≤20k 0.048 + 550 0.06 + 550
20k<F≤50k 0.064 + 550 0.08 + 550
50k<F≤100k 0.16 + 1800 0.20 + 1800
300 V 30.000 V~
330.000 V
45≤F≤1k 0.024 + 2500 0.03 + 2500 1 mV 30 mA [1]
1k<F≤10k 0.032 + 8000 0.04 + 8000
10k<F≤20k 0.048 + 8000 0.06 + 8000
20k<F≤50k 0.096 + 9000 0.12 + 9000
50k<F≤100k 0.192 + 80000 0.24 + 80000
1000 V 300.00 V~
1020.00 V
45≤F≤1k 0.024 + 15000 0.03 + 15000 10 mV 8 mA [2]
1k<F≤5k 0.032 + 15000 0.04 + 15000
5k<F≤10k 0.032 + 15000 0.04 + 15000
Note: [1] When the output frequency ≤ 3kHz, the maximum load is 30 mA; When the output frequency >3kHz, the maximum load is 5 mA.
[2] When the output frequency ≤ 3kHz, the maximum load is 8 mA; When the output frequency >3kHz, the maximum load is 3 mA.
  1. Manual or automatic range switch.
  2. Short-circuit and overload protection.
6.5 AC Current Output
Range Output Range Frequency
(Hz)
Accuracy(Tcal±5°C)
±(%*output + μA)
Resolution Compliance Voltage (rms) Max Inductive Load
90 days 1 year
300 μA 29.000 μA~
330.000 μA
10≤F≤20 0.128 + 0.1 0.16 + 0.1 1 nA 7 V 200μH
20<F≤45 0.096 + 0.1 0.12 + 0.1
45<F≤1k 0.064 + 0.1 0.08 + 0.1
1k<F≤5k 0.128 + 0.1 0.16 + 0.1
5k<F≤10k 0.24 + 0.2 0.3 + 0.2
10k<F≤30k 0.96 + 0.4 1.2 + 0.4
3mA 0.30000 mA~
3.30000 mA
10≤F≤20 0.128 + 0.1 0.16 + 0.1 10 nA 7 V 200μH
20<F≤45 0.096 + 0.1 0.12 + 0.1
45<F≤1k 0.064 + 0.1 0.08 + 0.1
1k<F≤5k 0.128 + 0.2 0.16 + 0.2
5k<F≤10k 0.24 + 0.3 0.3 + 0.3
10k<F≤30k 0.96 + 0.5 1.2 + 0.5
30 mA 3.0000 mA~
33.0000 mA
10≤F≤20 0.096 + 2 0.12 + 2 100 nA 7 V 50μH
20<F≤45 0.064 + 2 0.08 + 2
45<F≤1k 0.032 + 2 0.04 + 2
1k<F≤5k 0.064 + 2 0.06 + 2
5k<F≤10k 0.08 + 3 0.1 + 3
10k<F≤30k 0.24 + 4 0.3 + 4
300 mA 30.000 mA~
330.000 mA
10≤F≤20 0.096 + 20 0.12 + 20 1 μA 5 V 50μH
20<F≤45 0.064 + 20 0.08 + 20
45<F≤1k 0.032 + 20 0.04 + 20
1k<F≤5k 0.048 + 40 0.06 + 40
5k<F≤10k 0.08 + 100 0.1 + 100
10k<F≤30k 0.24 + 200 0.3 + 200
1 A 0.10000 A~
1.10000 A
10≤F≤45 0.096 + 100 0.12 + 100 10μA 5 V 2.5μH
45<F≤1k 0.032 + 80 0.04 + 80
1k<F≤5k 0.048 + 500 0.06 + 500
5k<F≤10k 0.08 + 1000 0.1 + 1000
3 A 1.00000 A~
3.30000 A
10≤F≤45 0.096 + 100 0.12 + 100 10μA 4 V 2.5μH
45<F≤1k 0.032 + 80 0.04 + 80
1k<F≤5k 0.048 + 500 0.06 + 500
5k<F≤10k 0.08 + 2000 0.1 + 2000
20 A 3.0000 A~
20.5000 A
45≤F≤100 0.048 + 1500 0.06 + 1500 100μA 3 V 1μH
100<F≤1k 0.064 + 1500 0.08 + 1500
1k<F≤5k 0.096 + 3000 0.12 + 3000
  1. Manual or automatic range switch.
  2. Open-circuit and overload protection.
  3. Supports continuous and long-term output of current under full range.
6.6 Sinusoidal Wave Frequency Output
Range Resolution Accuracy (Tcal±5°C)
10.00000 Hz ≤ F ≤ 99.99999 Hz 10 μHz ±0.005%
100.0000 Hz ≤ F ≤ 999.9999 Hz 0.1 mHz ±0.005%
1.000000 kHz ≤ F ≤ 9.999999 kHz 1 mHz ±0.005%
10.00000 kHz ≤ F ≤ 99.99999 kHz 10 mHz ±0.005%
100.0000 kHz ≤ F ≤ 500.0000 kHz 0.1 Hz ±0.005%

6.7 Phase and Power Factor Output
Phase Accuracy(Tcal±5°C)
10~20Hz 20~45Hz 45~1kHz 1k~5kHz 5k~10kHz 10k~30kHz
φ 0.1° 0.1° 0.05° 0.5° 1.0° 2.0°
phase
(φ)
Power factor
(λ)
Power accuracy caused by phase[3]
10~20Hz 20~45Hz 45~1kHz 1k~5kHz 5k~10kHz 10k~30kHz
1.00000 0.000% 0.000% 0.000% 0.004% 0.015% 0.061%
10° 0.98481 0.031% 0.031% 0.015% 0.158% 0.323% 0.676%
20° 0.93969 0.064% 0.064% 0.032% 0.321% 0.650% 1.331%
30° 0.86603 0.101% 0.101% 0.050% 0.508% 1.023% 2.076%
40° 0.76604 0.147% 0.147% 0.073% 0.736% 1.480% 2.989%
50° 0.64279 0.208% 0.208% 0.104% 1.044% 2.095% 4.220%
60° 0.50000 0.302% 0.302% 0.151% 1.515% 3.038% 6.106%
70° 0.34202 0.480% 0.480% 0.240% 2.401% 4.810% 9.649%
80° 0.17365 0.990% 0.990% 0.495% 4.953% 9.913% 19.853%
90° 0.00000 - - - - - -
Note: [1] Phase resolution: 0.001°;[2] Power factor resolution: 0.000 01;[3] Other power factor accuracy calculation formula:


6.8 AC/DC Power Output
Frequency
(Hz)
Voltage Range
(U)
Current Range
(I)
Phase Range
(φ)
Power Factor Range
(λ)
DC 0~±1020 V 0~±20.5 A - -
10~45 30 mV~33 V 3 mA~3.3 A 0.000°~359.999° -1~0~1
45~1k 30 mV~1020 V 3 mA~20.5 A 0.000°~359.999° -1~0~1
1k~5k 3 V~1020 V 30 mA~3.3 A 0.000°~359.999° -1~0~1
5k~10k 3 V~1020 V 30 mA~3.3 A 0.000°~359.999° -1~0~1
10k~30k 3 V~330 V 30 mA~330 mA 0.000°~359.999° -1~0~1

6.9 Pulse Frequency Output
Range [1] Resolution Accuracy, (Tcal±5°C)
±(ppm*RD + μHz)
Shake
1.000 00 Hz ≤ F ≤ 9.999 99 Hz 10 μHz 20 + 20 <20 ns
10.000 0 Hz ≤ F ≤ 99.999 9 Hz 0.1 mHz
100.000 Hz ≤ F ≤ 999.999 Hz 1 mHz
1.000 00 kHz ≤ F ≤ 9.999 99 kHz 10 mHz
10.000 0 kHz ≤ F ≤ 99.999 9 kHz 0.1 Hz
100.000 kHz ≤ F ≤ 999.999 kHz 1 Hz
1.000 00 MHz ≤ F ≤ 2.000 00 MHz 10 Hz
Note [1]: The output type is TTL level.


6.10 Thermocouple Output and Measurement (optional)
Type [1] Output Range[2] [3] Accuracy
(Tcal±5°C)[4](°C)
90 days 1 year
B 410°C ~ 600°C 0.33 0.35
600°C ~ 900°C 0.26 0.28
900°C ~ 1800°C 0.20 0.22
E -200°C ~ 0°C 0.09 0.10
0°C ~ 600°C 0.06 0.08
600°C ~ 1000°C 0.08 0.10
J -200°C ~ -100°C 0.12 0.13
-100°C ~ 750°C 0.07 0.08
750°C ~ 1200°C 0.08 0.10
K -200°C ~ -100°C 0.15 0.16
-100°C ~ 1000°C 0.08 0.10
1000°C ~ 1370°C 0.10 0.12
N -200°C ~ -100°C 0.21 0.22
-100°C ~ 400°C 0.07 0.09
400°C ~ 1300°C 0.09 0.11
R -50°C ~ 50°C 0.36 0.38
50°C ~ 300°C 0.25 0.27
300°C ~ 1000°C 0.18 0.20
1000°C ~ 1750°C 0.18 0.20
S -50°C ~ 50°C 0.36 0.38
50°C ~ 300°C 0.25 0.27
300°C ~ 1000°C 0.18 0.20
1000°C ~ 1750°C 0.21 0.23
T -200°C ~ 100°C 0.13 0.15
-100°C ~ 0°C 0.08 0.11
0°C ~ 400°C 0.06 0.08
Note [1]: Use external compensation, S, R, B, K, N, E, J, T conform to ITS-90 international temperature standard;
Note [2]: Temperature resolution: 0.01 ° C;
Note [3]: Internal resistance of output source: 10 Ω;
Note [4]: The thermocouple error is not included.
  1. Voltage output/measurement range: -10 mV~ 80 mV
  2. 7 digits decimal display
  3. Ripple coefficient: <0.5%

6.11 RTD Output(optional)
Type Output Range[1] Accuracy, (Tcal±5°C), °C
90 days 1 year
Pt385, 100 Ω -200°C ~ 850°C 0.04 0.05
Pt385, 200 Ω -200°C ~ 320°C 0.30 0.35
320°C ~ 850°C 0.35 0.40
Pt385, 500 Ω -200°C ~ -30°C 0.04 0.05
-30°C ~ 850°C 0.13 0.15
Pt385, 1000 Ω -200°C ~ 850°C 0.07 0.09
Cu50 -50°C ~ 150°C 0.07 0.09
Cu100 -50°C ~ 150°C 0.04 0.05
Note[1]: Resolution: 0.001°C

7. General Specifications

Power supply AC (220±22) V, (50±2) Hz
Maximum power consumption 550 VA
Warm up time Twice the time since last warmed up, to a maximum of 30 minutes.
Temperature performance Operating temperature: 0°C ~ 50°C
Calibration temperature: 15°C  ~35°C
Storage temperature: - -20°C~70°C
Humidity performance Operating humidity: <80% @ 30°C, <70% @ 40°C, <40% @ 50°C
Storage humidity: <95%, No condensation
Communication interface RS232×1,USB×1,LAN×1
Dimensions 444 mm(W)× 510 mm (D) × 205 mm (H), Handles and feets excluded.
 
Company Profile
TD1870 Multi-function Calibrator for Calibrating 5.5 DMM &amp; Below

TD1870 Multi-function Calibrator for Calibrating 5.5 DMM &amp; Below

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier