Customization: | Available |
---|---|
After-sales Service: | Life Time |
Warranty: | 12 Months Excellent After-sales Service |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
☆ Analog resistance output |
|
☆ Wide range of current measurement |
|
☆ AC/DC comprehensive measurement |
|
|
|
S/N | Function |
1 | Current overshoot: the maximum test current is displayed in DC mode, which is convenient for calculating the working current overshoot; |
2 | Waveform display: With oscilloscope function, the waveform of the measured current can be displayed in real time. |
3 | Ripple measurement: the instrument directly displays the ripple measurement results on the screen, which is convenient for users to read. |
|
|
S/N | Function |
1 | Harmonic distortion: The instrument directly calculates two types of harmonic distortion, THD/T (harmonics relative to full wave) and THD/F (harmonics relative to fundamental waves). |
2 | Harmonic data: display the amplitude (RMS), content (%) and phase of the 2nd~32nd harmonics. |
3 | DC component: display the DC component in the AC current signal. |
4 | Waveform display: With waveform display function, the waveform of the measured current can be displayed in real time. |
|
|
S/N | Function |
1 | Integration period: The integration period can be set in the range of 0.5 s ~ 20 s (default 1s), which is convenient for users to set sampling data according to actual needs; |
2 | Statistical analysis: Real-time recording and statistical test data, including current Max, Min, Avg, Span, Stab, S. dev, Time, test times N, etc. |
Range | Resolution | Measurement uncertainty ( k=2 ). ( ppm*RD + ppm*RG ) [1] |
Temperature coefficient @ ( 15 ~ 30 ) °C ( ppm*RG/ºC ) |
||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | ||
100 mA | 1 μA | 200 + 200 | 100 + 100 | 10 | 4 |
200 mA | 1 μA | 200 + 100 | 100 + 50 | 10 | 4 |
500 mA | 1 μA | 200 + 100 | 100 + 50 | 10 | 4 |
1 A | 10 μA | 200 + 100 | 100 + 50 | 10 | 4 |
2 A | 10 μA | 200 + 100 | 100 + 50 | 10 | 4 |
5 A | 10 μA | 200 + 100 | 100 + 50 | 10 | 4 |
10 A | 100 μA | 200 + 100 | 100 + 50 | 10 | 4 |
20 A | 100 μA | 200 + 100 | 100 + 50 | 10 | 4 |
50 A | 100 μA | 200 + 100 | 100 + 50 | 10 | 4 |
100 A [2] | 1 mA | 200 + 100 | 100 + 50 | 10 | 4 |
200 A [2] | 1 mA | 200 + 100 | 100 + 50 | 10 | 4 |
500 A [2] | 1 mA | 200 + 100 | 100 + 50 | 10 | 4 |
Note [1]: RD is the reading value, RG is the range value; [2] : 100 A, 200 A, 5 00 A range is optional, and the TH0550T through-core AC/DC current sensor must be selected to the appropriate specifications |
• Measuring range (TD1450-X-50 A, maximum capacity: 5 0 A): 10 m A ~ 60 A
Measuring range (TD1450-X-100 A, maximum range: 100 A): 10 mA ~ 120 A
Measuring range (TD1450-X-200 A, maximum range: 200 A): 10 mA ~ 240 A
Measuring range (TD1450-X-500 A, maximum range: 500 A): 10 mA ~ 600 A
• Display digits: 6-digit decimal display
• Ripple measurement band: 1 Hz ~ 1 kHz, measurement uncertainty (k=2): 0.02%*RG, rms
• Input protection: can withstand 2 times the rated current and 5 s overload
Range | Resolution | Measurement uncertainty ( k=2 ). ( ppm*RD + ppm*RG ) [1] |
Temperature coefficient @ ( 15~30 )°C ( ppm*RG/ºC ) |
||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | ||
100 mA | 1 μA | 500 + 500 | 300 + 200 | 20 | 10 |
200 mA | 1 μA | 500 + 500 | 300 + 200 | 20 | 10 |
500 mA | 1 μA | 500 + 500 | 300 + 200 | 20 | 10 |
1 A | 10 μA | 500 + 500 | 300 + 200 | 20 | 10 |
2 A | 10 μA | 500 + 500 | 300 + 200 | 20 | 10 |
5 A | 10 μA | 500 + 500 | 300 + 200 | 20 | 10 |
10 A | 100 μA | 500 + 500 | 300 + 200 | 20 | 10 |
20 A | 100 μA | 500 + 500 | 300 + 200 | 20 | 10 |
50 A | 100 μA | 500 + 500 | 300 + 200 | 20 | 10 |
100 A [2] | 1 mA | 500 + 500 | 300 + 200 | 20 | 10 |
200 A [2] | 1 mA | 500 + 500 | 300 + 200 | 20 | 10 |
500 A [2] | 1 mA | 500 + 500 | 300 + 200 | 20 | 10 |
Note [1]: RD is the reading value, RG is the range value; [2] : 100 A, 200 A, 500 A range is optional, and the TH 0550 T through-core AC/DC current sensor must be selected |
• Measuring range (TD145 0-X-50 A-B size, maximum capacity: 50 A): 10 mA ~ 60 A
Measuring range (TD145 0-X-100 A-B size, maximum capacity: 100 A): 10 mA ~ 120 A
Measuring range (TD145 0-X-200 A-B size, maximum capacity: 200 A): 10 mA ~ 240 A
Measuring range (TD145 0-X-500 A-B size, maximum capacity: 500 A): 10 mA ~ 600 A
• Display digits: 6-digit decimal display
• AC frequency: 45 Hz ~ 65 Hz, measurement uncertainty (k=2): 0.01 Hz, harmonic measurement: 2nd ~ 32nd times
• Input protection: can withstand 2 times the rated current and 5 s overload
Current range | The setting range of the resistance value R | Adjust the fineness | Measurement uncertainty (k=2, ppm*RD+R0) [1]. | |
Class 0.05 | Class 0.02 | |||
500 A [2] | 1 μΩ ≤ R ≤ 400 μΩ | 2 nΩ | 500 + 20 nΩ | 200 + 10 nΩ |
400 μΩ < R ≤ 4 mΩ | 20 nΩ | 500 | 200 | |
4 mΩ < R ≤ 40 mΩ | 200 nΩ | 500 | 200 | |
200 A [2] | 3 μΩ ≤ R ≤ 1 mΩ | 10 nΩ | 500 + 30 nΩ | 200 + 20 nΩ |
1 mΩ < R ≤ 10 mΩ | 100 nΩ | 500 | 200 | |
10 mΩ < R ≤ 100 mΩ | 1 mΩ | 500 | 200 | |
100 A [2] | 5 mH ≤ R ≤ 2 mΩ | 10 nΩ | 500 + 60 nΩ | 200 + 40 nΩ |
2 mΩ < R ≤ 20 mΩ | 100 nΩ | 500 | 200 | |
20 mΩ < R ≤ 200 mΩ | 1 mΩ | 500 | 200 | |
50 A | 10 mΩ ≤ R ≤ 4 mΩ | 20 nΩ | 500 + 120 nΩ | 200 + 80 nΩ |
4 mΩ < R ≤ 40 mΩ | 200 nΩ | 500 | 200 | |
40 mΩ < R ≤ 400 mΩ | 2 mΩ | 500 | 200 | |
20 A | 30 mΩ ≤ R ≤ 10 mΩ | 100 nΩ | 500 + 0.3 mΩ | 200 + 0.2 mΩ |
10 mΩ < R ≤ 100 mΩ | 1 mΩ | 500 | 200 | |
100 mΩ < R ≤ 1 Ω | 10 mΩ | 500 | 200 | |
10 A | 50 mH ≤ R ≤ 20 mΩ | 100 nΩ | 500 + 0.6 mΩ | 200 + 0.4 μΩ |
20 mΩ < R ≤ 200 mΩ | 1 mΩ | 500 | 200 | |
200 mΩ < R ≤ 2 Ω | 10 mΩ | 500 | 200 | |
5 A | 100 μΩ ≤ R ≤ 40 mΩ | 200 nΩ | 500 + 1.2 mΩ | 200 + 0.8 mΩ |
40 mΩ < R ≤ 400 mΩ | 2 mΩ | 500 | 200 | |
400 mΩ < R ≤ 4 Ω | 20 mΩ | 500 | 200 | |
2 A | 300 μΩ ≤ R ≤ 100 mΩ | 1 mΩ | 500 + 3 mΩ | 200+ 2 mΩ |
100 mΩ < R ≤ 1 Ω | 10 mΩ | 500 | 200 | |
1 Ω < R ≤ 10 Ω | 100 mΩ | 500 | 200 | |
1 A | 500 μΩ ≤ R ≤ 200 mΩ | 1 mΩ | 500 + 6 mΩ | 200 + 4 mΩ |
200 mΩ < R ≤ 2 Ω | 10 mΩ | 500 | 200 | |
2 Ω < R ≤ 20 Ω | 100 mΩ | 500 | 200 | |
500 mA | 1 m Ω ≤ R ≤ 400 mΩ | 2 mΩ | 500 + 12 mΩ | 200 + 8 mΩ |
400 mΩ < R ≤ 4 Ω | 20 mΩ | 500 | 200 | |
4 Ω < R ≤ 40 Ω | 200 mΩ | 500 | 200 | |
200 mA | 3 m Ω ≤ R ≤ 1 Ω | 10 mΩ | 500 + 30 mΩ | 200 + 20 mΩ |
1 Ω < R ≤ 10 Ω | 100 mΩ | 500 | 200 | |
10 Ω < R ≤ 100 Ω | 1 mΩ | 500 | 200 | |
1,00 mA | 5 m Ω ≤ R ≤ 2 Ω | 10 mΩ | 500 + 60 mΩ | 200 + 50 mΩ |
2 Ω < R ≤ 20 Ω | 100 mΩ | 500 | 200 | |
20 Ω < R ≤ 200 Ω | 1 mΩ | 500 | 200 | |
Note [1]: RD is the reading value, RG is the range value; [2]: 100 A, 200 A, 500 A range is optional, and the TH 0550T through-core AC/DC current sensor must be selected. |
• Resistance analog range (TD145 0-X-50 A specification, maximum range: 50 A): 10 μΩ ~ 200 Ω
Resistance analog range (TD145 0-X-100 A, maximum range: 100 A) :5 μΩ ~ 200 Ω
Resistance analog range (TD145 0-X-200 A, maximum range: 200 A): 3 μΩ ~ 200 Ω
Resistance analog range (TD145 0-X-500 A, maximum range: 500 A): 1 μΩ ~ 200 Ω
• Display digits: 6-digit decimal display, set the resistance value through the number keys.
Current range | The setting range of the resistance value R | Adjust the fineness | Measurement uncertainty ( k=2, ppm*RD + R0 ) [1]. | |
Class 0.05 | Class 0.02 | |||
500 A [2] | 30 μΩ ≤ R ≤ 300 μΩ | 2 nΩ | 1000 + 0.2 μΩ | 500 + 0.1 mΩ |
300 μΩ < R ≤ 3 mΩ | 20 nΩ | 1000 | 500 | |
3 mΩ < R ≤ 30 mΩ | 200 nΩ | 1000 | 500 | |
200 A [2] | 75 mΩ ≤ R ≤ 750 μΩ | 10 nΩ | 1000 + 0.4 μΩ | 500 + 0.2 mΩ |
750 μΩ< R ≤ 7.5 mΩ | 100 nΩ | 1000 | 500 | |
7.5 mΩ < R ≤ 75 mΩ | 1mΩ | 1000 | 500 | |
100 A [2] | 150 mΩ ≤ R ≤ 1.5 mΩ | 10 nΩ | 1000 + 1 mΩ | 500 + 0.5 mΩ |
1.5 mΩ < R ≤ 15 mΩ | 100 nΩ | 1000 | 500 | |
15 mΩ < R ≤ 150 mΩ | 1 mΩ | 1000 | 500 | |
50 A | 300 mΩ ≤ R ≤ 3 mΩ | 20 nΩ | 1000 + 2 μΩ | 500 + 1 mΩ |
3 mΩ < R ≤ 30 mΩ | 200 nΩ | 1000 | 500 | |
30 mΩ < R ≤ 300 mΩ | 2 mΩ | 1000 | 500 | |
20 A | 750 mΩ ≤ R ≤ 7.5 mΩ | 100 nΩ | 1000 + 4 μΩ | 500 + 2 mΩ |
7.5 mΩ < R ≤ 75 mΩ | 1 mΩ | 1000 | 500 | |
75 mΩ < R ≤ 750 mΩ | 10 mΩ | 1000 | 500 | |
10 A | 1.5 mΩ ≤ R ≤ 15 mΩ | 100 nΩ | 1000 + 10 μΩ | 500 + 5 mΩ |
15 mΩ < R ≤ 150 mΩ | 1 mΩ | 1000 | 500 | |
150 mΩ < R ≤ 1.5 Ω | 10 mΩ | 1000 | 500 | |
5 A | 3 mΩ ≤ R ≤ 30 mΩ | 200 nΩ | 1000 + 20 μΩ | 500 + 10 mΩ |
30 mΩ < R ≤ 300 mΩ | 2 mΩ | 1000 | 500 | |
300 mΩ < R ≤ 3 Ω | 20 mΩ | 1000 | 500 | |
2 A | 7.5 mΩ ≤ R ≤ 75 mΩ | 1 mΩ | 1000 + 40 mΩ | 500 + 20 mΩ |
75 mΩ < R ≤ 750 mΩ | 10 mΩ | 1000 | 500 | |
750 mΩ < R ≤ 7.5 Ω | 100 mΩ | 1000 | 500 | |
1 A | 15 mΩ ≤ R ≤ 150 mΩ | 1 mΩ | 1000 + 100 μΩ | 500 + 50 mΩ |
150 mΩ < R ≤ 1.5 Ω | 10 mΩ | 1000 | 500 | |
1.5 Ω < R ≤ 15 Ω | 100 mΩ | 1000 | 500 | |
500 mA | 30 mΩ ≤ R ≤ 300 mΩ | 2 mΩ | 1000 + 200 μΩ | 500 + 100 mΩ |
300 mΩ < R ≤ 3 Ω | 20 mΩ | 1000 | 500 | |
3 Ω < R ≤ 30 Ω | 200 mΩ | 1000 | 500 | |
200 mA | 75 mΩ ≤ R ≤ 750 mΩ | 10 mΩ | 1000 + 400 μΩ | 500 + 200 mΩ |
750 mΩ < R ≤ 7.5 Ω | 100 mΩ | 1000 | 500 | |
7.5 Ω < R ≤ 75 Ω | 1 mΩ | 1000 | 500 | |
100 mA | 75 mΩ ≤ R ≤ 1.5 Ω | 10 mΩ | 1000 + 1000 μΩ | 500 + 500 μΩ |
1.5 Ω < R ≤ 15 Ω | 100 mΩ | 1000 | 500 | |
15 Ω < R ≤ 150 Ω | 1 mΩ | 1000 | 500 | |
Note [1]: RD is the reading value, RG is the range value; [2] : 100 A, 200 A, 5 00 A range is optional, and the TH 0550 T through-core AC/DC current sensor must be selected. |
• Resistance analog range (TD1450-X-50 A-B specification, maximum range: 50 A): 300 μΩ ~ 150 Ω
Resistance analog range (TD1450-X-100 A-B specification, maximum range: 100 A): 150 μΩ ~ 150 Ω
Resistance analog range (TD1450-X-200 A-B specification, maximum capacity: 200 A): 75 μΩ ~ 150 Ω
Resistance analog range (TD1450-X-500 A-B specification, maximum range: 500 A): 30 μΩ ~ 150 Ω
• Display digits: 6-digit decimal display, set the resistance value through the number keys.
Power supply | AC ( 220 ± 22 )V,( 50 ± 2 )Hz |
Maximum power consumption | 100 VA |
Warm-up time | ≥ 30 min |
Temperature performance | Working temperature: 18°C ~ 28°C; Storage temperature: -20°C ~ 70°C |
Humidity performance | Operating humidity: ( 40% ~ 80% ) R· H, no condensation Storage humidity: <80% R· H, no condensation |
Communication interface | LAN,USB,RS232 |
Quality | Approx 12.5 kg |
Size | 400 mm (W) X 300 mm (D) X 190 mm (H) (excluding handlebars and feet). |