☆ Wide range of current measurement |
![]() |
|
☆ AC/DC comprehensive measurement |
![]() |
|
☆ Precision small signal voltage measurement |
![]() |
![]() |
|
☆ Power calculation function |
![]() |
![]() |
|
☆ DC ripple / AC harmonic measurement |
|
![]() |
|
S/N | Function |
1 | With DC ripple test function, it can measure the ripple content in the range of 1 Hz ~ 5 kHz. The ripple waveform can be displayed in real time, and the rms value (RMS) and peak-to-peak value (P-P) of the ripple can be measured. |
2 | AC power measurement also has an oscilloscope function, which can display the waveform of the AC signal under test in real time. |
3 | Calculate two types of harmonic distortion: THD/T (harmonic relative to full wave) and THD/F (harmonic relative to fundamental wave). |
4 | The amplitude (RMS), content (%) and phase of the 2nd ~ 63rd harmonic of each phase voltage or current can be analyzed in real time. |
5 | Visualize the spectrum of each harmonic (100% fundamental) in the form of a histogram. |
☆ Data statistical analysis function |
|
![]() |
|
S/N | Function |
1 | Data statistical analysis: calculate the maximum (Max), minimum value (min), peak-peak (P-P), average value (AVG), standard deviation (S.dev), divergence (Div), etc. of the measured electricity. |
2 | Power Trend Test: Curve the power over time in real time during the test cycle. |
3 | Normal distribution histogram: Displays the distribution of the amount of electricity being counted during the test period. |
Voltage range | Resolution | Measurement uncertainty (k=2), (ppm*RD + ppm*RG or V) [1]. | |||
DC | 40 Hz≤F≤200 Hz | 200 Hz<F≤1 kHz | Temperature coefficient (/°C) @(15 ~ 30)°C |
||
100mV | 10 nV | 20 + 2 m | 80 + 40 | 100 + 50 | 0.2 |
300 mV | 10 nV | 12 + 15 | 80 + 40 | 100 + 50 | 0.2 |
1 V | 0.1 μV | 12 + 8 | 80 + 40 | 100 + 50 | 0.1 |
3 V | 0.1 μV | 12 + 8 | 80 + 40 | 100 + 50 | 0.1 |
10 V | 1 μV | 12 + 8 | 80 + 40 | 100 + 50 | 0.1 |
30 V | 1 μV | 12 + 8 | 80 + 40 | 100 + 50 | 0.1 |
100 V | 10 μV | 12 + 8 | 80 + 40 | 100 + 50 | 0.1 |
300 V | 10 μV | 12 + 8 | 80 + 40 | 100 + 50 | 0.1 |
1000 V | 0.1 mV | 12 + 8 | 80 + 40 | 100 + 50 | 0.1 |
Note: [1] RD is the reading value and RG is the range value |
Current range | Resolution | Measurement uncertainty (k=2), (ppm*RD +ppm*RG or nA) | |||
DC | 40Hz≤F≤200Hz | 200Hz<F≤1 kHz | Temperature coefficient (/°C) @ (15 ~ 30)°C |
||
100 μA | 10 pA | 30 + 3 nA | 150 + 50 | 200 + 50 | 0.1 |
300 μA | 10 pA | 30 + 10 nA | 150 + 50 | 200 + 50 | 0.1 |
1mA | 0.1 nA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
3 mA | 0.1 nA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
10 mA | 1 nA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
30 mA | 1 nA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
100 mA | 10 nA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
300 mA | 10 nA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
1 A | 0.1 μA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
3 A | 0.1 μA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
10 A | 1 μA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
30 A | 1 μA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
100 A | 10 μA | 20 + 10 | 100 + 50 | 150 + 50 | 0.1 |
200 A [2] | 10 μA | 30 + 10 | 150 + 50 | 200 + 50 | 0.1 |
500 A [2] | 10 μA | 30 + 10 | 150 + 50 | 200 + 50 | 0.1 |
Note [2]: 200 A and 500 A range currents are optional, and optional current sensors such as TH0540 must be used for range extension. |
Voltage range | Resolution | Absolute measurement uncertainty (k=2), ± (ppm*RD + ppm*RG or μV). | |||
DC | 40Hz≤F≤200Hz | 200Hz<F≤1 kHz | Temperature coefficient (/°C) @ (15 ~ 30)°C |
||
1 mV | 0.1n V | 50 + 0.3 μV | - | - | 0.5 |
5 mH | 0.1n V | 50 + 0.5 μV | - | - | 0.5 |
20 mV | 1 nV | 50 + 0.6 μV | 100 + 3.0 μV | 120 + 4.0 μV | 0.5 |
100 mV | 10 nV | 40 + 15 | 80 + 40 | 100 + 50 | 0.2 |
500 mV | 10 nV | 40 + 15 | 80 + 40 | 100 + 50 | 0.2 |
2 V | 0.1 mV | 30 + 10 | 80 + 40 | 100 + 50 | 0.1 |
10 V | 1 mV | 30 + 10 | 80 + 40 | 100 + 50 | 0.1 |
DC power / electrical energy | Measuring range | Combination of DC voltage and DC current |
Measurement uncertainty | DC voltage uncertainty + DC current uncertainty | |
AC power / electrical energy | Measuring range | The combination of AC voltage and AC current |
Measurement uncertainty | AC voltage uncertainty + AC current uncertainty, | PF|=1 | |
Electrical energy pulses | Standard energy pulse input | It can directly receive the photoelectric pulse of the energy of the meter to be checked |
Standard energy pulse output | The signal amplitude is 5 V at TTL level FH=120 kHz × power value÷ voltage range value÷ current range value FL=120 kHz × power value÷ voltage range value÷ current range value÷ 10000 |
|
Electrical energy error display | Automatic display with a resolution of 0.00001%, 8-bit display |
Power supply | AC (220 ± 22 ) V, ( 50 ± 2 ) Hz, maximum power consumption: 100 VA |
Warm-up time | 30 minutes |
Temperature performance | Working temperature: 15°C ~ 35°C; Storage temperature: -10°C ~ 50°C |
Humidity performance | Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C Storage humidity: (20% ~ 80%) R· H, no condensation |
altitude | < 3000 m |
Quality | Approx. 11 kg |
Communication interface | RS232 |
Size | 400 mm(W) × 302 mm(D) × 206 mm(H) |
![]() |