TA4600 Electrical Power Quality Analyzer Calibrator Power Source

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 12 Months Excellent After-Sales Service
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013
  • TA4600 Electrical Power Quality Analyzer Calibrator Power Source
  • TA4600 Electrical Power Quality Analyzer Calibrator Power Source
  • TA4600 Electrical Power Quality Analyzer Calibrator Power Source
  • TA4600 Electrical Power Quality Analyzer Calibrator Power Source
  • TA4600 Electrical Power Quality Analyzer Calibrator Power Source
  • TA4600 Electrical Power Quality Analyzer Calibrator Power Source
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TA4600
Power
Electricity
Voltage Output
1 V ~ 1008 V(AC/DC)
Current Output
10 mA ~ 21 A(AC/DC)
LCD Display
With LCD Display
Customized
Non-Customized
Frequency Range
16 Hz ~ 850 Hz
Voltage Accuracy
0.005% @45 Hz~65 Hz
Current Accuracy
0.005%*RD+2.5μA @45 Hz~65 Hz
Power Energy Accuracy
0.01%@ (PF: 0.5 ~ 1)
Accuracy of U-I Phase
0.003°@ 45 Hz~65 Hz
U&I Harmonics
2nd~99th @50Hz / 60Hz
Interharmonic Frequency Range
16 Hz ~ 6 kHz
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Product Description

TA4600 Electrical Power Quality Standard Power Source

TA4600 Electrical Power Quality Analyzer Calibrator Power Source
 


1.Features

  1. DC / Single-phase / Three-phase Voltage Output: 1 V ~ 1008 V;
  2. DC / Single-phase / Three-phase Current Output: 10 mA ~ 21 A;
  3. Fundamental Frequency Range: 16 Hz ~ 850 Hz;
  4. Voltage Accuracy: 0.005% @45 Hz~65 Hz;
  5. Current Accuracy: 0.005%*RD+2.5μA @45 Hz~65 Hz;
  6. Power Energy Accuracy: 0.01%@ (PF: 0.5 ~ 1);
  7. Optimal Accuracy of U-I Phase: 0.003°@ 45 Hz~65 Hz;
  8. Voltage and Current Harmonics: 2nd~99th @50Hz / 60Hz
  9. Interharmonic Frequency Range: 16 Hz ~ 6 kHz
2. Function
 
  1. Three-phase Virtual Power Standard Source: Each phase voltage, current, and U-I phase can be controlled independently, supporting three-phase unified adjustment.
  2. Power / Energy Signal Output: Can provide standard power and energy signals for traceability calibration.
  3. Harmonic Output Function: Both voltage and current can be superimposed on the fundamental wave with the 2nd to 99th harmonics @50Hz / 60Hz. The amplitude and phase (relative to the fundamental wave) of each harmonic can be set independently.
  4. Energy Testing: It has pulse input/output function and built-in energy error comparator, which can be used for error detection of electric energy meters.
  5. Communication Interfaces: It has various communication interfaces such as RS232, USB, LAN, etc., which facilitates the establishment of a fully automatic test system.
  6. Reference Clock Output (CLK): Built-in 10 MHz high-precision reference clock output.
  7. Safety Protection Functions: The instrument includes voltage short circuit protection, current open circuit protection, overload protection, etc. The specially designed overcurrent fuse can also be easily replaced. It has the output limit setting function to prevent the output of large voltage or current from damaging the meter under test. The safety protection function can minimize accidental damage to the instrument due to mis-operation and greatly reduce user losses.
  8. Current Range Expansion: Programmable feedback control of the transconductance amplifier TA1000 can be achieved to achieve current range expansion.
  9.  
3. Specifications
3.1 Voltage Output

3.1.1 DC Voltage Output

Output Range 0~50%*range value (0 V~504 V)
Display Digit 7-digit display
Short Term Stability 0.003%/min
Annual Accuracy (tcal±5ºC) ± (0.009%*reading value+0.01%*range)
Maximum Load Current (Peak) 1 A (U ≤ 600V range); 71 mA (1000V range)
 

3.1.2 AC Voltage Output (Sinusoidal)

Output Range 1 V~1008 V
Output Frequency Range 16 Hz~850 Hz
Display Digits 7-digit display
Short Term Stability 0.0015%/min
Annual Accuracy (tcal±5ºC) 16 Hz≤F<45 Hz: ± (0.006%* reading value +0.001%* range)
45 Hz≤F≤65 Hz: ± (0.004%* reading value +0.001%* range) 
65 Hz<F≤850 Hz: ± (0.006%* reading value +0.001%* range)
Maximum Load Current (Peak) 1 A (U ≤ 600V range); 71 mA (1000V range)
Maximum Harmonic Distortion 0.016%* set value or 0.003%* range value, use the larger value of the two
 

3.1.3 AC Voltage Output (Non-sinusoidal)

Output Range 0~30%* range value
Harmonic Order 2nd~99th @50Hz / 60Hz
Short Term Stability 0.002%/min
Annual Accuracy (tcal±5ºC) 16 Hz≤F≤850 Hz:±(0.006%* reading value +0.002%* range)
850 Hz<F≤6 kHz:±(0.045%* reading value +0.0024%* range)
Maximum Load Current (Peak) 1 A(U ≤ 600V range); 71 mA(1000V range)
Maximum Harmonic Distortion 16 Hz≤F≤850 Hz: 0.016%* set value or 0.003%* range value, use the larger value of the two
850 Hz<F≤6 kHz: 0.25%* set value or 0.015%* range value, use the larger value of the two


3.2 Current Output

3.2.1 DC Current Output

Output Range 0 A~24 A
Display Digits 7-digit display
Short Term Stability 0.003%/min
Annual Accuracy (tcal±5ºC) ± (0.009%*reading value +0.01%*range)
Maximum Compliance Voltage (Peak) 14 Vpk@ (0.25A~10A range)


 

3.2.2 AC Current Output (Sinusoidal)

Output Range 0.1 A~80 A
Output Frequency Range 16 Hz~850 Hz
Display Digits 7-digit display
Short Term Stability 0.002%/min
Annual Accuracy 16 Hz≤F<45 Hz: ± (0.006%* reading value+0.002%* range)
45 Hz≤F≤65 Hz: ± (0.005%* reading value+0.001%* range)
65 Hz<F≤850 Hz: ± (0.006%* reading value+0.002%* range)
Maximum Compliance Voltage (Peak) 14 Vpk@(0.25A~10A range)
Maximum Harmonic Distortion 0.01%* set value or 0.003%* range value, use the larger value of the two
 

3.2.3 AC Current Output (Non-sinusoidal)

Output Range 0.1 A~24 A
Harmonic Order 2nd~99th @50Hz / 60Hz
Short Term Stability 0.002%/min
Annual Accuracy (tcal±5ºC) 16 Hz≤F≤850 Hz: ± (0.006%* reading value +0.002%* range)
850 Hz<F≤6 kHz: ± (0.04%* reading value +0.002%* range)
Maximum Compliance Voltage (Peak) 14 Vpk@(0.25A~10A range)
Maximum Harmonic Distortion 16 Hz≤F≤850 Hz: 0.016%* set value or 0.003% range value, use the larger value of the two
850 Hz<F≤6 kHz: 0.25%* set value or 0.015% range value, use the larger value of the two



3.3 AUX (Voltage on Current Terminals)

3.3.1 DC Voltage Output

Output Range 0~50%* range value (0 V~5 V)
Display Digits 7-digit display
Short Term Stability 0.003%/min
Annual Accuracy (tcal±5ºC) ±(0.009%* reading value +0.014%* range)
 

3.3.2 AC Voltage Output (Sinusoidal)

Output Range 0.05 V~10 V
Output Frequency Range 16 Hz~850 Hz
Display Digits 7-digit display
Short Term Stability 0.002%/min
Annual Accuracy (tcal±5ºC) 45 Hz≤F≤65 Hz: ± (0.005%* reading value +0.002%* range)
16 Hz<F≤850 Hz: ± (0.006%* reading value +0.002%* range)
Maximum Harmonic Distortion 0.010%* set value or 0.001%* range value, use the larger value of the two
 

3.3.3 AC Voltage Output (Non-sinusoidal)

Output Range 0~3V
Harmonic Order 2nd~99th @50Hz / 60Hz
Short Term Stability 0.002%/min
Annual Accuracy (tcal±5ºC) 16 Hz≤F≤850 Hz: ± (0.0065%* reading value +0.0020% range)
850 Hz<F≤6 kHz: ± (0.04%* reading value +0.0030%* range)
Maximum Harmonic Distortion 16 Hz≤F≤850 Hz: 0.010%* set value or 0.001%* range value, use the larger value of the two
850 Hz<F≤6 kHz: 0.100%* set value or 0.01%* range value, use the larger value of the two


3.4 Phase
Frequency Annual Accuracy (tcal ±5ºC)
>40% Range Voltage and Current Components 0.5%~40% Voltage or Current Component
U-I U-U
(Polyphase Operation)
U-I U-U
(Polyphase Operation)
16Hz ~ 69Hz  0.003° 0.005° 0.010° 0.010°
69Hz ~ 180Hz 0.007° 0.007° 0.017° 0.017°
180Hz ~ 450Hz 0.018° 0.025° 0.050° 0.050°
450Hz ~ 850Hz 0.033° 0.043° 0.070° 0.070°
850Hz ~ 3kHz 0.115° 0.150° 0.200° 0.200°
3kHz ~ 6kHz 0.230° 0.300° 0.450° 0.450°

3.5 Power

3.5.1 Sinusoidal Power Accuracy (Power Factor 1.0)

Current Range Power accuracy when current is 90% of the range (ppm) Power accuracy when current is 50% of the range (ppm)
When voltage is 62% ~ 70% of the range 650V & 1008V Range: 70%~75% When voltage is 7% ~ 100% of the range 650V&1008V Range: 70%~75%
23 V~ 90 V Range 180 V &360 V Range 23 V~ 90 V Range 180 V & 360 V Range
0 ~ 2A 62 64 64 72 74 74
5 A~ 20A  65 66 66 74 75 75


 

3.5.2 Sinusoidal Power Accuracy (Power Factor 0.5)

Current Range Power accuracy when current is 90% of the range (ppm) Power accuracy when current is 50% of the range (ppm)
When voltage is 62% ~ 70% of the range 650V &1008V Range: 70%~75% When voltage is 7% ~ 100% of the range 650V&1008V Range: 70%~75%
23 V~ 90 V Range 180 V& 360 V Range 23 V~ 90 V Range 180 V & 360 V Range
0 ~ 5A 93 94 94 100 101 101
10 A~ 20A  95 96 96 102 102 102
 

3.5.3 Non-sinusoidal Power Accuracy (Power Factor 1.0, 20%THD)

Current Range Power accuracy when current is 90% of the range (ppm) Power accuracy when current is 50% of the range (ppm)
When voltage is 62% ~ 70% of the range 650V & 1008V Range: 70%~75% When voltage is 7% ~ 100% of the range 650V& 1008V Range: 70%~75%
23 V~ 90 V Range 180 V& 360 V Range 23 V~ 90 V Range 180 V & 360 V Range
0 ~ 5A 97 98 98 103 105 105
10 A~ 20A  98 99 99 105 105 105
Note: For electric energy technical indicators, add 1ppm to the power indicator.

3.6 Energy

3.6.1 Pulse Input

Maximum Frequency 5MHz
Maximum Frequency 100 ns
Maximum Count Per Channel 232-1


 

3.6.2 Pulse and Gate-control Input

Input Low Level Max Value 1V
Input High Level Max Value 3V
Internal Pull-Up Value 135Ω and 940Ω to 4.5V nominal
Approximately equivalent to 150Ω/1kΩ to 5V nominal
Max Input Voltage 28V
Min Input Voltage 0V
 

3.6.3 Pulse Output

Drive Open-collector, optional internal 470Ω pull-up
Frequency Range 1mHz to 5MHz
Frequency Accuracy ±(10ppm+100nHz)
External Pull-Up Voltage 30V max
Sink Current Max 150mA
 

3.6.4 Gate-control Output

Drive Open-drain
Internal Pull-Up The value same as gate input
External Pull-Up Voltage 30V max
Sink Current Max 1A
 

3.6.5 Accuracy

Timing Accuracy ± (10ppm+100ns)
Gate-control Mode Accuracy ± (10ppm+100ns)
Packet Mode Accuracy (Ppm) ± (Output power (ppm)+10ppm+110 000/test period)



3.7 Flicker
Set Range ± 30% of setting value
Flicker Modulation Depth Accuracy 0.025%
Setting Accuracy of
Modulation Depth
0.001%
Modulation Envelope Shape Square or sine wave
Duty Factor
(Square Wave)
0.01% ~ 99.99%; accuracy = ±31 μs
Modulation Unit 0.5Hz ~ 40Hz
Modulation Frequency Accuracy <0.13%

3.8 Modulation Harmonics
Number of Modulating Harmonics 0 to all set harmonics
Modulation Depth Setting Range 0% ~ 100% of nominal harmonic voltage
Modulation Accuracy (0% ~ ±30%) ± 0.025%
Setting Accuracy of Modulation Depth 0.001%
Waveform Square wave or sine wave
Duty Factor (Square Wave) 0.01% ~ 99.99%
Modulation Frequency Range 0.008Hz~30Hz
Sine Wave Modulation Frequency Accuracy ± (50ppm+10μHz)
Square Wave Modulation Frequency Accuracy <1300ppm
Modulation Frequency Setting Resolution 0.001Hz



3.9 Interharmonics
Frequency Accuracy ± 500ppm
Amplitude Accuracy When 16Hz≤F<6kHz ± 1%
Amplitude Accuracy At >6kHz 4%
Max Value of Single Interharmonic The maximum value of interharmonic below 2850Hz is 30% of the range
Interharmonic Frequency Range 16Hz ~ 9khz

3.10 Voltage Swell and Sag
Min Duration 1ms
Max Duration 1min
Min Amplitude of Sag 0% of nominal output
Max Rapid Swell Full scale value or 140% of nominal output, whichever is smaller
Rise/Fall Time 100 μs ~ 30s configurable
Optional Repeat with Delay 0~ (60s ±31 μs)
Triggering Level Amplitude Accuracy ±0.025%*level value
Swell And Sag Level Amplitude Accuracy ±0.25%*level value
Trigger The falling edge of TTL is consistent with the trigger delay end time and remains low level of 10μs ~ 31μs

 

Company Profile
 

TA4600 Electrical Power Quality Analyzer Calibrator Power Source

TA4600 Electrical Power Quality Analyzer Calibrator Power SourceTA4600 Electrical Power Quality Analyzer Calibrator Power Source

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier