☆ Calibration of 2-wire/4-wire resistance (box) with internal reference |
|
|
☆ Calibration of 2-wire/4-wire resistance (box) with external reference |
|
|
|
S/N | Function |
1 | Visually display the changing trend of resistance measurement values. |
2 | Perform comprehensive analysis of resistance measurement values, including average (Avg), standard deviation (S.dev), and number of measurements (N). |
3 | Switchable trend charts, tables, and histograms for easy user analysis of measurement data. |
Advantages: The integration of system-wide testing and analysis functions eliminates the need for manual, time-consuming, and multiple measurement recording in traditional testing methods, significantly optimizing test operations and improving calibration efficiency. It also facilitates easy evaluation of the resistance testing process by test personnel. |
☆ Front Panel/ Side Panel | |
S/N | Function |
1 | Large-size LCD touch color screen with multi-channel voltage and waveform display, intuitive touch operation, enhancing the instrument's usability. |
2 | Button and knob operation panel allows users to easily set resistance calibration values, making metrology work more convenient. |
3 | Measurement terminals for tested resistance/resistance box (Rx) and standard reference resistance (Rs). |
4 | Foldable support feet elevate the instrument by approximately 15° for optimal operation and viewing angles. |
5 | Ergonomically designed handle for easy transportation of the instrument. |
☆ Rear Panel |
|
S/N | Function |
1 | High-power cooling fan: Efficient cooling system ensures long-term stable operation of the instrument. |
2 | Versatile communication interfaces: Includes RS232, USB, and LAN, enabling users to build fully automated testing systems. |
3 | Chassis Ground: Ensure the chassis is properly grounded before using the equipment. |
4 | Power Interface: Power input interface with switch and fuse. |
Resistance | Resolution | Test Current | Test Power | Measurement Uncertainty( k=2 , μΩ / Ω ) |
1 mΩ | 100 pΩ | 3.16 A ~ 10 A | 10 mW ~ 100 mW | 30+ KP[1]*2 |
10 mΩ | 1 nΩ | 1 A ~ 3.16 A | 10 mW ~ 100 mW | 20+ KP[1] *1 |
100 mΩ | 10 nΩ | 0.316 A ~ 1 A | 10 mW ~ 100 mW | 10+ KP[1] *0.5 |
1 Ω | 100 nΩ | 0.1 A ~ 0.316 A | 10 mW ~ 100 mW | 10 |
10 Ω | 1 μΩ | 31.6 mA ~ 100 mA | 10 mW ~ 100 mW | 10 |
100 Ω | 10 μΩ | 10 mA ~ 31.6 mA | 10 mW ~ 100 mW | 10 |
1 kΩ | 100 μΩ | 3.16 mA ~ 10 mA | 10 mW ~ 100 mW | 10 |
10 kΩ | 1 mΩ | 1 mA ~ 3.16 mA | 10 mW ~ 100 mW | 10 |
100 kΩ | 10 mΩ | 0.316 mA ~ 1 mA | 10 mW ~ 100 mW | 10 |
1 MΩ | 100 mΩ | 31.6 μA ~ 100 μA | 1 mW ~ 10 mW | 30 |
10 MΩ | 1 Ω | 3.16 μA ~ 10 μA | 0.1 mW ~ 1 mW | 50 |
Note 1:KP is the power coefficient,KP=100 mW/ test power |
Resistance | Resolution | Reference Resistance | Test Current | Test Power | Proportional Measurement Uncertainty( k=2 , μΩ / Ω ) |
1 mΩ | 100 pΩ | 10 Ω | 3.16 A ~ 10 A | 10 mW ~ 100 mW | 20+ KP[1]*2 |
10 mΩ | 1 nΩ | 10 Ω | 1 A ~ 3.16 A | 10 mW ~ 100 mW | 15+ KP[1]*1 |
100 mΩ | 10 nΩ | 10 Ω | 0.316 A ~ 1 A | 10 mW ~ 100 mW | 5+ KP[1] *0.5 |
1 Ω | 100 nΩ | 10 Ω | 0.1 A ~ 0.316 A | 10 mW ~ 100 mW | 5 |
10 Ω | 1 μΩ | 10 Ω | 31.6 mA ~ 100 mA | 10 mW ~ 100 mW | 5 |
100 Ω | 10 μΩ | 10 Ω | 10 mA ~ 31.6 mA | 10 mW ~ 100 mW | 5 |
1 kΩ | 100 μΩ | 100 Ω | 3.16 mA ~ 10 mA | 10 mW ~ 100 mW | 5 |
10 kΩ | 1 mΩ | 100 Ω | 1 mA ~ 3.16 mA | 10 mW ~ 100 mW | 8 |
100 kΩ | 10 mΩ | 1 kΩ | 0.316 mA ~ 1 mA | 10 mW ~ 100 mW | 8 |
1 MΩ | 100 mΩ | 10 kΩ | 31.6 μA ~ 100 μA | 1 mW ~ 10 mW | 20 |
Note 1:KP is the power coefficient,KP=100m W/ test power |
Power Supply | AC 90 V ~ 264 V / 47 Hz ~ 63 Hz |
Warm-Up Time | Minimum 1 hour. The warm-up time after power-off should be at least twice the duration of the power-off period |
Maximum Power Consumption | 150 VA |
Temperature Performance | Operating Temperature: 18 °C ~ 28 °C Storage Temperature: -20 °C ~ 60 °C |
Humidity Performance | Operating Humidity: (20% ~ 50%) R.H., non-condensing Storage Humidity: (15% ~ 80%) R.H., non-condensing |
Display Screen | LCD; 7 inch; |
Instrument Weight | About 13 kg |
Communication Interfaces | RS 232, LAN, USB(Type-B) |
Dimensions | W * D * H=435 mm * 398 mm * 177 mm(Excluding handle and support feet) |
Units: mm |