Customization: | Available |
---|---|
After-sales Service: | Life Time |
Warranty: | 12 Months Excellent for Service |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
NO. | Verification Items | Completion (√standard) |
Remarks | |
1 | Appearance, signs, power check | Observation | ||
2 | Accuracy Test | Initial inherent error test | √ | |
3 | Starting current test | √ | ||
4 | Test of no-load | √ | ||
5 | Meter constant test | √ | ||
6 | Electric energy display value combination error | √ | ||
7 | Demand indicating value error | √ | ||
8 | A clock test powered by a power supply | √ | ||
9 | Impact of the standby power supply on the clock | √ | ||
10 | Error consistency test | √ | ||
11 | Variation requirement test | √ | ||
12 | The load current rises and falls worse test | √ | ||
13 | Repeat test | √ | ||
14 | EMC | Voltage dips and interruptions | Optional-Fast change test of load current | |
15 | Resistance to Other Influences | Harmonic in voltage-current circuits -the 5st harmonic test | √ | |
16 | Harmonic in voltage-current circuits - square-wave test | √ | ||
17 | Harmonic in voltage-current circuits - peaked wave test | √ | ||
18 | Interharmonic in the current circuits - the pulse train triggers the waveform | √ | ||
19 | Odd harmonic in voltage-current circuits -waveform test triggered by 90 degree phase | √ | ||
20 | Impact Test of DC and Even Harmonics -waveform of half wave rectification | √ | ||
21 | Load unbalance test | √ | ||
22 | Voltage change test | √ | ||
23 | One or two-phase voltage interruption | √ | ||
24 | Frequency change test | √ | ||
25 | Reverse phase sequence test | √ | ||
26 | Auxiliary power supply voltage change test | Auxiliary power supply (optional) | ||
27 | Burden current fast change test | Burden current fast change test (optional) | ||
28 | Self-heating test | √ | ||
29 | High-order harmonic test | √ | ||
30 | Fault earthing test(Only for three-phase four-wire transformer type energy meter) | Fault earthing test (optional) | Only for class 0.05 TD3650 | |
31 | Electrical Performance Test | Power consumption test of voltage circuits | optional | |
32 | Power consumption test of current circuits | optional | ||
33 | Power consumption test of auxiliary power supply circuit | optional | ||
34 | IOT Electricity Meter | Harmonic power accuracy test | harmonic power(optional) | |
35 | Harmonic measurement accuracy test |
Range | Resolution | Short-term Stability ( % / min ) |
Accuracy ±(ppm of reading + ppm of range) [1] |
Distortion Factor ( % ) |
||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | |||
60 V | 0.1 mV | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.3 |
120 V | 1 mV | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.3 |
240 V | 1 mV | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.3 |
480 V | 1 mV | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.3 |
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%). |
Range | Resolution | Short-term Stability ( % / min ) |
Accuracy ±(ppm of reading + ppm of range) |
Distortion Factor ( % ) |
||
Class 0.05 | Class 0.02 | Class 0.05 | Class 0.02 | |||
5 mA | 10 nA | 0.03 | 0.02 | 400 + 300 | 240 + 160 | < 1 |
10 mA | 0.1 μA | 0.02 | 0.01 | 300 + 200 | 120 + 80 | < 0.5 |
20 mA | 0.1 μA | 0.02 | 0.01 | 300 + 200 | 120 + 80 | < 0.5 |
50 mA | 0.1 μA | 0.02 | 0.01 | 200 + 50 | 60 + 40 | < 0.5 |
100 mA | 1 μA | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.5 |
200 mA | 1 μA | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.5 |
500 mA | 1 μA | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.5 |
1 A | 10 μA | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.5 |
2 A | 10 μA | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.5 |
5 A | 10 μA | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.5 |
10 A | 100 μA | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.5 |
20 A | 100 μA | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.5 |
50 A | 100 μA | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.5 |
100 A | 1 mA | 0.01 | 0.005 | 200 + 50 | 60 + 40 | < 0.5 |
Measurement Type | Class 0.05 | Class 0.02 | |
Frequency | Measuring Range | 45 Hz~100 Hz | 45 Hz~100 Hz |
Minimum Resolution | 0.000 01 Hz | 0.000 01 Hz | |
Accuracy | ±0.005%*RD | ±0.005%*RD | |
Phase (I ≥ 50mA) |
Measuring Range | 0~360° | 0~360° |
Minimum Resolution | 0.000 1° | 0.000 1° | |
Accuracy | ±0.012° | ±0.006° |
Voltage Range | Current Range | Power Factor | Accuracy±(% of reading) | |
Class 0.05 | Class 0.02 | |||
30 V ≤ U ≤ 480 V | 50 mA ≤ I ≤120 A | 0.5L~1~0.5C | 0.05%*RD | 0.02%*RD |
10 mA ≤ I < 50 mA | 1 | 0.05%*RD | 0.02%*RD 0.04%*RD |
|
0.5L~1~0.5C | 0.08%*RD | |||
3 mA ≤ I < 10 mA | 1 | 0.08%*RD | 0.04%*RD | |
0.5L~1~0.5C | 0.15%*RD | 0.08%*RD | ||
0.2 mA ≤ I < 3 mA | 1 | 0.08%*RD×3mA/I | 0.04%*RD×3mA/I |
Power Supply | AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz | ||||
Warm Up Time | 30 min | ||||
Temperature Performance |
Storage temperature: 5°C~45°C Operating temperature: -10°C~55°C |
||||
Humidity Performance | Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C Storage humidity: (20%~80%) R·H, non-condensing |
||||
Elevation | < 3000 m | ||||
Communication Interface | RS232, RS485, LAN | ||||
Dimensions of Test Bench (L*W *table H / total H, mm) |
Position number | 3 test positions | 6 test positions | 12 test positions | 16 test positions |
Manual wiring | 1350*800*750/1140 | 1950*800*750/1140 | -- | -- | |
Crimping wiring | 1350*750*750/1395 | 1850*750*750/1395 | 1830*750*610/1765 | 2350*750*610/1765 | |
Dimensions of Computer Desk (L*W*H, mm) |
No Standard meter | 1000*800*750 | |||
Standard meter | 1500*800*750 |
Other Options | ||
Tick | Optional Function | Description |
Manual Wiring | The default option is Crimping wiring (with meter rack), Manual wiring is optional. | |
Offering Compatibility with both Single-phase and Three-phase | Up to 12 test positions | |
Current Transformer | Up to 12 test positions | |
Auxiliary Supply | AC/DC: 100V~240V, Up to 3 test positions | |
Power Consumption Test of Voltage Circuit | Up to 1 test position (proposal) | |
Power Consumption Test of Current Circuit: | Up to 3 test positions (proposal) | |
Burden Current Fast Change Test | Once selected, all test positions are supported; AC voltage dip and short interruption test. |
|
Fault Earthing Test | ||
Standard Meter | TD3300 Standard meter(Class 0.05 / 0.02) | |
Harmonic Energy | TD3300-R Standard meter(Class 0.05 / 0.02) |