TS1710 Surface Insulation Resistance Automatic Measuring System
for Electrical Steel
*Above picture is only for reference, subject to actual delivery
1. Summary
TS1710 is a special instrument for measuring the surface insulation resistance (single-sided) or interlayer resistance (double-sided) of electrical steel sheets. The reference standard is IEC60404-11.
2. Features
- Fully automatic feeding - turning over - testing - data uploading - unloading.
- Automatically measure five different test areas, the front and back sides do not overlap.
- 24 hours of uninterrupted operation.
- The conventional method is manual feeding, and AGV and other feeding methods can be customized.
- Guarantee personal safety, functional safety and information safety.
- Reliability, fault tolerance, upgradeability and easy maintenance.
- Data fusion and sharing, data comparability and consistency.
- Built-in precision DC stabilized power supply and precision DC current measurement unit.
- Equipped with standard resistance circuit board for daily verification of the system.
- An optional code reader can be used to automatically scan the code. (optional)
- Transparent shielding enclosure: to ensure the safety of operators, and to observe the internal test situation from outside.
- Warning light: green light when working normally, red light when abnormal state.
3. Specifications
3.1 Specifications of Electrical Parameters
Voltage Output Range |
DC,0 ~ 500 mV |
Current Measurement Range |
DC,0 ~ 1.2 A |
Uncertainty of Voltage and Current (k=2) |
0.1%*RG [1] |
Current Measurement Range of Copper Plate Test |
0.98 A ~ 1.02 A |
- Note: [1] RG is range;
|
3.2 Contact Actuator
Type |
Contact A (standard) |
Contact B (optional) |
Area of Single Contact |
64.5 × (1± 1%) mm2 |
100 × (1± 1%) mm2 |
Area of 10 Contacts |
645 × (1± 1%) mm2 |
1000 × (1± 1%) mm2 |
Total pressure of 10 Contacts |
1290 × ( 1 ± 5% ) N |
2000 × ( 1 ± 5% ) N |
Pressure Measurement Range |
0.01 ~ 5.00 N/mm2 |
Uncertainty of Pressure Measurement |
0.5% |
Pressurization Time |
within 20s per point |
4. Requirements of specimens
- Sample Size: ( 1000 mm~1200 mm ) × ( 100 mm ) (length×width)
- Sample Thickness: 0.1 mm~1.0 mm
- Other Requirements: The surface should be clean, flat, free from spots and scratches
5. General specifications
Power Supply |
AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz |
Temperature Performance |
Working Temperature:0°C~40°C; Storage Temperature:-20°C~70°C |
Humidity Performance |
Working Humidity:40%~80% R·H,No condensation Store Humidity:< 95% R·H,No condensation |
Air Supply |
- The compressed air pressure is not less than 0.6 MPa,and the air consumption is not less than 100 L/min
- The air source can be purchased with an air compressor or solved by yourself
|