• TD7600 Precision Process Calibrator
  • TD7600 Precision Process Calibrator
  • TD7600 Precision Process Calibrator
  • TD7600 Precision Process Calibrator
  • TD7600 Precision Process Calibrator
  • TD7600 Precision Process Calibrator

TD7600 Precision Process Calibrator

After-sales Service: Life Time
Warranty: 12 months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD7600 Precision Process Calibrator pictures & photos
TD7600 Precision Process Calibrator
US $36,700-45,700 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD7600
Customized
Non-Customized
DC voltage output/measurement
10 mV ~ 110 V
DC current output/measurement
0.1 mA ~110 mA
DC resistance simulation/measurement
4 Omega;~4.4 kOmega;
Voltage/current accuracy
class 0.03
Auxiliary power
24 V Loop mode power
Transport Package
Package for Exporting
Specification
20kg; 470 mm(W) x 470 mm(D) x 190 mm(H)
Trademark
TUNKIA
Origin
China

Packaging & Delivery

Package Size
55.00cm * 55.00cm * 25.00cm
Package Gross Weight
25.000kg

Product Description

TD7600 Precision Process Calibrator
TD7600 Precision Process Calibrator

1. Summary

TD7600 is a high-precision thermal meter and process signal meter calibrator. Applied to calibrate process signal calibrators, industrial sensors, transmitters etc.The accuracy of TD7600 can reach Class 0.003  and can calibrate the process signal calibrator of Class 0.01or below.

2. Features

  1. DC voltage output/measurement: 10 mV ~ 110 V;
  2. DC current output/measurement: 0.1 mA ~ 110 mA
  3. DC resistance simulation/measurement: 4 Ω~4.4 k Ω;
  4. Simulation and measurement of 11 types RTD and 12 types TC
  5. Voltage/current accuracy class: 0.003
  6. Auxiliary power supply: 24 V Loop mode power supply.
  7. Each power channel has good electrical isolation without mutual influence.
  8. Electrical protection.
  9. AC/DC analog output function (option)

3. Applications

TD7600 Precision Process Calibrator

4. Characteristics

Wide Output
TD7600 Precision Process Calibrator
  1. The capability of wide range output can cover most process calibrator.
 
Wide Input
TD7600 Precision Process Calibrator
  1. The capability of wide range input can cover most process calibrator.

Multiple Output Modes
TD7600 Precision Process Calibrator
  1. "Direct output"mode,User can set output value by physical key or touch screen.
TD7600 Precision Process Calibrator
  1. "Rotary Knob"mode,User can setting in clockwise direction or anticlockwise direction.



 

AC/DC Fitting Output (option)
TD7600 Precision Process Calibrator
  1. Supports DC+AC output mode, and the max AC output frequency is 5 kHz. Applied to calibrate turbine deflection.

5. Specifications

5.1 DC Voltage / Current

Range Resolution Output Measurement
Accuracy
±(ppm*reading+μV)
Max Burden Accuracy
±(ppm*reading+μV)
Input Resistance
100 mV 0.1 μV 25 + 2 10 mA 30 + 3 10 MΩ
1 V 1 μV 25 + 10 10 mA 30 + 10 10 MΩ
10 V 10 μV 25 + 100 10 mA 30 + 100 10 MΩ
100 V 0.1 mV 25 + 1000 5 mA 30 + 1000 10 MΩ
 
Range Resolution Output Measurement
Accuracy
±(ppm*reading+μA)
Max Burden Accuracy
±(ppm*reading+μA)
Input Resistance
1 mA 10 nA 30 + 0.02 12 V 30 + 0.02 50 Ω
5 mA 10 nA 30 + 0.1 12 V 30 + 0.1 50 Ω
20 mA 10 nA 30 + 0.4 12 V 30 + 0.4 50 Ω
100 mA 100 nA 30 + 2 12 V 30 + 2 10 Ω
  1. Voltage output/measurement: 10 mV~110 V, current output/measurement: 0.1 mA~110 mA
  2. Ripple coefficient:<0.1%
 

5.2 DC Resistance

Range Resolution Output Measurement
Accuracy
±(ppm*reading+mΩ)
Input current Accuracy
±(ppm*reading+mΩ)
Excitation Current
400 Ω 0.1 mΩ 20 + 7 1 mA~10 mA 20 + 4 1 mA
4000 Ω 1 mΩ 20 + 50 100 μA~1.2 mA 20 + 40 0.1 mA
  1. Resistance output: 4 Ω~440 Ω @ 400 Ω range; 5 Ω~4.4 k Ω @ 4 k Ω measuring range
  2. Measurement range of two-wire or four wire resistance: 4 Ω ~ 4.4 k Ω

5.3 Pulse Signal

Output/Measuring range Resolution Accuracy
1 Hz~1000 Hz 0.01 Hz ±0.005%
1 kHz~100 kHz 0.001 kHz ±0.005%
  1. Pulse signal output type: 0.3 V~12 VP-P level

5.4 RTD Output

Type Temperature Range (°C) Accuracy ( °C )
90 day( 23 ± 5 ) °C 1 year(3 ± 5 ) °C
Pt385, 25 Ω -200~850 ±0.20 ±0.25
Pt385, 100 Ω -200~850 ±0.04 ±0.05
Pt3926, 100 Ω -200~630 ±0.04 ±0.05
Pt3916, 100 Ω -200~630 ±0.04 ±0.05
Pt385, 200 Ω -200~320 ±0.30 ±0.35
320~850 ±0.35 ±0.40
Pt385, 500 Ω -200~-30 ±0.04 ±0.05
-30~850 ±0.13 ±0.15
Pt385, 1000 Ω -200~850 ±0.07 ±0.09
Cu427, 10 Ω -50~150 ±0.28 ±0.38
Cu50 Ω -50~150 ±0.07 ±0.09
Cu100 Ω -50~150 ±0.04 ±0.05
Ni120 Ω -80~260 ±0.018 ±0.02
 

5.5 RTD Measurement

Type Temperature Range (°C) Accuracy ( °C )
90 day( 23 ± 5 ) °C 1 year(3 ± 5 ) °C
Pt385, 25 Ω -200~850 ±0.25 ±0.30
Pt385, 100 Ω -200~80 ±0.012 ±0.013
80~200 ±0.021 ±0.022
200~400 ±0.024 ±0.025
400~850 ±0.035 ±0.038
Pt3916, 100 Ω -200~80 ±0.012 ±0.013
80~200 ±0.021 ±0.022
200~400 ±0.022 ±0.025
400~630 ±0.024 ±0.032
Pt3926, 100 Ω -200~80 ±0.012 ±0.013
80~200 ±0.020 ±0.021
200~400 ±0.022 ±0.025
400~630 ±0.030 ±0.031
Pt385, 200 Ω -200~100 ±0.015 ±0.02
100~320 ±0.025 ±0.03
320~600 ±0.05 ±0.08
600~850 ±0.07 ±0.09
Pt385, 500 Ω -200~-40 ±0.01 ±0.01
-40~100 ±0.024 ±0.026
100~320 ±0.030 ±0.033
320~600 ±0.040 ±0.043
600~850 ±0.07 ±0.076
Pt385, 1000 Ω -200~-140 ±0.013 ±0.014
-140~300 ±0.020 ±0.022
300~600 ±0.024 ±0.026
600~850 ±0.031 ±0.033
Cu427, 10 Ω -50~150 ±0.09 ±0.10
Cu50 Ω -50~150 ±0.04 ±0.06
Cu100 Ω -50~150 ±0.028 ±0.03
Ni120 Ω -80~260 ±0.008 ±0.009
  1. Remarks: Above accuracy for four wire measurement

5.6 TC Output / Measurement

Type Temperature Range (°C) Accuracy ( °C )
90 day( 23 ± 5 ) °C 1 year(3 ± 5 ) °C
B 410~600 ±0.33 ±0.35
600~900 ±0.26 ±0.28
900~1800 ±0.20 ±0.22
E -200~0 ±0.09 ±0.10
0~600 ±0.06 ±0.08
600~1000 ±0.08 ±0.10
J -200~-100 ±0.12 ±0.13
-100~750 ±0.07 ±0.08
750~1200 ±0.08 ±0.10
K -200~-100 ±0.15 ±0.16
-100~1000 ±0.08 ±0.10
1000~1370 ±0.10 ±0.12
N -200~-100 ±0.21 ±0.22
-100~400 ±0.07 ±0.09
400~1300 ±0.09 ±0.11
R -50~50 ±0.36 ±0.38
50~300 ±0.25 ±0.27
300~1000 ±0.18 ±0.20
1000~1750 ±0.18 ±0.20
S -50~50 ±0.36 ±0.38
50~300 ±0.25 ±0.27
300~1000 ±0.18 ±0.20
1000~1750 ±0.21 ±0.23
T -200~-100 ±0.13 ±0.15
-100~0 ±0.08 ±0.11
0~400 ±0.06 ±0.08
G 0~200 ±1.8 ±2.0
200~500 ±0.28 ±0.30
500~2300 ±0.23 ±0.25
C 0~800 ±0.13 ±0.14
800~2000 ±0.22 ±0.23
2000~2300 ±0.30 ±0.31
D 0~200 ±0.28 ±0.30
200~500 ±0.18 ±0.20
500~1900 ±0.23 ±0.25
1900~2300 ±0.33 ±0.35
  1. Output/measurement: -10 mV~80 mV
  2. Accuracy: (25 ppm+2 μ V )
  3. Display digits: 7-digit decimal display
  4. Ripple coefficient:<0.5%
  5. Remarks: with external compensation, S, R, B, K, N, E, J, T type accord to ITS-90 international temperature standard, G type accord to ASTM standard, C, D type accord to ZBN05003-88

6. General Specifications

Power Supply AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
Temperature Performance Working temperature:0°C~45°C;
Storage temperature:-20°C~70°C
Humidity Performance Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C
Storage humidity:(20%~80%) R·H,non-condensing
Interface RS232
 

7. Ordering Information

TD7600 Precision Process Calibrator
Company Profile
 

TD7600 Precision Process Calibrator

TD7600 Precision Process CalibratorTD7600 Precision Process Calibrator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD7600 Precision Process Calibrator pictures & photos
TD7600 Precision Process Calibrator
US $36,700-45,700 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013