• TD4200 Three-phase and DC Meters Test Equipment
  • TD4200 Three-phase and DC Meters Test Equipment
  • TD4200 Three-phase and DC Meters Test Equipment
  • TD4200 Three-phase and DC Meters Test Equipment
  • TD4200 Three-phase and DC Meters Test Equipment
  • TD4200 Three-phase and DC Meters Test Equipment

TD4200 Three-phase and DC Meters Test Equipment

Application: Electromagnetic Instrument
Power: Electricity
Customized: Non-Customized
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD4200 Three-phase and DC Meters Test Equipment pictures & photos
TD4200 Three-phase and DC Meters Test Equipment
US $90,800-155,400 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD4200
Accuracy class
0.01, 0.02
3PH voltage output
0.3 V~825 V
3PH AC current output
2 mA~110 A
Frequency
45 Hz~70 Hz
DC voltage output
5 mV~1100 V
Transport Package
Package for Exporting
Specification
2750 mm(W) x 900 mm(D) x 1090 mm(H)
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
300.00cm * 100.00cm * 150.00cm
Package Gross Weight
90.000kg

Product Description

TD4200 Testing DeviceDevice for Three-phase and DC Meters
TD4200 Three-phase and DC Meters Test Equipment

1.Summary
TD4200 is a multi-function comprehensive test-bed for the calibration of electrical measuring instruments. It integrates precision 3PH standard source, high-precision 3PH standard meter, precision DC standard source, test-bed, computer and special software. Can be used to calibrate three-phase AC/DC meter, AC standard source, AC/DC transmitter, etc.

2. Features

  1. Accuracy class: 0.01, 0.02;
  2. 3PH voltage output:0.3 V~825 V;
  3. 3PH current output:0.3 mA~110 A;
  4. 3PH standard meter (option): Tunkia TD33 series three-phase multi-function standard meter; (Note: also support COM3003,RD33,K2006, etc.)
  5. DC power output (option): 1100 V / 33A or 110A;
  6. Frequency and phase adjustable;
  7. Harmonic function / AC energy meter test function;
  8. Test software.

3. Applications

TD4200 Three-phase and DC Meters Test Equipment

 
 Calibrate Meters or Sources
TD4200 Three-phase and DC Meters Test Equipment
  1. 3PH voltage output: 0.3 V~825 V @ 45 Hz~70 Hz.
  2. 3PH current output: 0.3 mA~110 A @ 45 Hz~70 Hz.
  3. 3PH power output: voltage and current combination.
  4. DC voltage output: 5 mV~1100 V (option).
  5. DC current output: 10 μA~110 A (option).
  6. DC power output (option): voltage and current combination.
  7. Applied to the calibration of AC/DC voltage and current meter, active power meter, DC power meter, reactive power meter, volt-ampere meter and power factor meter.
  8. TD33 series standard meter (option): the best accuracy of measurement for 3PH power and electrical energy could reach 100 ppm; Applied to the calibration of single-phase or three-phase power standard source.


 

4. Characteristics

 Wide Output
TD4200 Three-phase and DC Meters Test Equipment
  1. It can meet most single-phase / three-phase meters or DC meters. 
 
 Wide Input (TD33 series option)
TD4200 Three-phase and DC Meters Test Equipment
  1. It can meet most single-phase / three-phase meters or DC source. 


 
 Multiple Output Mode
TD4200 Three-phase and DC Meters Test Equipment
  1. "Direct output"mode,User can set output value by physical key or touch screen.
  2. Three-phase unit adjustment or single phase adjustment.
TD4200 Three-phase and DC Meters Test Equipment
  1. "Rotary Knob"mode,User can setting in clockwise direction or anticlockwise direction.


 
 Multiple Output Mode
 TD4200 Three-phase and DC Meters Test Equipment
  1. Touch "Calibration point"of screen for "% setting".


 
 Testing Software(Option)
TD4200 Three-phase and DC Meters Test Equipment
  1. RS232 communication interface,software customizable.

5. Specifications

5.1 Three-Phase Power Source

5.1.1 Three-Phase Voltage Output

Voltage Range Resolution Stability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (mA)
Class 0.02 Class 0.01 Class 0.02 Class 0.01
3 V 0.01 mV 0.005 0.003 120 + 80 60 + 40 500 mA
10 V 0.1 mV 0.005 0.003 120 + 80 60 + 40 500 mA
30 V 0.1 mV 0.005 0.003 120 + 80 60 + 40 500 mA
100 V 0.1 mV 0.005 0.003 120 + 80 60 + 40 350 mA
300 V 1 mV 0.005 0.003 120 + 80 60 + 40 120 mA
600 V 1 mV 0.005 0.003 120 + 80 60 + 40 50 mA
750 V 10 mV 0.005 0.003 120 + 80 60 + 40 40 mA
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%).
  1. Output range: 0.3 V~825 V, distortion: < 0.2%;
  2. Short circuit and overload protection.

5.1.2 Three-Phase Current Output

Current Range Resolution Stability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (V)
Class 0.02 Class 0.01 Class 0.02 Class 0.01
3 mA 0.01 μA 0.005 0.003 120 + 80 60 + 40 50 V
10 mA 0.1 μA 0.005 0.003 120 + 80 60 + 40 50 V
30 mA 0.1 μA 0.005 0.003 120 + 80 60 + 40 50 V
100 mA 1 μA 0.005 0.003 120 + 80 60 + 40 50 V
300 mA 1 μA 0.005 0.003 120 + 80 60 + 40 50 V
1 A 10 μA 0.005 0.003 120 + 80 60 + 40 50 V
3 A 10 μA 0.005 0.003 120 + 80 60 + 40 30 V
10 A 0.1 mA 0.005 0.003 120 + 80 60 + 40 6 V
30 A 0.1 mA 0.005 0.003 120 + 80 60 + 40 2.5 V
100 A 1 mA 0.005 0.003 120 + 80 60 + 40 1.2 V
  1. Output range: 0.3 mA~110 A, distortion: < 0.2%;
  2. Open circuit and overload protection.

5.1.3 Frequency/Phase/Harmonic

Symmetry Voltage superior to 0.2%; Current superior to 0.5%; Phase superior to 0.5°
Frequency Range:45 Hz~70 Hz;
Adjustment fineness:0.001 Hz;
Accuracy:±0.01Hz (class 0.02), ±0.005Hz (class 0.01).
Phase Range:0.000 0°~359.999 9°;
Adjustment fineness:0.001°;
Accuracy:±0.01° (class 0.02), ±0.005° (class 0.01).
Harmonic 2nd~21st harmonic;
Amplitude 0~25% adjustable;
Phase 0~359.99°adjustable

5.1.4 Three-Phase Power Output

Type Current range Stability
( %/min )
Accuracy
( ± %*FS)[2]
Class 0.02 Class 0.01 Class 0.02 Class 0.01
active power |cosφ| ≥ 0.5 100 mA…100 A 0.01 0.005 0.02 0.01
10 mA…50 mA 0.01 0.005 0.05 0.02
reactive power   |sinφ| ≥ 0.5 100 mA…100 A 0.01 0.005 0.05 0.02
10 mA…50 mA 0.02 0.01 0.1 0.05
apparent power 100 mA…100 A 0.01 0.005 0.05 0.02
10 mA…50 mA 0.02 0.01 0.1 0.05
power factor 100 mA…100 A 0.01 0.005 0.05 0.02
10 mA…50 mA 0.02 0.01 0.1 0.05
Note [2] :FS= voltage range ×current range
  1. Range of power factor: -1.000 000…0.000 000…1.000 000.

5.2 Three-Phase Standard Meter (option, TD33 series)

5.2.1 Three-Phase Voltage Input

Range Resolution Accuracy
±(ppm of reading + ppm of range) [1]
Temperature Coefficient        @ (15~30)°C
(ppm*RD+ppm*RG) /°C
Class 0.02 Class 0.01 Class 0.02 Class 0.01
60 V 10 μV 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
120 V 0.1mV 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
240 V 0.1mV 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
480 V 0.1mV 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
  1. Measuring range: 6 V~528 V (support customized wider range), 7 digit display, manual / automatic range.
 

5.2.2 Three-Phase Current Input

Range Resolution Accuracy
±(ppm of reading + ppm of range) [1]
Temperature Coefficient        @ (15~30)°C
(ppm*RD+ppm*RG) /°C
Class 0.02 Class 0.01 Class 0.02 Class 0.01
5 mA 1 nA 240 + 160 120 + 80 10 + 10 5 + 5
10 mA 10 nA 120 + 80 60 + 40 5 + 5 3 + 3
20 mA 10 nA 120 + 80 60 + 40 1.25 + 1.25 0.75 + 0.75
50 mA 10 nA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
100 mA 0.1 μA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
200 mA 0.1 μA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
500 mA 0.1 μA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
1 A 1 μA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
2 A 1 μA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
5 A 1 μA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
10 A 10 μA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
20 A 10 μA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
50 A 10 μA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
100 A 100 μA 60 + 40 30 + 20 0.5 + 0.5 0.25 + 0.25
  1. Measuring range: 0.2 mA~120 A, 7 digit display, manual / automatic range.
 

5.2.3 Frequency / Phase

Type Class 0.02 Class 0.01
Frequency Range 45 Hz~65 Hz 45 Hz~65 Hz
Resolution 0.000 01 Hz 0.000 01 Hz
Accuracy ± 0.005%*RD ± 0.005%*RD
Phase Range 0~360°(I ≥ 50mA) 0~360°(I ≥ 50mA)
Resolution 0.000 1° 0.000 1°
Accuracy ± 0.006° ± 0.003°
 

5.2.4 Three-Phase Power Input

Voltage Range Current Range Power Factor Accuracy
Class 0.02 Class 0.01
30 V ≤ U ≤ 480 V 50 mA ≤ I ≤120 A 0.5L~1~0.5C ± 0.02%*reading ± 0.01%* reading
10 mA ≤ I < 50 mA 1 ± 0.02%* reading ± 0.01%* reading
0.5L~1~0.5C ± 0.04%* reading ± 0.02%* reading
3 mA ≤ I < 10 mA 1 ± 0.04%* reading ± 0.02%* reading
0.5L~1~0.5C ± 0.08%* reading ± 0.04%* reading
0.2 mA ≤ I < 3 mA 1 ± 0.04%*reading
×3mA/I
± 0.02%*reading
×3mA/I
  1. Power / electrical energy input range: combine AC voltage range and AC current range;
  2. Power factor input range: -1.000 000…0.000 000…1.000 000;
  3. Output pulse of standard electrical energy: at full scale, the high frequency correspond to 60 kHz and low frequency correspond to 6 Hz;
  4. Input pulse of standard electrical energy: frequency≤ 200 kHz, voltage: 0…3.3 V…24 V.
 

5.3 DC Power Source (option)

5.3.1 DC Voltage Output

Voltage Range Resolution Stability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (mA)
Class 0.02 Class 0.01 Class 0.02 Class 0.01
10 mV 0.1 μV 0.005 0.003 100 + 5 μV 100 + 5 μV 100 mA
30 mV 0.1 μV 0.005 0.003 100 + 5 μV 100 + 5 μV 100 mA
100 mV 1 μV 0.005 0.003 100 + 5 μV 100 + 5 μV 100 mA
300 mV 1 μV 0.005 0.003 100 + 5 μV 100 + 5 μV 100 mA
1 V 10 μV 0.005 0.002 100 + 50 60 + 40 500 mA
3 V 10 μV 0.005 0.002 100 + 50 60 + 40 500 mA
10 V 0.1 mV 0.005 0.002 100 + 50 60 + 40 500 mA
30 V 0.1 mV 0.005 0.002 120 + 80 60 + 40 800 mA
100 V 1 mV 0.005 0.002 120 + 80 60 + 40 300 mA
300 V 1 mV 0.005 0.002 120 + 80 60 + 40 100 mA
600 V 10 mV 0.005 0.002 120 + 80 60 + 40 50 mA
1000 V 10 mV 0.005 0.002 120 + 80 60 + 40 30 mA
  1. DC voltage output: 1 mV~1100 V, ripple ratio: < 1%;
  2. Short circuit and overload protection.
 

5.3.2 DC Current Output

Current Range Resolution Stability
( %/min )
Accuracy
±(ppm of reading + ppm of range) [1]
Max
Burden (V)
Class 0.02 Class 0.01 Class 0.02 Class 0.01
10 μA 0.1 nA 0.01 0.01 300 + 200 300 + 200 11 V
30 μA 0.1 nA 0.005 0.005 120 + 80 120 + 80 11 V
100 μA 1 nA 0.005 0.005 120 + 80 120 + 80 11 V
300 μA 1 nA 0.005 0.005 120 + 80 120 + 80 11 V
1 mA 10 nA 0.005 0.003 120 + 80 100 + 50 11 V
3 mA 10 nA 0.005 0.003 120 + 80 100 + 50 11 V
10 mA 0.1 μA 0.005 0.003 120 + 80 100 + 50 11 V
30 mA 0.1 μA 0.005 0.003 120 + 80 100 + 50 11 V
100 mA 1 μA 0.005 0.003 120 + 80 100 + 50 11 V
300 mA 1 μA 0.005 0.002 120 + 80 60 + 40 11 V
1 A 10 μA 0.005 0.002 120 + 80 60 + 40 11 V
3 A 10 μA 0.005 0.002 120 + 80 60 + 40 4 V
10 A 100 μA 0.005 0.002 120 + 80 60 + 40 4 V
30 A3 100 μA 0.005 0.002 120 + 80 60 + 40 3 V
100 A3 1 mA 0.005 0.002 120 + 80 60 + 40 3 V
  1. DC current output: 1 μA~33 A or 100 A optional, ripple ratio: < 1%;
  2. Open circuit and overload protection.
 

5.3.3 DC Power Output

DC power output Range Combine DC voltage and current range
Accuracy Addition of voltage and current accuracy.
 

5.3.4 DC Meter (Transmitter)

Range Measuring Range Accuracy Ripple Measuring Range Ripple Accuracy
1 V ± ( 0~1.2 ) V ± 0.01%*range 0~30 mV ± 1 mV
10 V ± ( 0~12 ) V ± 0.01%* range 0~300 mV ± 10 mV
2 mA ±( 0~2.4) mA ± 0.01%* range 0~60 μA ± 2 μA
20 mA ± ( 0~24 ) mA ± 0.01%* range 0~600 μA ± 20 μA
  1. Response time: range: 0~1000 ms, accuracy: ±40 ms.

6. General Specifications

Power Supply AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
Temperature Performance Working temperature:0°C~45°C;
Storage temperature:-20°C~70°C
Humidity Performance Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C
Storage humidity:(20%~80%) R·H,non-condensing
Interface RS232
 

7. Ordering Information

TD4200 Three-phase and DC Meters Test Equipment
Company Profile
 

TD4200 Three-phase and DC Meters Test Equipment

TD4200 Three-phase and DC Meters Test Equipment


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD4200 Three-phase and DC Meters Test Equipment pictures & photos
TD4200 Three-phase and DC Meters Test Equipment
US $90,800-155,400 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013