Voltage Range | Resolution | Stability ( %/min ) |
Accuracy ±(ppm of reading + ppm of range) [1] |
Max Burden (mA) |
||
Class 0.02 | Class 0.01 | Class 0.02 | Class 0.01 | |||
3 V | 0.01 mV | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 500 mA |
10 V | 0.1 mV | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 500 mA |
30 V | 0.1 mV | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 500 mA |
100 V | 0.1 mV | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 350 mA |
300 V | 1 mV | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 120 mA |
600 V | 1 mV | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 50 mA |
750 V | 10 mV | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 40 mA |
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%). |
Current Range | Resolution | Stability ( %/min ) |
Accuracy ±(ppm of reading + ppm of range) [1] |
Max Burden (V) |
||
Class 0.02 | Class 0.01 | Class 0.02 | Class 0.01 | |||
3 mA | 0.01 μA | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 50 V |
10 mA | 0.1 μA | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 50 V |
30 mA | 0.1 μA | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 50 V |
100 mA | 1 μA | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 50 V |
300 mA | 1 μA | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 50 V |
1 A | 10 μA | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 50 V |
3 A | 10 μA | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 30 V |
10 A | 0.1 mA | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 6 V |
30 A | 0.1 mA | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 2.5 V |
100 A | 1 mA | 0.005 | 0.003 | 120 + 80 | 60 + 40 | 1.2 V |
Symmetry | Voltage superior to 0.2%; Current superior to 0.5%; Phase superior to 0.5° |
Frequency | Range:45 Hz~70 Hz; Adjustment fineness:0.001 Hz; Accuracy:±0.01Hz (class 0.02), ±0.005Hz (class 0.01). |
Phase | Range:0.000 0°~359.999 9°; Adjustment fineness:0.001°; Accuracy:±0.01° (class 0.02), ±0.005° (class 0.01). |
Harmonic | 2nd~21st harmonic; Amplitude 0~25% adjustable; Phase 0~359.99°adjustable |
Type | Current range | Stability ( %/min ) |
Accuracy ( ± %*FS)[2] |
||
Class 0.02 | Class 0.01 | Class 0.02 | Class 0.01 | ||
active power |cosφ| ≥ 0.5 | 100 mA…100 A | 0.01 | 0.005 | 0.02 | 0.01 |
10 mA…50 mA | 0.01 | 0.005 | 0.05 | 0.02 | |
reactive power |sinφ| ≥ 0.5 | 100 mA…100 A | 0.01 | 0.005 | 0.05 | 0.02 |
10 mA…50 mA | 0.02 | 0.01 | 0.1 | 0.05 | |
apparent power | 100 mA…100 A | 0.01 | 0.005 | 0.05 | 0.02 |
10 mA…50 mA | 0.02 | 0.01 | 0.1 | 0.05 | |
power factor | 100 mA…100 A | 0.01 | 0.005 | 0.05 | 0.02 |
10 mA…50 mA | 0.02 | 0.01 | 0.1 | 0.05 | |
Note [2] :FS= voltage range ×current range |
Range | Resolution | Accuracy ±(ppm of reading + ppm of range) [1] |
Temperature Coefficient @ (15~30)°C (ppm*RD+ppm*RG) /°C |
||
Class 0.02 | Class 0.01 | Class 0.02 | Class 0.01 | ||
60 V | 10 μV | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
120 V | 0.1mV | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
240 V | 0.1mV | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
480 V | 0.1mV | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
Range | Resolution | Accuracy ±(ppm of reading + ppm of range) [1] |
Temperature Coefficient @ (15~30)°C (ppm*RD+ppm*RG) /°C |
||
Class 0.02 | Class 0.01 | Class 0.02 | Class 0.01 | ||
5 mA | 1 nA | 240 + 160 | 120 + 80 | 10 + 10 | 5 + 5 |
10 mA | 10 nA | 120 + 80 | 60 + 40 | 5 + 5 | 3 + 3 |
20 mA | 10 nA | 120 + 80 | 60 + 40 | 1.25 + 1.25 | 0.75 + 0.75 |
50 mA | 10 nA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
100 mA | 0.1 μA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
200 mA | 0.1 μA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
500 mA | 0.1 μA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
1 A | 1 μA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
2 A | 1 μA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
5 A | 1 μA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
10 A | 10 μA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
20 A | 10 μA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
50 A | 10 μA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
100 A | 100 μA | 60 + 40 | 30 + 20 | 0.5 + 0.5 | 0.25 + 0.25 |
Type | Class 0.02 | Class 0.01 | |
Frequency | Range | 45 Hz~65 Hz | 45 Hz~65 Hz |
Resolution | 0.000 01 Hz | 0.000 01 Hz | |
Accuracy | ± 0.005%*RD | ± 0.005%*RD | |
Phase | Range | 0~360°(I ≥ 50mA) | 0~360°(I ≥ 50mA) |
Resolution | 0.000 1° | 0.000 1° | |
Accuracy | ± 0.006° | ± 0.003° |
Voltage Range | Current Range | Power Factor | Accuracy | |
Class 0.02 | Class 0.01 | |||
30 V ≤ U ≤ 480 V | 50 mA ≤ I ≤120 A | 0.5L~1~0.5C | ± 0.02%*reading | ± 0.01%* reading |
10 mA ≤ I < 50 mA | 1 | ± 0.02%* reading | ± 0.01%* reading | |
0.5L~1~0.5C | ± 0.04%* reading | ± 0.02%* reading | ||
3 mA ≤ I < 10 mA | 1 | ± 0.04%* reading | ± 0.02%* reading | |
0.5L~1~0.5C | ± 0.08%* reading | ± 0.04%* reading | ||
0.2 mA ≤ I < 3 mA | 1 | ± 0.04%*reading ×3mA/I |
± 0.02%*reading ×3mA/I |
Voltage Range | Resolution | Stability ( %/min ) |
Accuracy ±(ppm of reading + ppm of range) [1] |
Max Burden (mA) |
||
Class 0.02 | Class 0.01 | Class 0.02 | Class 0.01 | |||
10 mV | 0.1 μV | 0.005 | 0.003 | 100 + 5 μV | 100 + 5 μV | 100 mA |
30 mV | 0.1 μV | 0.005 | 0.003 | 100 + 5 μV | 100 + 5 μV | 100 mA |
100 mV | 1 μV | 0.005 | 0.003 | 100 + 5 μV | 100 + 5 μV | 100 mA |
300 mV | 1 μV | 0.005 | 0.003 | 100 + 5 μV | 100 + 5 μV | 100 mA |
1 V | 10 μV | 0.005 | 0.002 | 100 + 50 | 60 + 40 | 500 mA |
3 V | 10 μV | 0.005 | 0.002 | 100 + 50 | 60 + 40 | 500 mA |
10 V | 0.1 mV | 0.005 | 0.002 | 100 + 50 | 60 + 40 | 500 mA |
30 V | 0.1 mV | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 800 mA |
100 V | 1 mV | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 300 mA |
300 V | 1 mV | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 100 mA |
600 V | 10 mV | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 50 mA |
1000 V | 10 mV | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 30 mA |
Current Range | Resolution | Stability ( %/min ) |
Accuracy ±(ppm of reading + ppm of range) [1] |
Max Burden (V) |
||
Class 0.02 | Class 0.01 | Class 0.02 | Class 0.01 | |||
10 μA | 0.1 nA | 0.01 | 0.01 | 300 + 200 | 300 + 200 | 11 V |
30 μA | 0.1 nA | 0.005 | 0.005 | 120 + 80 | 120 + 80 | 11 V |
100 μA | 1 nA | 0.005 | 0.005 | 120 + 80 | 120 + 80 | 11 V |
300 μA | 1 nA | 0.005 | 0.005 | 120 + 80 | 120 + 80 | 11 V |
1 mA | 10 nA | 0.005 | 0.003 | 120 + 80 | 100 + 50 | 11 V |
3 mA | 10 nA | 0.005 | 0.003 | 120 + 80 | 100 + 50 | 11 V |
10 mA | 0.1 μA | 0.005 | 0.003 | 120 + 80 | 100 + 50 | 11 V |
30 mA | 0.1 μA | 0.005 | 0.003 | 120 + 80 | 100 + 50 | 11 V |
100 mA | 1 μA | 0.005 | 0.003 | 120 + 80 | 100 + 50 | 11 V |
300 mA | 1 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 11 V |
1 A | 10 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 11 V |
3 A | 10 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 4 V |
10 A | 100 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 4 V |
30 A3 | 100 μA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 3 V |
100 A3 | 1 mA | 0.005 | 0.002 | 120 + 80 | 60 + 40 | 3 V |
DC power output | Range | Combine DC voltage and current range |
Accuracy | Addition of voltage and current accuracy. |
Range | Measuring Range | Accuracy | Ripple Measuring Range | Ripple Accuracy |
1 V | ± ( 0~1.2 ) V | ± 0.01%*range | 0~30 mV | ± 1 mV |
10 V | ± ( 0~12 ) V | ± 0.01%* range | 0~300 mV | ± 10 mV |
2 mA | ±( 0~2.4) mA | ± 0.01%* range | 0~60 μA | ± 2 μA |
20 mA | ± ( 0~24 ) mA | ± 0.01%* range | 0~600 μA | ± 20 μA |
Power Supply | AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz |
Temperature Performance | Working temperature:0°C~45°C; Storage temperature:-20°C~70°C |
Humidity Performance | Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C Storage humidity:(20%~80%) R·H,non-condensing |
Interface | RS232 |