TD1855 Multifunction Calibrator with AC/DC Power Output

Tunkia Co., Ltd.
  • Audited Supplier
  • 6 yrs

Contact Supplier

Product Highlights

  • High Precision Accuracy: Class 0.05 accuracy for reliable calibration of electrical instruments.
  • Multi-Function Output: Integrates AC/DC voltage, current, resistance, frequency, and power output.
  • Optional 33A Current: DC and AC current output extends to 33 Amperes as an optional configuration.
  • LCD Touch Interface: Features an LCD touch screen for direct value setting and operation.
  • Comprehensive Calibration: Calibrates multimeters, power meters, clamp meters, and transducers.
  • Remote Adjustment: Supports remote box for coarse and fine adjustment of voltage and current.
  • Wide Frequency Range: Sinusoidal wave output from 45 Hz to 1100 Hz with 2 MHz square wave option.
  • Lifetime After-Sales: Provides lifetime after-sales service with a 12-month warranty on the unit.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of TD1855 Multifunction Calibrator with AC/DC Power Output

TD1855 Multifunction Calibrator with AC/DC Power Output
TD1855 Multifunction Calibrator with AC/DC Power Output pictures & photos
TD1855 Multifunction Calibrator with AC/DC Power Output
TD1855 Multifunction Calibrator with AC/DC Power Output pictures & photos
TD1855 Multifunction Calibrator with AC/DC Power Output
TD1855 Multifunction Calibrator with AC/DC Power Output pictures & photos
TD1855 Multifunction Calibrator with AC/DC Power Output
TD1855 Multifunction Calibrator with AC/DC Power Output pictures & photos
TD1855 Multifunction Calibrator with AC/DC Power Output
TD1855 Multifunction Calibrator with AC/DC Power Output pictures & photos
TD1855 Multifunction Calibrator with AC/DC Power Output
TD1855 Multifunction Calibrator with AC/DC Power Output pictures & photos
TD1855 Multifunction Calibrator with AC/DC Power Output
  • TD1855 Multifunction Calibrator with AC/DC Power Output
  • TD1855 Multifunction Calibrator with AC/DC Power Output
    TD1855 Multifunction Calibrator with AC/DC Power Output
  • TD1855 Multifunction Calibrator with AC/DC Power Output
    TD1855 Multifunction Calibrator with AC/DC Power Output
  • TD1855 Multifunction Calibrator with AC/DC Power Output
    TD1855 Multifunction Calibrator with AC/DC Power Output
  • TD1855 Multifunction Calibrator with AC/DC Power Output
    TD1855 Multifunction Calibrator with AC/DC Power Output
  • TD1855 Multifunction Calibrator with AC/DC Power Output
    TD1855 Multifunction Calibrator with AC/DC Power Output
  • TD1855 Multifunction Calibrator with AC/DC Power Output
    TD1855 Multifunction Calibrator with AC/DC Power Output

Find Similar Products

Product Description

TD1855 Multi-function Calibrator
TD1855 Multifunction Calibrator with AC/DC Power Output
Summary

 

TD1855 is a multi-function calibrator, integrates AC\DC voltage source, AC\DC current source, DC resistance source, etc. The accuracy class is 0.05. It's applied to calibrating 3.5 digits multimeter, voltmeter, ammeter, ohmmeter, power meter.
Features

 

DC voltage output: 20 mV ~ 1100 V
DC current output: 2 μA ~ 22 A(33 A is optional)
AC voltage output: 20 mV ~ 1100 V
AC current output: 200 μA ~ 22 A(33 A is optional)
Sinusoidal wave frequency: 45 Hz ~ 1100 Hz
Simulated DC resistance: 10 Ω ~ 220 MΩ
2 MHz square wave frequency output
Phase output
AC/DC power output
Remote adjustment (optional) 
Clamp meter calibration (optional)
Transducer calibration(optional)  
Application

 


TD1855 Multifunction Calibrator with AC/DC Power Output 

☆ Calibrate AC\DC electrical measuring instruments
TD1855 Multifunction Calibrator with AC/DC Power Output
DCV output: 20 mV ~ 1100 V
DCI output: 2 μA ~ 22 A\33 A
ACV output: 20 mV ~ 1100 V, 45 Hz ~ 1100 Hz
ACI output: 200 μA ~ 22 A\33 A, 45 Hz ~ 1100 Hz
RES output: 10 Ω ~ 220 MΩ
Frequency output: 1 Hz ~ 2 MHz
Calibrate digital multimeter, AC/DC voltmeter, AC/DC ammeter, DC ohmmeter, frequency meter.
☆ Calibrate AC\DC power meters
TD1855 Multifunction Calibrator with AC/DC Power Output
Calibrate DC power meter, real power meter, phantom power meter, apparent power meter, power frequency phase meter and power factor meter.
 
☆ Calibrate clamp ammeter (optional)
TD1855 Multifunction Calibrator with AC/DC Power Output
Equivalent to 1000AT current through input 20A current to the 50T Coil, which is suitable for calibrating DC clamp meters.
 
☆ Calibrate AC/DC Transducer (optional)
TD1855 Multifunction Calibrator with AC/DC Power Output
DC small-signal measurement. (Vmax: 12 V, Imax: 24 mA)
Calibrate the proportional error of AC/DC voltage/current transducer.
 
Appearance

 

☆ Front\Side Panel
TD1855 Multifunction Calibrator with AC/DC Power Output
Item Description
1 LCD touch screen.
2 Operation panel.
3 Simulated DC resistance output terminals.
4 AC/DC voltage output terminals.
5 AC/DC current output terminals.
6 Handle: used for carrying instruments.
7 Input terminals for DC transducer. 
 
☆ Rear Panel
TD1855 Multifunction Calibrator with AC/DC Power Output
Item Description
1 Pulse frequency output terminals.
2 Remote box interface.
3 RS232 communication interface.
4 Chassis ground binding post.
5 AC 220V power interface.
6 Cooling vents.
 
Characteristics

 

 
☆ Multiple output\adjustment methods
TD1855 Multifunction Calibrator with AC/DC Power Output
"Direct output" mode: the value output can be set directly by physical key or touch screen.
TD1855 Multifunction Calibrator with AC/DC Power Output
Calibration of the analog pointer meter usually needs to test scale by scale, especially "differences between rising and falling" (the change caused by the rise and fall of the calibration point).
Remote box can realize the coarse and fine adjustment of current or voltage.
 
Specifications

 

6.1 DC Voltage/Current Output

Range Resolution Stability (±±%/min) Accuracy
±(ppm*RD+ppm*RG)[1]
Max burden (mA) Ripple Factor(%)
200 mV 1 μV 0.01 300 + 200 300 <0.5
2 V 10 μV 0.01 300 + 200 500 <0.5
10 V 100 μV 0.01 300 + 200 500 <0.5
30 V 100 μV 0.01 300 + 200 800 <0.5
100 V 1 mV 0.01 300 + 200 300 <0.5
300 V 1 mV 0.01 300 + 200 100 <0.5
600 V 1 mV 0.01 300 + 200 50 <0.5
1000 V 10 mV 0.01 300 + 200 30 <0.5
 
Range Resolution Stability
(±±%/min)
Accuracy
 ±(ppm*RD+ppm*RG)
Compliance Voltage (V) Ripple Factor(%)
20μA 100pA 0.01 300 + 200 10 <0.5
200μA 1 nA 0.01 300 + 200 9 <0.5
2mA 10 nA 0.01 300 + 200 9 <0.5
20mA 100 nA 0.01 300 + 200 9 <0.5
200 mA 1 μA 0.01 300 + 200 9 <0.5
2 A 10 μA 0.01 300 + 200 3.5 <0.5
10 A 100 μA 0.01 300 + 200 2.5 <0.5
20 A (30 A)[2] 100 μA 0.01 300 + 200 2.5 <0.5
Note[1]: RD is the reading value, RG is the range value;
Note[2]: The 30 A range is optional.
  1. Voltage output range: 20 mV ~ 1100 V
  2. Current output range: 2 μA ~ 22 A\33 A
  3. Protections: voltage source short-circuit protection, current source open-circuit protection, overload protection

6.2 AC Voltage/Current Output

Range Resolution Stability
 (±±%/min)
Accuracy
 ±(ppm*RD+ppm*RG)
Max Burden (mA) Harmonic (%)
200 mV 1 μV 50 μV 300 + 60 μV 500 <1.0
2 V 10 μV 0.01 300 + 200 500 <0.5
10 V 100 μV 0.01 300 + 200 800 < 0.5
30 V 100 μV 0.01 300 + 200 800 < 0.5
100 V 1 mV 0.01 300 + 200 300 < 0.5
300 V 1 mV 0.01 300 + 200 100 < 0.5
600 V 1 mV 0.01 300 + 200 50 < 0.5
1000 V 10 mV 0.01 300 + 200 30 < 0.5
 
Range Resolution Stability
 (±±%/min)
Accuracy
 ±(ppm*RD+ppm*RG)
Compliance Voltage (V) Harmonic (%)
2 mA 10 nA 0.6 μA 300 +0.6 μA 50 <0.5
20 mA 100 nA 0.01 300 + 200 50 <0.5
200 mA 1 μA 0.01 300 + 200 50 <0.5
1 A 10 μA 0.01 300 + 200 15 <0.5
2 A 10 μA 0.01 300 + 200 10 <0.5
5 A 10 μA 0.01 300 + 200 5 <0.5
20 A(30 A)[1] 100 μA 0.01 300 + 200 2.5 <0.5
Note [1]: 30 A range is optional.
  1. Voltage output range: 20 mV ~ 1100 V
  2. Current output range: 200 μA ~ 22 A\33 A
  3. Voltage and current output frequency: 45 Hz ~ 1100 Hz
  4. Protections: voltage source short-circuit protection, current source open-circuit protection, overload protection

6.3 Simulated DC Resistance

Range Resolution Accuracy
 ±(ppm*RD+ppm*RG)
Allowable Current
100 Ω 1 mΩ 300 + 200 1mA~80 mA
300 Ω 1 mΩ 300 + 200 1mA~80 mA
1 kΩ 10 mΩ 300 + 200 100μA~8 mA
3kΩ 10 mΩ 300 + 200 100μA~8 mA
10 kΩ 100 mΩ 300 + 200 10μA~0.8 mA
30 kΩ 100 mΩ 300 + 200 10μA~0.8 mA
100 kΩ 1 Ω 300 + 200 10μA~0.8 mA
300 kΩ 1 Ω 300 + 200 1μA~80 μA
1 MΩ 10 Ω 300 + 200 1μA~80 μA
10 MΩ 100 Ω 600 + 400 100nA~8 μA
100 MΩ 1000 Ω 3000 + 2000 10nA~0.8 μA
200 MΩ 1000 Ω 3500 + 2500 10nA~0.8 μA
  1. Output range: 10 Ω ~ 220 MΩ
  2. Over-current and reverse connection protection

6.4 Sinusoidal Wave Frequency Output

Output Range[1] Resolution Accuracy
45.0000 Hz ≤ F ≤ 99.9999 Hz 0.0001 Hz ±0.01%
100.000 Hz ≤ F ≤ 999.999 Hz 0.001 Hz ±0.01%
1000.00 Hz ≤ F ≤ 1100.00 Hz 0.01 Hz ±0.01%
Note [1]: The output mode is AC voltage or AC current.
 

6.5 AC/DC Power Output

Frequency Range (f) Voltage Range (U) Current Range (I) Optimum Accuracy
%*power output [1][2]
DC 20 mV ~ 1100 V 2 μA ~ 22 A/33 A ±0.1
45 Hz ~ 65 Hz 3 V ~ 600 V 0.2 mA ~ 22 A/33 A ±0.1
 

6.6 Phase and Power Factor Output(45 Hz~65 Hz)

Phase Power Factor Accuracy
WATTS VARS λ=cosφ Phase Power Factor
0° 90° 1.0000 0.1° 0.000%
10° 80° 0.9848 0.1° 0.031%
20° 70° 0.9397 0.1° 0.064%
30° 60° 0.8660 0.1° 0.101%
40° 50° 0.7660 0.1° 0.147%
50° 40° 0.6429 0.1° 0.208%
60° 30° 0.5000 0.1° 0.302%
70° 30° 0.3420 0.1° 0.480%
80° 10° 0.1737 0.1° 0.990%
90° 0° 0.0000 0.1° -
Note [1]: Phase range: 0.000 ° ~ 359.999 °, fineness: 0.005 °
Note [2]: Power factor range: -1 ~ 0 ~ 1, fineness: 0.000 1
Note [3]: Calculation formulas for the accuracy of other power factor:
 

6.7 Pulse Frequency Output

Range[1] Resolution Accuracy Shake
1.000 00 Hz ≤ F ≤ 9.999 99 Hz 10 μHz ±(20 ppm*RD + 20 μHz) <20 ns
10.000 0 Hz ≤ F ≤ 99.999 9 Hz 0.1 mHz
100.000 Hz ≤ F ≤ 999.999 Hz 1 mHz
1.000 00 kHz ≤ F ≤ 9.999 99 kHz 10 mHz
10.000 0 kHz ≤ F ≤ 99.999 9 kHz 0.1 Hz
100.000 kHz ≤ F ≤ 999.999 kHz 1 Hz
1.000 00 MHz ≤ F ≤ 2.000 00 MHz
10 Hz
Note [1]: The output type is TTL level.
 

6.8 DC Small-signal Measurement (optional)

Type Range Range Accuracy
DCV 1 V ±(0~1.2) V ±(0.006%*RD + 0.004%*RG)
10 V ±(0~12) V ±(0.006%*RD + 0.004%*RG)
DCI 2 mA ±(0~2.4) mA ±(0.006%*RD + 0.004%*RG)
20 mA ±(0~24) mA ±(0.006%*RD + 0.004%*RG)
 
General Specifications

 

Power supply AC (220±22) V,(50±2) Hz
Maximum power consumption 600 VA
Warm up time Twice the time since last warmed up, to a maximum of 30 minutes.
Temperature performance Operating temperature: 0°C ~ 40°C
Calibration temperature: 18°C ~ 28°C
Storage temperature: -20°C ~ 70°C
Humidity performance Operating humidity: <80% @ 30°C,<70% @ 40°C
Storage humidity: (20%~80%) R·H,No condensation
Communication interface RS232
Dimensions 475 mm(W)× 400 mm (D) × 190 mm (H), excluding handles and feets.
Weight About 19.5 kg
 
Company Profile

TD1855 Multifunction Calibrator with AC/DC Power Output

TD1855 Multifunction Calibrator with AC/DC Power Output

 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI2191183". Items marked "verified" are certified.

Watch Video
Watch Video
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.
Tunkia Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory
Address
No. 16 Panpan Road, Changsha, Hunan, China
verified Plant Area
8000 square meters
verified Number of Employees
363
verified Registered Capital
25,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Changsha Port

Our Production Capability & Technical Expertise

verified Main Products
Magnetic Measurement, Electrical Measurement, Gaussmeter, Multifunction Calibrator
verified Production Machines
SMT Machine, Printing Machine, Assembly & Debugging Line, Automatic Online Function Test (EPS&SST)
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
120 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2006-06-16
Export Year
2021-10-11
verified Main Markets
Europe, Southeast Asia/ Mideast, East Asia(Japan/ South Korea), Domestic
verified Number of Foreign Trading Staff
2
verified Overseas Agent/Branch
No

FAQ

What is the accuracy class of the TD1855?
The TD1855 features a high precision accuracy class of 0.05.
What instruments can this calibrator test?
It is designed to calibrate 3.5 digits multimeters, voltmeters, ammeters, ohmmeters, power meters, clamp meters, and transducers.
Is the 33A current output standard or optional?
The standard current output is 22A, but 33A is available as an optional configuration for both DC and AC.
What is the warranty period for this device?
The device comes with a 12-month warranty and includes lifetime after-sales service.
Does the TD1855 support remote operation?
Yes, it supports remote adjustment via a remote box for coarse and fine tuning of voltage and current.
What are the voltage output ranges?
The DC and AC voltage output ranges are from 20 mV to 1100 V.
Does the product support OEM or ODM services?
Yes, the manufacturer offers both OEM and ODM services for this product.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now