• TD1050 Calibration Apparatus for Clamp Meters
  • TD1050 Calibration Apparatus for Clamp Meters
  • TD1050 Calibration Apparatus for Clamp Meters
  • TD1050 Calibration Apparatus for Clamp Meters
  • TD1050 Calibration Apparatus for Clamp Meters
  • TD1050 Calibration Apparatus for Clamp Meters

TD1050 Calibration Apparatus for Clamp Meters

After-sales Service: Life Time
Warranty: 12 Months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TD1050 Calibration Apparatus for Clamp Meters pictures & photos
TD1050 Calibration Apparatus for Clamp Meters
US $39,000-57,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD1050
Power
Electricity
Voltage Output
20 mV ~ 1100 V
Current Output
10 mA~ 1050 A
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
Class 0.05
DC current output
10 mA~ 1050 A, 2100 A optional
AC current output
10 mA ~ 1020 A, 2050 A is optional
DC voltage output(optional)
20 mV ~ 1100 V
AC voltage output(optional)
1 V ~ 825 V
Frequency
40 Hz ~ 400 Hz
DC resistance output(optional)
10 Ω ~ 110 MΩ
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
180.00cm * 200.00cm * 180.00cm
Package Gross Weight
90.000kg

Product Description

TD1050 Calibration Apparatus for Clamp Meters TD1050 Calibration Apparatus for Clamp Meters

1. Summary

TD1050 is a calibration apparatus for multifunctional clamp meters, which integrates functions such as AC/DC high current standard source, AC/DC voltage standard source, and resistance standard source, and also has AC/DC power output function, which can meet the calibration needs of multifunctional clamp meters with different accuracy levels.

2. Features

Accuracy: Class 0.05
DC current: 10 mA ~ 1050 A(2100 A is optional)
AC current output: 10 mA ~ 1020 A(2050 A is optional)
DC voltage output(optional): 20 mV ~ 1100 V
AC voltage output(optional): 1 V ~ 825 V
Frequency: 40 Hz ~ 400 Hz
DC resistance output(optional): 10 Ω ~ 11 MΩ
Two thickness copper rings
AC/DC power output(optional)

3. Application

TD1050 Calibration Apparatus for Clamp Meters

 
Calibrate Clamp Meter by Single-turn Method
TD1050 Calibration Apparatus for Clamp Meters
DCI output: 10 mA~1050 A(2100 A is optional)
ACI output: 10 mA~1020 A(2050 A is optional), 40 Hz ~ 400 Hz
Calibrate AC\DC clamp ammeters

Calibrate Clamp Power Meters(optional)
TD1050 Calibration Apparatus for Clamp Meters
  1. Integrates AC\DC current and voltage standard source, the U-I phase can be adjusted, which is suitable for calibrating clamp power meters.
 
Calibrate Multi-function Clamp Meters(optional)
TD1050 Calibration Apparatus for Clamp Meters
DCV output: 20 mV ~ 1100V
ACV output: 1 V ~ 825 V, 40 Hz ~ 400 Hz
RES output range: 10 Ω ~ 11 MΩ
Calibrate AC/DC voltmeter and DC resistance meter
 

4. Panel Features

TD1050 Calibration Apparatus for Clamp Meters
Item Description
1 Current Source, Output AC\DC current. 
2 Copper Ring 1, I110 A.
3 Copper Ring 2, I>100 A.
4 Workbench, used to settle the device.
5 Operate Panel, adjust electric parameter of the device.
6 Voltage Output terminals
7 Resistance Output terminals
8 Operate Panel terminal, connected to the control panel.
9 RS232 Interface,.
10 Power Switch
11 E-Stop, Used to stop the power supply in an emergency
 

5. Characteristics

Convenient Traceability
TD1050 Calibration Apparatus for Clamp Meters
  1. Calibrate the AC\DC current source through accessing the standard ammeter(TH0630 or TH0530)to the current loop.
 
 Wide Output Range
TD1050 Calibration Apparatus for Clamp Meters
 

6. Specifications

6.1 DC Current

Copper Ring Range Resolution Output Range Max Load
Ring 1 100 mA 1 μA 10.000 mA ~ 110.000 mA 8 V
300 mA 1 μA 30.000 mA ~ 330.000 mA 8 V
1 A 10 μA 0.10000 A ~ 1.10000 A 8 V
3 A 10 μA 0.30000 A ~ 3.30000 A 8 V
10 A 100 μA 1.0000 A ~ 11.0000 A 8 V
30 A 100 μA 3.0000 A ~ 33.0000 A 8 V
100 A 1 mA 10.000 A ~ 110.000 A 8 V
Ring 2 250 A 1 mA 20.000 A ~ 275.000 A 8 V
500 A 1 mA 50.000 A ~ 550.000 A 8 V
1000 A 10 mA 100.00 A ~ 1050.00 A 8 V
2000 A [1] 10 mA 200.00 A ~ 2100.00 A 8 V
Note[1]: 2000 A is Optional
 
Range Stability (±%/min) Accuracy, ±(ppm*RD+ppm*RG) [2] Ripple Factor (%)
100 mA 0.01 300 + 100 <0.5
300 mA 0.01 300 + 100 < 0.5
1 A 0.01 300 + 100 < 0.5
3 A 0.01 300 + 100 < 0.5
10 A 0.01 300 + 100 < 0.5
30 A 0.01 300 + 100 < 0.5
100 A 0.01 300 + 100 < 0.5
250 A 0.01 300 + 100 < 0.5
500 A 0.01 300 + 100 < 0.5
1000 A 0.01 300 + 100 < 0.5
2000 A 0.01 300 + 100 < 0.5
Note[2]: RD=Reading,RG=Range, unless otherwise noted;
 
  1. Output range: 10 mA ~ 1050 A\2100 A
  2. Manual or automatic range switch.
  3. Adjustment fineness: 0.002%*RG
  4. 6 digits decimal display
  5. Protections: open-circuit protection, overload protection, over-heat protection

6.2 AC Current

Copper Ring Range Resolution Output Range Frequency Max Compliance Voltage(rms)
Ring 1 100 mA 1 μA 10.000 mA ~ 110.000 mA 40 Hz ~ 400 Hz 6 V
300 mA 1 μA 30.000 mA ~ 330.000 mA 40 Hz ~ 400 Hz 6 V
1 A 10 μA 0.10000 A ~ 1.10000 A 40 Hz ~ 400 Hz 6 V
3 A 10 μA 0.30000 A ~ 3.30000 A 40 Hz ~ 400 Hz 6 V
10 A 100 μA 1.0000 A ~ 11.0000 A 40 Hz ~ 400 Hz 6 V
30 A 100 μA 3.0000 A ~ 33.0000 A 40 Hz ~ 400 Hz 6 V
100 A 1 mA 10.000 A ~ 110.000 A 40 Hz ~ 400 Hz 6 V
Ring 2 250 A 1 mA 20.000 A ~ 275.000 A 40 Hz ~ 400 Hz 6 V
500 A 1 mA 50.000 A ~ 550.000 A 40 Hz ~ 400 Hz 6 V
1000 A 10 mA 100.00 A ~ 1020.00 A 40 Hz ~ 400 Hz 6 V
2000 A [3] 10 mA 200.00 A ~ 2050.00 A 40 Hz ~ 400 Hz 6 V
 
Range Stability 
(±%/min)
Accuracy
 ±(ppm*RD+ppm*RG)
Distortion (%)
100 mA 0.01 300 + 100 <0.5
300 mA 0.01 300 + 100 <0.5
1 A 0.01 300 + 100 <0.5
3 A 0.01 300 + 100 <0.5
10 A 0.01 300 + 100 <0.5
30 A 0.01 300 + 100 <0.5
100 A 0.01 300 + 100 <0.5
250 A 0.01 300 + 100 <0.5
500 A 0.01 300 + 100 <0.5
1000 A 0.01 300 + 100 <0.5
2000 A [1] 0.01 300 + 100 <0.5
Note[3]: Range 2000 A is optional.
  1. Output range: 10 mA ~ 1020 A (2050 A)
  2. Frequency: 40 Hz ~ 400 Hz, adjustment fineness 0.001 Hz,accuracy ±0.01%.
  3. Adjustment fineness: 0.002%*RG
  4. 6 digits display
  5. Protections: open-circuit protection, overload protection, over-heat protection

6.3 DC Voltage(optional)

Range Resolution Output Range Max Burden
200 mV 1 μV 20.000 mV ~ 220.000 mV 100 mA
1 V 10 μV 0.10000 V ~ 1.00000 V 100 mA
10 V 100 μV 1.0000 V ~ 11.0000 V 100 mA
30 V 100 μV 3.0000 V ~ 33.0000 V 600 mA
100 V 1 mV 10.000 V ~ 110.000 V 200 mA
300 V 1 mV 30.000 V ~ 330.000 V 60 mA
600 V 1 mV 60.000 V ~ 660.000 V 25 mA
1000 V 10 mV 100.00 V ~ 1100.00 V 20 mA
 
Range Stability 
(±%/min)
Accuracy
 ±(ppm*RD+ppm*RG)
Ripple Factor (%)
200 mV 0.01 300 + 200 <0.5
1 V 0.01 300 + 200 < 0.5
10 V 0.01 300 + 200 < 0.5
30 V 0.01 300 + 200 < 0.5
100 V 0.01 300 + 200 < 0.5
300 V 0.01 300 + 200 < 0.5
600 V 0.01 300 + 200 < 0.5
1000 V 0.01 300 + 200 < 0.5
  1. Output range: 20 mV ~ 1100 V
  2. Manual or automatic range switch
  3. Adjustment fineness: 0.002%*RG
  4. 6 digits display
  5. Protections: short-circuit protection, overload protection, over-heat protection

6.4 AC Voltage(optional)

Range Resolution Output Range Frequency Max Burden(rms)
10 V 100 μV 1.0000 V ~ 11.0000 V 40 Hz ~ 400 Hz 800 mA
30 V 100 μV 3.0000 V ~ 33.0000 V 40 Hz ~ 400 Hz 700 mA
100 V 1 mV 10.000 V ~ 110.000 V 40 Hz ~ 400 Hz 200 mA
300 V 1 mV 30.000 V ~ 330.000 V 40 Hz ~ 400 Hz 70 mA
750 V 1 mV 75.000 V ~ 825.000 V 40 Hz ~ 400 Hz 30 mA
 
Range Stability
(±%/min)
Accuracy
 ±(ppm*RD+ppm*RG)
Distortion Factor (%)
10 V 0.01 300 + 200 <0.5
30 V 0.01 300 + 200 <0.5
100 V 0.01 300 + 200 <0.5
300 V 0.01 300 + 200 <0.5
750 V 0.01 300 + 200 <0.5
  1. Output range: 1 V ~ 825 V
  2. Frequency: 40 Hz ~ 400 Hz, adjustment fineness 0.001 Hz, accuracy ±0.01%.
  3. Manual or automatic range switch
  4. Adjustment fineness: 0.002%*RG
  5. 6 digits display
  6. Protections: short-circuit protection, overload protection, over-heat protection

6.5 DC Resistance(optional)

Range Resolution Output Range Accuracy
 ±(ppm*RD+ppm*RG)
Allowable Current
100 Ω 1 mΩ 10.000 Ω ~ 110.000 Ω 300 + 200 1 mA ~ 50 mA
1 kΩ 10 mΩ 0.10000 kΩ ~ 1.10000 kΩ 300 + 200 100 μA ~ 5 mA
10 kΩ 100 mΩ 1.0000 kΩ ~ 11.0000 kΩ 300 + 200 10 μA ~ 500 μA
100 kΩ 1 Ω 10.000 kΩ ~ 110.000 kΩ 300 + 200 10 μA ~ 50 μA
1 MΩ 10 Ω 0.10000 MΩ ~ 1.10000 MΩ 300 + 200 1 μA ~ 5 μA
10 MΩ 100 Ω 1.0000 MΩ ~ 11.0000 MΩ 600 + 400 100 nA ~ 500 nA
  1. Output range: 10 Ω ~ 11 MΩ
  2. Manual or automatic range switch
  3. Adjustment fineness: 0.002%*RG
  4. 6 digits display

6.6 AC\DC Power(optional)

Type Current Range Combination of Voltage and Current Accuracy
 ±(%*Power Output)[1] [2]
DC 1000 A (20 mV~1100 V) ×
(10 mA~1050 A)
0.07~0.29
2000 A [3] (20 mV~1100 V) ×
(10 mA~2100 A)
0.07~0.29
AC 1000 A (1 V~825 V) ×
(10 mA~1020 A)
0.07~0.42
2000 A[3] (1 V~825 V) ×
(10 mA~2050 A)
0.07~0.42
 
 

6.7 Phase and Power Factor(45 Hz~65 Hz)(optional)

Type Range Adjustment fineness Accuracy[1]
φ 0.000°~359.999° 0.005° 0.1°
λ -1 … 0 … +1 0.0001 0.30% @ (λ=0.5)
Note[1]: The accuracy formula of Power Factor:
 

7. General Specifications

Power supply AC (380±38)V,( 50 ± 2 ) Hz
Max Power Consumption 16 kVA @ 1000 A Model,32 kVA @ 2000 A Model
Operating Condition 0°C~40°C,(20%~85%) R·H,non-condensing
Storage Condition -20°C~70°C,(10%~95%) R·H,non-condensing
Standard Interfaces RS232×1
Dimensions Range Width(W) Depth(D) Height(H) Diameter of
 the copper ring
Ring 1(Ø1) Ring 2(Ø2)
1000 A 740 mm 1723 mm 1467 mm 10 mm 19 mm
2000 A 1480 mm 1723 mm 1467 mm 10 mm 27 mm
TD1050 Calibration Apparatus for Clamp Meters

8. Ordering information

TD1050 Calibration Apparatus for Clamp Meters
Function AC/DC Current Output
( ACI & DCI )
AC/DC Voltage Output
 ( ACV & DCV )
Resistance Output
(Res )
Power Output
(Power)
TD1050-X - - -
TD1050-X-M




 
Company Profile
 

TD1050 Calibration Apparatus for Clamp Meters

TD1050 Calibration Apparatus for Clamp Meters

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TD1050 Calibration Apparatus for Clamp Meters pictures & photos
TD1050 Calibration Apparatus for Clamp Meters
US $39,000-57,000 / Set
Min. Order: 1 Set
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013