• TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source
  • TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source
  • TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source
  • TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source
  • TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source
  • TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source

TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source

After-sales Service: Life Time
Warranty: 12 months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source pictures & photos
TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source
US $1,000-100,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TI5300
Customized
Non-Customized
DC Current Output
±(60 mA ~ 120 A)
DC Current Output Accuracy
Class 0.01
AC Current Output
60 mA ~ 120 A
AC Current Output Accuracy
Class 0.02
Sine wave frequency
40 Hz ~ 1 kHz
Voltage measurement range
±(10 mV ~ 12 V)
Current Measurement Range
±(1 mA ~ 1.1 A)
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China

Packaging & Delivery

Package Size
100.00cm * 100.00cm * 100.00cm
Package Gross Weight
50.000kg

Product Description

TI5300 AC/DC Current Sensor Testing Device

1. Summary
 
TI5300 is an instrument dedicated to testing sensors. It consists of an AC and DC current standard source, a sensor output power measurement module and an auxiliary power supply. It can directly measure the ratio difference, angular difference, power consumption and other parameters of the current sensor.

2. Features
  1. The sensor was tested using the standard source method.
  2. DC current output: ±(60 mA ~ 120 A), class 0.01
  3. AC current output: 60 mA ~ 120 A, class 0.02
  4. Sine wave frequency: 40 Hz ~ 1 kHz
  5. Built-in sensor secondary output power measurement module
  6. Built-in sensor auxiliary power supply and power consumption measurement module
  7. Supports testing of sensor ratio difference and angle difference.
  8. Equipped with a transfer box, it can be adapted to a variety of sensor output interfaces.
  9. LCD touch screen
  10. Testing software (optional).
3. Application
TUNKIA TI5300 AC DC Current Sensor Transformer Transducer Test Bench Calibration Device with AC DC Power Standard Source
 
 Test AC and DC Sensors
  1. Use standard source method, that is, the TI5300 outputs the standard current I1 to the sensor being tested, and simultaneously measures its secondary output signal to detect the ratio difference, angular difference, linearity, etc. of the DUT.
  2. Sensor auxiliary power supply: adjustable within the range of DC ±(5.0 V~50.0 V), supporting power consumption measurement.
  3. Configure a transfer box to adapt to various sensor output interfaces such as DB9 serial port.
  4. Suitable for testing DC current sensors of class 0.05 and below, and AC current sensors of class 0.1 and below.
 
4. Instrument Appearance
TUNKIA TI5300 AC DC Current Sensor Transformer Transducer Test Bench Calibration Device with AC DC Power Standard Source
 
 Front Panel
N0. Function
1 LCD touch screen
2 Operation button panel
3 Sensor output power measurement and power supply interface
4 Current output terminal: outputs a maximum of 120 A AC and DC current.

TUNKIA TI5300 AC DC Current Sensor Transformer Transducer Test Bench Calibration Device with AC DC Power Standard Source
 
 
 Rear Panel
N0. Function
1 Handle
2 Cooling vent
3 Ground terminal
4 RS232
5 Power switch and interfaces
6 Foldable feet
 

5.Characteristics

TUNKIA TI5300 AC DC Current Sensor Transformer Transducer Test Bench Calibration Device with AC DC Power Standard Source
 Directly Displays Sensor Ratio Difference and Angle Difference
  1. The embedded software interface can display the primary current output value and secondary signal measurement value.
  2. Directly display the ratio difference and angular difference measurement results of the tested sensor.

TUNKIA TI5300 AC DC Current Sensor Transformer Transducer Test Bench Calibration Device with AC DC Power Standard Source
 Ripple and Distortion Measurements
  1. Supports the measurement of ripple and distortion of the sensor's secondary output signal.

TUNKIA TI5300 AC DC Current Sensor Transformer Transducer Test Bench Calibration Device with AC DC Power Standard Source
 
 Sensor Auxiliary Power Supply And Power Consumption Measurement
  1. TI5300 comes standard with an adjustable power supply within the range of DC ±(5.0 V ~ 50.0 V), no external power supply is required.
  2. It supports the input power impact test of the sensor and can also measure the power consumption of the sensor.
 

6. Specification

6.1 AC and DC Current Standard Sources

Current Range Resolution Frequency
(Hz)
Short-term Stability
(ppm/min)
Measurement Uncertainty(k=2)
(ppm*RD+ppm*RG)[1]
Temperature
Coefficient
(ppm*RG/°C)
Compliance voltage
(Vrms)
300 mA 100 nA DC 30 60 + 40 5 2
45~200 150 250 + 100 10 1.5
200~1k 150 300 + 200 10 1.0
1 A 1 μA DC 30 60 + 40 5 2
45~200 100 200 + 100 10 1.2
200~1k 100 300 + 200 10 1.0
3 A 1 μA DC 30 60 + 40 5 2
45~200 100 200 + 100 10 1.2
200~1k 100 300 + 200 10 1.0
10 A 10 μA DC 30 60 + 40 5 2
45~200 100 150 + 50 10 1.2
200~1k 100 200 + 100 10 1.0
30 A 10 μA DC 30 60 + 40 5 2
45~200 100 150 + 50 10 1.0
200~1k 100 200 + 100 10 0.6
100 A 100 μA DC 30 60 + 40 5 1.5
45~200 100 150 + 50 10 0.8
200~1k 100 200 + 100 10 0.5
Note [1]: RD is the reading value, RG is the range value, the same below
  1. Output range: ±(60 mA~120 A), adjustment fineness: 0.001%*RG, 7-digit decimal display.
  2. Output frequency: DC, 40 Hz ~ 1 kHz, ripple coefficient/distortion: <0.5%
  3. Protection functions: open circuit protection, overload protection, overheating protection

6.2 Sensor Secondary Power Measurement

Current Range 10 mA, 100 mA, 1 A, manual/automatic range switching
Current Measurement Range ± (1 mA ~ 1.1 A)
Voltage Range 100 mV, 1 V, 10 V, manual/automatic range switching
Voltage Measurement Range ± (10mV ~ 12V)
Measurement Frequency DC, AC 45 Hz ~ 1 kHz
Measurement Uncertainty (k=2)(ppm*RD+ppm*RG) DC: 30 + 20
AC: 60 + 40
Display Digits 7-digit decimal
Note [1]: RD is the reading value, RG is the range value, the same below
 

6.3 Sensor Power Supply and Power Consumption Measurement

Supply Voltage DC ± (5.0 V~50.0 V) adjustable
Maximum Load Capacity 1A
Measurement Uncertainty (k=2) Voltage/Current: 0.2%, Power: 0.5%
Protective Function Short circuit protection, overload protection, overheating protection
 

7. General Specification

Power Supply AC (220±22) V, (50±2) Hz
Maximum Power Consumption 1.5 kVA
Preheat Time 30mins
Working Environment Temperature: 0°C ~ 40°C
Humidity: 20%R·H ~ 85%R·H, non-condensing
Others: No electromagnetic field interference.
Storage environment Temperature: -20°C ~ 70°C
Humidity: <95%R·H, non-condensing
Communication Interface RS232×1
Device Size 440 mm (W) × 450 mm (D) × 230 mm (H)
Weight Approx 30 kg


 
Company Profile
 

TUNKIA TI5300 AC DC Current Sensor Transformer Transducer Test Bench Calibration Device with AC DC Power Standard Source

TUNKIA TI5300 AC DC Current Sensor Transformer Transducer Test Bench Calibration Device with AC DC Power Standard SourceTUNKIA TI5300 AC DC Current Sensor Transformer Transducer Test Bench Calibration Device with AC DC Power Standard Source

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source pictures & photos
TUNKIA TI5300 AC DC Current Sensor Transformer  Transducer Test Bench Calibration Device with AC DC Power Standard Source
US $1,000-100,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013