TD1250  Earth Continuity Testers Calibration Device

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 12 Months Excellent for Service
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013
  • TD1250  Earth Continuity Testers Calibration Device
  • TD1250  Earth Continuity Testers Calibration Device
  • TD1250  Earth Continuity Testers Calibration Device
  • TD1250  Earth Continuity Testers Calibration Device
  • TD1250  Earth Continuity Testers Calibration Device
  • TD1250  Earth Continuity Testers Calibration Device
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD1250
Power
Electricity
Voltage Output
264V
Current Output
120A
LCD Display
With LCD Display
Customized
Non-Customized
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Packaging & Delivery

Package Size
55.00cm * 40.00cm * 30.00cm
Package Gross Weight
18.000kg

Product Description

TD1250 Testing Apparatus for Earth Continuity TestersTD1250 Earth Continuity Testers Calibration Device

1. Summary

TD1250 is a precision AC/DC artificial resistance, intergraded a AC/DC ammeter. Applied for calibrating earth continuity tester and other AC/DC low resistance instruments. It can calibrate max permissible error, alarm setting error, test current setting error etc.
 

2. Features

  1. DC resistance simulation:200 μΩ (100 μΩ optional)~20 Ω.
  2. AC resistance simulation:500 μΩ (300 μΩ optional)~15 Ω.
  3. AC/DC current measurement:0.5 A~36 A(60A option).
  4. Accuracy class:0.02/ 0.05/ 0.1.
  5. Harmonic and ripple function.
  6. Current waveform display function.
  7. With data statistics and analysis, stability test function.
  8. LCD touch screen.
  9. Setting output values by keys.

3. Applications

TD1250 Earth Continuity Testers Calibration Device

 

4. Characteristics

 Resistance Output
TD1250 Earth Continuity Testers Calibration Device
  1. Using four-terminals connections, can effective eliminate the measurement error introduced by the lead resistance.


 
 Multiple Output Mode
TD1250 Earth Continuity Testers Calibration Device
  1. "Direct output"mode,User can set output value by physical key or touch screen.
TD1250 Earth Continuity Testers Calibration Device
  1. "Rotary Knob"mode,User can setting in clockwise direction or anticlockwise direction.



 
 Multiple Output Mode
TD1250 Earth Continuity Testers Calibration Device
  1. Touch "Calibration point"of screen for "% setting".


 

 AC+DC Measurement
TD1250 Earth Continuity Testers Calibration Device
  1. Support DC/AC)measurement mode. AC frequency range:45 Hz ~ 65 Hz.
  2. Distortion and ripple test,max bandwidth of DC ripple reaches 1 kHz. Supports 2nd~32nd harmonics.



 
 DC Characteristic Analysis
TD1250 Earth Continuity Testers Calibration Device
Serial Number Explanation
  Current overshoot : The maximum value of the test current is displayed in DC mode, which is used to calculate the operating current overshoot;
  Waveform display:With oscilloscope function ,can real time display of measured current waveform.
  Ripple measurement:the instrument directly displays the ripple measurement results on the screen for users to read.



 
 AC Characteristic Analysis
TD1250 Earth Continuity Testers Calibration Device
Serial Number Explanation
  Harmonic distortion:Display THD/T(harmonic vs. full wave),THD/F(harmonic vs. fundamental). Easy for users to real intuitively.
  Harmonic data:Display the amplitude (RMS), content(%), phase of the 2nd~32nd harmonic, facilitate user analysis.
  DC component:Display the DC component in the AC current signal. Easy for users to real intuitively.
  Waveform display:with waveform display function, real time display of measured current waveform.




 
 Statistical Analysis
TD1250 Earth Continuity Testers Calibration Device
Serial Number Function Description
  Scoring cycle:0.5 s ~ 20 s integration period can be set(1s by default); it is convenient for users to set sampling data according to actual needs.
  Statistical analysis:Real time record and statistics of current test data, including Max, Min, Avg, Span, Stab, S.dev, Time, test times N,etc; Easy for users to real intuitively.


 

5. Specifications

5.1 DC Current Measurement 

Range Resolution Accuracy
±(ppm of reading + ppm of range) [1]
Class 0.1 Class 0.05 Class 0.02
1 A 10 μA 0.05 + 1.5 0.02 + 1.0 0.01 + 0.5
2 A 10 μA 0.05 + 1.5 0.02 + 1.0 0.01 + 0.5
5 A 10 μA 0.05 + 1.5 0.02 + 1.0 0.01 + 0.5
10 A 100 μA 0.05 + 1.5 0.02 + 1.0 0.01 + 0.5
20 A 100 μA 0.05 + 2.5 0.02 + 2.0 0.01 + 1.0
30 A 100 μA 0.05 + 5.0 0.02 + 3.0 0.01 + 2.0
50 A [2] 100 μA 0.05 + 5.0 0.02 + 3.0 0.01 + 2.0
Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%). Note [2]: 50 A Range is optional Accessories
  1. Measuring range(TD1250-30A specification, max range:30 A):0.5 A~36 A.
  2. Measuring range(TD1250-50A specification, max range: 50 A):0.5 A~60 A.
  3. Ripple frequency bandwidth: 1 Hz ~ 1 kHz, accuracy: ±0.02%*RG,effective value.
 

5.2 AC Current Measurement

Range Resolution Accuracy
±(ppm of reading + ppm of range) [1]
Class 0.1 Class 0.05 Class 0.02
1 A 10 μA 0.10 + 3.0 0.05 + 2.0 0.02 + 1.0
2 A 10 μA 0.10 + 3.0 0.05 + 2.0 0.02 + 1.0
5 A 10 μA 0.10 + 3.0 0.05 + 2.0 0.02 + 1.0
10 A 100 μA 0.10 + 3.0 0.05 + 2.0 0.02 + 1.0
20 A 100 μA 0.10 + 5.0 0.05 + 3.0 0.02 + 2.0
30 A 100 μA 0.10 + 10 0.05 + 5.0 0.02 + 5.0
50 A[2] 100 μA 0.10 + 10 0.05 + 5.0 0.02 + 5.0
  1. Measuring range(TD1250-30A specification, max range:30 A):0.5 A~36 A.
  2. Measuring range(TD1250-50A specification, max range: 50 A):0.5 A~60 A.
  3. AC frequency: 45 Hz ~ 65 Hz, accuracy: ±0.01 Hz, harmonic measurement: 2nd~32nd.
 

5.3 DC Simulated Resistance

Current Range Setting Range of Resistance Value R Adjustment Fineness Accuracy
±(A%*reading+R0)
Class 0.1 Class 0.05 Class 0.02
50 A [2] 100 μΩ ≤ R ≤ 4 mΩ 20 nΩ 0.1 + 3 μΩ 0.08 + 1.5 μΩ 0.04 + 0.8 μΩ
4 mΩ < R ≤ 40 mΩ 200 nΩ 0.1 + 3 μΩ 0.06 + 1.5 μΩ 0.03 + 0.8 μΩ
40 mΩ < R ≤ 400 mΩ 2 μΩ 0.1 0.05 0.02
30A 200 μΩ ≤ R ≤ 6 mΩ 30 nΩ 0.1 + 5 μΩ 0.08 + 3 μΩ 0.04 + 1.5 μΩ
6 mΩ < R ≤ 60 mΩ 300 nΩ 0.1 + 5 μΩ 0.06 + 3 μΩ 0.03 + 1.5 μΩ
60 mΩ < R ≤ 600 mΩ 3 μΩ 0.1 0.05 0.02
20A 400 μΩ ≤ R ≤ 10 mΩ 100 nΩ 0.1 + 6 μΩ 0.08 + 5 μΩ 0.04 + 2.5 μΩ
10 mΩ < R ≤ 100 mΩ 1 μΩ 0.1 + 6 μΩ 0.06 + 5 μΩ 0.03 + 2.5 μΩ
100 mΩ ≤ R ≤ 1 Ω 10 μΩ 0.1 0.05 0.02
10A 800 μΩ ≤ R ≤ 20 mΩ 100 nΩ 0.1 + 15 μΩ 0.08 + 6 μΩ 0.04 + 3 μΩ
20 mΩ < R ≤ 200 mΩ 1 μΩ 0.1 + 15 μΩ 0.06 + 6 μΩ 0.03 + 3 μΩ
200 mΩ < R ≤ 2 Ω 10 μΩ 0.1 0.05 0.02
5A 1.6 mΩ ≤ R ≤ 40 mΩ 200 nΩ 0.15 + 30 μΩ 0.09 + 15 μΩ 0.045 + 6 μΩ
40 mΩ < R ≤ 400 mΩ 2 μΩ 0.12 + 30 μΩ 0.07 + 15 μΩ 0.035 + 6 μΩ
400 mΩ < R ≤ 4 Ω 20 μΩ 0.1 0.05 0.025
2A 4 mΩ ≤ R ≤ 100 mΩ 1 μΩ 0.20 + 50 μΩ 0.10 + 30 μΩ 0.055 + 15 μΩ
100 mΩ < R ≤ 1 Ω 10 μΩ 0.20 + 50 μΩ 0.10 + 30 μΩ 0.045 + 15 μΩ
1 Ω < R ≤ 10 Ω 100 μΩ 0.1 0.05 0.035
1A 8 mΩ ≤ R ≤ 200 mΩ 1 μΩ 0.30 + 90 μΩ 0.15 + 50 μΩ 0.08 + 30 μΩ
200 mΩ < R ≤ 2 Ω 10 μΩ 0.30 + 90 μΩ 0.15 + 50 μΩ 0.07 + 30 μΩ
2 Ω < R ≤ 20 Ω 100 μΩ 0.2 0.1 0.06
Note [2]: 50 A Range is optional Accessories
  1. Simulated resistance range(TD1250-30A specification, maximum range: 30 A):200 μΩ~20 Ω
Simulated resistance range(TD1250-50A specification, maximum range: 50 A):100 μΩ~20 Ω
  1. Display Digits:6-digit decimal display, set the resistance value through the number keys.

5.4 AC Simulated Resistance

Current Range Setting Range of Resistance Value R Adjustment Fineness Accuracy
±(A%*reading+R0)
Class 0.1 Class 0.05 Class 0.02
50 A [2] 300 μΩ ≤ R ≤ 3 mΩ 20 nΩ 0.3 + 5 μΩ 0.15 + 3 μΩ 0.08 + 1.5 μΩ
3 mΩ < R ≤ 30 mΩ 200 nΩ 0.24 + 5 μΩ 0.12 + 3 μΩ 0.06 + 1.5 μΩ
30 mΩ < R ≤ 300 mΩ 2 μΩ 0.2 0.1 0.04
30A 500 μΩ ≤ R ≤ 5 mΩ 30 nΩ 0.3 + 8 μΩ 0.15 + 5 μΩ 0.08 + 2.5 μΩ
5 mΩ < R ≤ 50 mΩ 300 nΩ 0.24 + 8 μΩ 0.12 + 5 μΩ 0.06 + 2.5 μΩ
50 mΩ < R ≤ 500 mΩ 3 μΩ 0.2 0.1 0.04
20A 750 μΩ ≤ R ≤ 7.5 mΩ 50 nΩ 0.3 + 10 μΩ 0.15 + 6 μΩ 0.08 + 4 μΩ
7.5 mΩ < R ≤ 75 mΩ 500 nΩ 0.24 + 10 μΩ 0.12 + 6 μΩ 0.06 + 4 μΩ
75 mΩ ≤ R ≤ 750 mΩ 5 μΩ 0.2 0.10 0.04
10A 1.5 mΩ < R ≤ 15 mΩ 100 nΩ 0.3 + 20 μΩ 0.15 + 12 μΩ 0.08 + 8 μΩ
15 mΩ < R ≤ 150 mΩ 1 μΩ 0.24 + 20 μΩ 0.12 + 12 μΩ 0.06 + 8 μΩ
150 mΩ < R ≤ 1.5 Ω 10 μΩ 0.2 0.1 0.04
5A 3 mΩ ≤ R ≤ 30 mΩ 200 nΩ 0.3 + 20 μΩ 0.2 + 15 μΩ 0.1 + 12 μΩ
30 mΩ < R ≤ 300 mΩ 2 μΩ 0.3 + 20 μΩ 0.15 + 15 μΩ 0.07 + 12 μΩ
300 mΩ < R ≤ 3 Ω 20 μΩ 0.2 0.1 0.05
2A 7.5 mΩ ≤ R ≤ 75 mΩ 5 μΩ 0.4 + 80 μΩ 0.2 + 50 μΩ 0.11 + 30 μΩ
75 mΩ < R ≤ 750 mΩ 50 μΩ 0.4 + 80 μΩ 0.2 + 50 μΩ 0.09 + 30 μΩ
750 mΩ < R ≤ 7.5 Ω 500 μΩ 0.2 0.14 0.07
1A 15 mΩ ≤ R ≤ 150 mΩ 1 μΩ 0.6 + 150 μΩ 0.3 + 90 μΩ 0.16 + 60 μΩ
150 mΩ < R ≤ 1.5 Ω 10 μΩ 0.6 + 150 μΩ 0.3 + 90 μΩ 0.14 + 60 μΩ
1.5 Ω < R ≤ 15 Ω 100 μΩ 0.4 0.2 0.12
Note [2]: 50 A Range is optional Accessories
  1. Simulated resistance range(TD1250-30A specification, maximum range: 30 A):500 μΩ~15 Ω.
Simulated resistance range(TD1250-50A specification, maximum range: 50 A):300 μΩ~15 Ω.
  1. Display Digits:6-digit decimal display, set the resistance value through the number keys.
  2. AC frequency: 45 Hz ~ 65 Hz, accuracy: ±0.01 Hz.

6. General Specifications

Power Supply AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
Temperature Performance Working temperature:0°C~45°C;
Storage temperature:-20°C~70°C
Humidity Performance Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C
Storage humidity:(20%~80%) R·H,non-condensing
Interface RS232
 

7. Ordering Information

TD1250 Earth Continuity Testers Calibration Device
 
Company Profile
 

TD1250 Earth Continuity Testers Calibration Device


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier