Advanced Current Transducer Measurement Analyzer for Precision Testing
Contact Supplier
Product Highlights
- High Precision Measurement: Class 0.005 accuracy for ratio error and phase displacement testing.
- Multi-Frequency Support: Operates in 45 Hz to 65 Hz range with support for multi-frequency point measurement.
- Automatic Demagnetization: Built-in function to evaluate magnetic resistance and prepare transformer cores.
- Harmonic Measurement: Capable of measuring harmonics from the 2nd to the 63rd order.
- Lifetime Warranty Coverage: Includes 12 months excellent after-sales service with lifetime warranty commitment.
- Advanced Software Integration: Supports drawing frequency and current characteristic curves via optional test software.
Product Attributes
- Customization
- Available
- After-sales Service
- Life Time
- Warranty
- 12 Months Excellent After-Sales Service
- Model NO.
- TH0690
- Application
- Electromagnetic Instrument, Electrical Calibration
- Power
- Electricity
- LCD Display
- With LCD Display
- Customized
- Non-Customized
- Transport Package
- Package for Exporting
- Trademark
- TUNKIA
- Origin
- China
- Production Capacity
- 1000
- Package Size
- 50.00cm * 50.00cm * 40.00cm
- Package Gross Weight
- 20.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of Advanced Current Transducer Measurement Analyzer for Precision Testing
Find Similar Products
Product Description
1. Summary
TH0690 is an intelligent instrument dedicated to the comprehensive performance evaluation of current transducers. It can accurately test the electrical characteristics such as ratio error (k) and phase displacement (δ) of I/I and I/V current transformers, and can also measure the AC magnetic characteristics of the transformer core. It solves the problem of complex calculation of the relationship between magnetic properties and electrical properties in the process of transducers design, and provides the most complete means for the analysis and measurement of current transformers.2. Feature
- AC Power Output/Measurement Accuracy: Class 0.005
- Working Frequency Range: 45 Hz~65 Hz.
- Support multi-frequency point measurement of ratio error (k) and phase displacement (δ)
- Draw frequency or current characteristic curve with the software.
- Support various magnetic characteristic parameter measurement and curve drawing.
- With automatic demagnetization function, it can evaluate the magnetic resistance of the transformer.
- Special Test Software (optional)
3. Application
- Current transformer ratio error (k) and phase displacement (δ) calibration.
- Magnetic performance testing of finished transformers and semi-finished iron cores.
- Current transformer quality inspection, design verification, iron core pairing.
- Ratio error (k) and phase displacement (δ) measurement of the current measurement circuit.
- Anti-magnetic evaluation of current transformers.
| ☆ Current transformer ratio error and phase displacement calibration. |
![]() |
|
| ☆ Measuring the magnetic properties of core semi-finished products. |
![]() |
|
4. specifications
4.1 ACI Output/ I1
| Current Range | Short-term Stability (%/min) |
Measurement Uncertainty (k=2, ppm*RD+ppm*RG)1 |
Maximum Load Voltage(V) | Distortion (%) |
||
| 24 h (23±1)°C |
90 days (23±5)°C |
1 year (23±5)°C |
||||
| 2 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 5 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 10 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 20 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 50 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 100 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 200 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 500 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 1 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 2 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 5 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 10 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 20 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 50 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| 100 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
| Note: 1 RD is the reading value, RG is the range value, the same below. | ||||||
- ACI Output:200 μA~120 A,7-digit display.
- Frequency range: 45 Hz~65 Hz; Adjustment Fineness: 0.0001 Hz; Measurement Uncertainty: 0.001 Hz
- Protection Function: short circuit protection, overload protection.
4.2 ACV Measurement /U2 and ACI Measurement/I2
| AC | Range | Resolution | Measurement Uncertainty (k=2, ppm*RD +ppm*RG) |
||
| 24 h (23±1)°C |
90 days (23±5)°C |
1 year (23±5)°C |
|||
| ACV/U2 | 20 mV | 10 nV | 40 + 40 | 50 + 40 | 60 + 40 |
| 50 mV | 10 nV | 20 + 20 | 25 + 20 | 30 + 20 | |
| 100 mV | 100 nV | 20 + 20 | 25 + 20 | 30 + 20 | |
| 200 mV | 100 nV | 20 + 20 | 25 + 20 | 30 + 20 | |
| 500 mV | 100 nV | 20 + 20 | 25 + 20 | 30 + 20 | |
| 1 V | 1 μV | 20 + 20 | 25 + 20 | 30 + 20 | |
| 2 V | 1 μV | 20 + 20 | 25 + 20 | 30 + 20 | |
| 5 V | 1 μV | 20 + 20 | 25 + 20 | 30 + 20 | |
| ACI/I2 | 200 μA | 0.1 nA | 20 + 20 | 25 + 20 | 30 + 20 |
| 500 μA | 0.1 nA | 20 + 20 | 25 + 20 | 30 + 20 | |
| 1 mA | 1 nA | 20 + 20 | 25 + 20 | 30 + 20 | |
| 2 mA | 1 nA | 20 + 20 | 25 + 20 | 30 + 20 | |
| 5 mA | 1 nA | 20 + 20 | 25 + 20 | 30 + 20 | |
| 10 mA | 10 nA | 20 + 20 | 25 + 20 | 30 + 20 | |
| 20 mA | 10 nA | 20 + 20 | 25 + 20 | 30 + 20 | |
| 50 mA | 10 nA | 20 + 20 | 25 + 20 | 30 + 20 | |
| 100 mA | 100 nA | 20 + 20 | 25 + 20 | 30 + 20 | |
- U2 Measurement Range: 2 mV~5.5 V,7-digit display.
- I2 Measurement Range: 20 μA~110 mA,7-digit display.
- Harmonic Measurement: 2nd to 63rd.
4.3 Ratio Error (k) and Phase Displacement (δ) Measurement
| Ratio Error | Measurement Range | Current transformer input current like I1 Current transformer output current like I2 |
| Measurement Uncertainty (k=2) |
0.01% @ 45 Hz ~ 65 Hz | |
| Phase Displacement | Measurement Range | 0.000°~359.999° |
| Measurement Uncertainty (k=2) |
0.001° @ 45 Hz~65 Hz |
4.4 Measurement of Magnetic Parameters of Current Transformer Iron Core
| Measured Parameters | Measurement Uncertainty (k=2) |
Measurement Repeatability |
| μi | 1.5% | 4.0% |
| μm | 1.0% | 2.0% |
| Hc | 0.5% | 1.0% |
| Br | 0.3% | 1.0% |
| Bs | 0.3% | 1.0% |
| μa | 1.0% | 3.0% |
| Bm | 0.5% | 1.0% |
| Hm | 1.0% | 2.0% |
| δ | 1.5% | 5.0% |
| Hc | 1.0% | 3.0% |
| Br | 1.0% | 3.0% |
| μ' | 1.0% | 3.0% |
| μ′′ | 1.0% | 3.0% |
| μL | 1.0% | 3.0% |
| Note: The iron core should be demagnetized before the test, and the parameters of the iron core should be input as required. The measurement temperature T: (23±5)°C. | ||
About the Supplier
This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI2191183". Items marked "" are certified.
Company Profile
TUNKIA Co., Ltd. is a unique company with top R& D strength in electromagnetics in China. Since its founding in 1998, Changed its name to TUNKIA in 2006. TUNKIA focus on electromagnetic measurement technology, gathered more than 360 personnel all over the world.
At present, Tunkia has launched 32 categories and over 500 advanced electromagnetic measurement equipment, serving over 10, 000 users, and exported to over 20 countries in the world.
Electrical measurement with current from PA to 10kA, voltage from nV to 100kV, resistance from nΩ To TΩ , frequency from DC to 10MHz and accuracy from 10-4 to 10-6. It all have been converted into 22 series electrical testing equipment: Measurement standards, AC & DC instruments, new energy detection, etc.
For magnetic measurement, Tunkia has researched 11 series testing equipment for material and products. We provide comprehensive testing solutions about magnetic intensity, flux, permeability, hysteresis loop, etc.
Tunkia have been highly recognized by the Chinese government and international organizations. Since 2014, we have took part in IEC meetings on behalf of China, participated in the formulation and revision of more than 40 national standards.
Tunkia is striving to become a world-class supplier of electromagnetic measurement equipment.
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory
- Address
- No. 16 Panpan Road, Changsha, Hunan, China
-
Plant Area
- 8000 square meters
-
Number of Employees
- 363
-
Registered Capital
- 25,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR, EXW
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: one month -
Nearest Port
- Changsha Port
Our Production Capability & Technical Expertise
-
Main Products
- Magnetic Measurement, Electrical Measurement, Gaussmeter, Multifunction Calibrator
-
Production Machines
- SMT Machine, Printing Machine, Assembly & Debugging Line, Automatic Online Function Test (EPS&SST)
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 120 people
-
Own Brand
- Yes
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2006-06-16
- Export Year
- 2021-10-11
-
Main Markets
- Europe, Southeast Asia/ Mideast, East Asia(Japan/ South Korea), Domestic
-
Number of Foreign Trading Staff
- 2
-
Overseas Agent/Branch
- No
FAQ
- What is the measurement accuracy of the analyzer?
- The device offers Class 0.005 accuracy for ratio error and phase displacement measurements.
- What is the warranty period for this product?
- It comes with a 12-month warranty and lifetime after-sales service commitment.
- Does the analyzer support frequency variation testing?
- Yes, it operates within 45 Hz to 65 Hz and supports multi-frequency point measurements.
- Is the product customizable?
- No, this model is Non-Customized.
- What is the lead time for orders?
- The average lead time is one month for both peak and off-peak seasons.
- What payment methods are accepted?
- Accepted methods include LC, T/T, D/P, PayPal, and Western Union.
Send your message to this supplier
People who viewed this also viewed
-
US$1,000.00-10,000.00 / Piece
-
US$1,000.00-10,000.00 / Piece
-
US$1,000.00-10,000.00 / Piece
-
US$1,000.00-10,000.00 / Piece
-
US$700.00-1,000.00 / Set
-
US$1,000.00-10,000.00 / Set
-
US$1,000.00-1,500.00 / Piece
-
US$1,000.00-1,500.00 / Piece
-
US$30,000.00-35,000.00 / Set
-
US$1,000.00-10,000.00 / Piece
Product Groups
- Multi-function Calibrators Series
- EV Charger Tester
- Electrical Reference Standards
- Resistance Standards Series
- DC Power Energy Standards
- Wideband Power Source/Meter
- AC/DC Current Source/Meter
- Single/Three Phase Energy Meter Calibration
- Single/Three Phase Standard Meter
- High Voltage Standard Instrument
- Industrial Instrument Testing
- Safety Instrument Detection
Find Similar Products By Category
- Supplier Homepage
- Products
- Electrical Reference Standards
- Advanced Current Transducer Measurement Analyzer for Precision Testing
Related Categories
Hot Searches
- Current Meter Factories
- Battery Tester Factories
- China Tester Factories
- Analyzer Equipment Factories
- Current Tester
- Ct Analyzer
- High Current Tester
- Electric Current Tester
- Current Analyzer
- of ct analyzer Bulkbuy