TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 12 Months Excellent After Service
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
8000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2016, Intellectual Property Management System Certificate, ISO 27001:2013
  • TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
  • TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
  • TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
  • TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
  • TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
  • TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
TD3100
Application
Electrical Calibration
Power
Electricity
LCD Display
With LCD Display
Customized
Non-Customized
Accuracy
Class 0.02/Class 0.05
Voltage Measurement
6 V~528 V(customizable)
Current Measurement
1 mA~120 A
Frequency
45 Hz~65 Hz/400Hz
Transport Package
Package for Exporting
Trademark
TUNKIA
Origin
China
Production Capacity
1000

Product Description

TD3100 Single Phase Multifunction Standard Meter
TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument

1. Summary

The TD3100 is a high-precision single-phase standard instrument that can simultaneously measure multiple electrical charges in the loop such as: voltage, current, frequency, phase, harmonics, active power/energy, reactive power/energy, apparent power, power factor, etc.
 

2. Features

· Optional power/energy accuracy: class 0.02, class 0.05 
· Voltage measurement: 6 V~528 V (wider range can be customized).
· Current measurement: 1 mA~120 A.
· Fundamental frequency: 45 Hz~65 Hz (optional 400Hz).
· Phase measurement uncertainty: 0.006° (class 0.02).
· Voltage and current support fully automatic range shifting.
·  Voltage and current support 2~63rd harmonic measurement.
· Support comprehensive statistical analysis of the measured electricity.
· Standard energy pulse input/output.
· USB, RS232, LAN interfaces.
· LCD touch screen.

 

3. Application

☆ Single-phase Energy Measurement Standard
TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
It can be used as a standard meter for single-phase energy meter verification devices that meet R46 requirements



 
☆ Calibrate Single-phase Power Source/Meter
TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
It is suitable for calibrating single/three-phase power sources with Class 0.05 and below, power meters/standard energy meters (stable power sources are required).

4. Characteristics

☆ Comprehensive Analysis of AC Power
TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
S/N Function
1 Oscilloscope function: displays the waveform of the measured power in real time.
2 Accurately measure the phase between the voltage and current of each phase.
3 Calculate two types of harmonic distortion: THD/T (harmonic relative to full wave) and THD/F (harmonic relative to fundamental wave).
4 Analysis the amplitude (RMS), content (%) and phase of the 2nd~63rd harmonic of each phase voltage or current in real time.
5 Visualize the spectrum of each harmonic (100% fundamental) in the form of a histogram.


 
☆ Data statistical Analysis Function
TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
S/N Function
1 Data statistical analysis: calculate the maximum (Max), minimum value (min), peak-to-peak (P-P), average value (AVG), standard deviation (S.dev), etc. of the measured electricity.
2 Battery Stability Test: curve the amount of electricity over time in real time.
3 Normal distribution histogram: displays the distribution of the amount of electricity.
4 Power stability test: automatically measure the output power stability of the tested energy device according to the algorithm of JJG 597-2005



 
☆ Rich Communication Interface
TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
Rich communication interfaces: RS232, USB, LAN and other.

5. Specifications

5.1 Single-phase voltage measurement

Range Resolution
Measurement uncertainty ( k = 2 )
( ppm*RD + ppm*RG ) [1]
Temperature coefficient @ (15~30)°C
(ppm*RD+ppm*RG) /°C
Class 0.05 Class 0.02 Class 0.05 Class 0.02
60 V 10 μV 200 + 50 60 + 40 < 10 0.5 + 0.5
120 V 0.1mV 200 + 50 60 + 40 < 10 0.5 + 0.5
240 V 0.1mV 200 + 50 60 + 40 < 10 0.5 + 0.5
480 V 0.1mV 200 + 50 60 + 40 < 10 0.5 + 0.5
Note [1]: RD is the reading value, RG is the range value, the same below.
Measuring range: 6 V~528 V (wider range can be customized), 7-digit display, manual/automatic range shifting
 

5.2 Single-phase current measurement

(1) Class 0.02
 
Range Resolution Measurement uncertainty at different frequencies (Hz) (k = 2).
( ppm*RD + ppm*RG )
Temperature coefficient @ (15~30)°C
(ppm*RD+ppm*RG) /°C
45 ≤ F ≤ 65 65 < F ≤ 200 200 < F ≤ 400
10 mA 10 nA 120 + 80 240 + 160 480 + 320 5 + 5
20 mA 10 nA 120 + 80 240 + 160 480 + 320 1.25 + 1.25
50 mA 10 nA 60 + 40 120 + 80 240 +160 0.5 + 0.5
100 mA 0.1 μA 60 + 40 120 + 80 240 +160 0.5 + 0.5
200 mA 0.1 μA 60 + 40 120 + 80 240 +160 0.5 + 0.5
500 mA 0.1 μA 60 + 40 120 + 80 240 +160 0.5 + 0.5
1 A 1 μA 60 + 40 120 + 80 240 +160 0.5 + 0.5
2 A 1 μA 60 + 40 120 + 80 240 +160 0.5 + 0.5
5 A 1 μA 60 + 40 120 + 80 240 +160 0.5 + 0.5
10 A 10 μA 60 + 40 120 + 80 240 +160 0.5 + 0.5
20 A 10 μA 60 + 40 120 + 80 240 +160 0.5 + 0.5
50 A 10 μA 60 + 40 120 + 80 240 +160 0.5 + 0.5
100 A 100 μA 60 + 40 120 + 80 240 +160 0.5 + 0.5
Measuring range: 1 mA~120 A, 7-digit display, manual/automatic range shifting

(2) Class 0.05 

 
Range Resolution
Measurement uncertainty at different frequencies (Hz) (k = 2).
( ppm*RD + ppm*RG )
Temperature coefficient @ (15~30)°C
ppm*RD/°C
45 ≤ F ≤ 65 65 < F ≤ 200 200 < F ≤ 400
10 mA 10 nA 300 + 200 600 + 400 1200 + 800 < 30
20 mA 10 nA 300 + 200 600 + 400 1200 + 800 < 10
50 mA 10 nA 200 + 50 400 + 100 800 + 200 < 10
100 mA 0.1 μA 200 + 50 400 + 100 800 + 200 < 10
200 mA 0.1 μA 200 + 50 400 + 100 800 + 200 < 10
500 mA 0.1 μA 200 + 50 400 + 100 800 + 200 < 10
1 A 1 μA 200 + 50 400 + 100 800 + 200 < 10
2 A 1 μA 200 + 50 400 + 100 800 + 200 < 10
5 A 1 μA 200 + 50 400 + 100 800 + 200 < 10
10 A 10 μA 200 + 50 400 + 100 800 + 200 < 10
20 A 10 μA 200 + 50 400 + 100 800 + 200 < 10
50 A 10 μA 200 + 50 400 + 100 800 + 200 < 10
100 A 100 μA 200 + 50 400 + 100 800 + 200 < 10
Measuring range: 1 mA~120 A, 7-digit display, manual/automatic range shifting

 

5.3 Frequency/phase measurement

Class 0.02 specifications
Measurement type TD3100 TD3100-R
Frequency Measuring range 45 Hz~65 Hz 45 Hz~400 Hz
Minimum resolution 0.000 01 Hz 0.000 01 Hz
Measurement uncertainty (k=2) 0.005%*RD 0.005%*RD
Phase Measuring range 0~360°(I ≥ 50mA) 0~360°(I ≥ 50mA)
Minimum resolution 0.000 1° 0.000 1°
Measurement uncertainty (k=2) 45 Hz ≤ F ≤ 65 Hz 0.006° 0.006°
65 Hz < F ≤ 200 Hz -- 0.02°
200 Hz < F ≤ 400 Hz -- 0.04°
Class 0.05 specification
Measurement type TD3100 TD3100-R
Frequency Measuring range 45 Hz~65 Hz 45 Hz~400 Hz
Minimum resolution 0.000 01 Hz 0.000 01 Hz
Measurement uncertainty (k=2) 0.005%*RD 0.005%*RD
Phase Measuring range 0~360°(I ≥ 50mA) 0~360°(I ≥ 50mA)
Minimum resolution 0.000 1° 0.000 1°
Measurement uncertainty (k=2) 45 Hz ≤ F ≤ 65 Hz 0.012° 0.012°
65 Hz < F ≤ 200 Hz -- 0.04°
200 Hz < F ≤ 400 Hz -- 0.08°
 

5.4 Power / Energy Measurement

Class 0.02 specifications
Voltage range Current range Factor Measurement uncertainty at different frequencies (Hz) (k=2)
45 ≤ F ≤ 65 65 < F ≤ 200 200 < F ≤ 400
30 V ≤ U ≤ 480 V 50 mA ≤ I ≤120 A 0.5L~1~0.5C 0.02%*RD 0.04%*RD 0.08%*RD
10 mA ≤ I < 50 mA 1 0.02%*RD 0.06%*RD 0.16%*RD
0.5L~1~0.5C 0.04%*RD
5 mA ≤ I < 10 mA 1 0.04%*RD - -
0.5L~1~0.5C 0.08%*RD - -
1 mA ≤ I < 5 mA 1 0.04%*RD×5mA/I - -
Class 0.05 specifications
Voltage range Current range Factor Measurement uncertainty at different frequencies (Hz) (k=2)
45 ≤ F ≤ 65 65 < F ≤ 200 200 < F ≤ 400
30 V ≤ U ≤ 480 V 50 mA ≤ I ≤120 A 0.5L~1~0.5C 0.05%*RD 0.1%*RD 0.2%*RD
10 mA ≤ I < 50 mA 1 0.05%*RD 0.15%*RD 0.4%*RD
0.5L~1~0.5C 0.08%*RD
5 mA ≤ I < 10 mA 1 0.08%*RD - -
0.5L~1~0.5C 0.15%*RD - -
1 mA ≤ I < 5 mA 1 0.08%*RD×5mA/I - -
Power/energy measurement range: a combination of AC voltage range and AC current range
Power factor measurement range: -1.000 000... 0.000 000... 1.000 000
Standard energy pulse output: 60 kHz for high-frequency full-scale values and 6 Hz for low-frequency full-scale values
Standard energy pulse input: frequency≤ 200 kHz, voltage: 0... 3.3 V... 24 V


 

6. General Specifications

Power supply AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
Maximum power consumption 60 VA
Warm-up time 30 minutes
Temperature performance Working temperature: 5°C~45°C;
Storage temperature: -10 °C ~ 55 °C
Humidity performance Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C
Storage humidity: (20%~80%) R· H, no condensation
Altitude < 3000 m
Quality Approx. 8.5 kg
Communication interface RS232,USB,LAN
Size 400 mm(W) × 345 mm(D) × 206 mm(H) (with handle and feet)
TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
 

7. Ordering Information

TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument
Company Profile
 

TUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument

TUNKIA TD3100 High-precision Single Phase Multifunction Standard InstrumentTUNKIA TD3100 High-precision Single Phase Multifunction Standard Instrument

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier