TP1000 Surface Resistance Tester
1. Summary
TP1000 is a handheld instrument dedicated to detecting surface resistance and electrostatic leakage resistance, which can accurately measure surface resistance and electrostatic leakage of 10 3~1012 Ω The resistance value can also complete the measurement of temperature and humidity in the test environment. The measurement uncertainty of resistance measurement is 5%.
2. Features
- Resistance measurement range: 103~1012Ω
- 10 V / 100 V test voltage
- Battery-powered, replaceable battery.
- LCD color screen.
- Data storage function, support Type-C interface to export data files.
- Internal communication interface, convenient to connect to printers.
- It can be connected to an external temperature and humidity sensor to measure and record the temperature and humidity of the environment.
3. Application
☆ Test electrostatic leakage resistance and surface resistance |
|
- Under the test voltage of 10 V / 100 V, the resistance measurement range is 103~1012Ω;
- Measurement uncertainty: 5%.
|
4. Characteristics
☆ Portable design |
|
- Handheld host, large LCD color screen, rechargeable battery power supply, small size, light weight, convenient to complete the resistance test on site.
- Equipped with portable instrument case, it can store the host, heavy hammer electrode, test line, printer and other accessories.
|
☆ Connect to PC to print labels |
|
- With a Type-C interface, the device can be connected to a notebook for data transmission and operation to print test result labels.
|
☆ Temperature and humidity test |
- Built-in ambient temperature and humidity measurement function, connecting temperature and humidity probes can realize on-site environmental condition measurement.
|
|
5. Specifications
5.1 Resistance measurement
Resistance range (Ω) |
1.000 0 k< R ≤1.000 0 T |
Resolution |
0.1 Ω~ 100 MΩ |
Test voltage |
10 V / 100 V |
Optimal measurement uncertainty |
5% *RD |
Displays digits |
5-digit decimal display |
Test the electrodes |
Weight |
2.5 kg± 0.3 kg |
Contact surface diameter |
50mm~64mm |
Total resistance of conductive rubber |
< 1000 Ω |
5.2 Temperature and humidity measurement
- Relative humidity: 10% ~ 80% RH, measurement uncertainty: 5% * RD
- Temperature measurement: 0°C ~ 50°C, measurement uncertainty: 5% *RD
6. General Specifications
Power supply |
Rechargeable battery powered |
Warm-up time |
10 minutes |
Maximum power consumption |
100 VA |
Temperature performance |
Working temperature: 0°C~45°C; Storage temperature: -20 °C ~ 70 °C |
Humidity performance |
Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C Storage humidity: (20% ~ 80%) R· H, no condensation |
altitude |
< 3000 m |
Instrument quality |
Approx 0.5 kg |
Communication interface |
Type-C |