• TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
  • TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
  • TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
  • TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
  • TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
  • TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device

TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device

After-sales Service: Life Time
Warranty: 12 Months Excellent After-sales Service
Application: Electromagnetic Instrument, Electrical Calibration
Power: Electricity
LCD Display: With LCD Display
Customized: Non-Customized
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Summary
  • Features
  • Application
  • Appearance
  • Specifications
  • Company Profile
Overview

Basic Info.

Model NO.
TK6800
Three-phase ACV Output
6 V ~864 V
Three-phase ACI Output
50 mA ~ 60 A
Three-phase ACI Measurement
10 mA ~ 10 A
Accuracy
Class 0.02
Transport Package
Wooden Package
Specification
505 mm (W) × 700 mm (D) × 1200 mm (H)
Trademark
TUNKIA
Origin
China
Production Capacity
100

Product Description

 

TK6800 Transformer Comprehensive Characteristic Tester Calibration Device
 
TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
Summary

TK6800 is a calibration device dedicated to transformer testers. The calibration objects include transformer no-load loss testers, transformer capacity testers and transformer short-circuit impedance testers. Reference standard: DL/T 1256-2013 General Specification of Transformer Tester for No-load Loss and Load Loss.
 

Features
  1. Built-in three-phase voltage standard source: 6 V ~864 V
  2. Built-in three-phase current standard source: 50 mA ~ 60 A
  3. Built-in three-phase current standard meter: 10 mA ~ 10 A
  4. Voltage / current accuracy: Class 0.02
  5. Frequency and phase are adjustable; virtual power output
  6. Harmonic function: 2~63 times, adjustable content and phase
  7. Ergonomically designed console combined with removable control panel operation.
Application

 

TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
 

No-load or Load Test, Short Circuit Impedance Test, Capacity Test
TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration DeviceTK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
  1. When calibrating the no-load tester, TK6800 can switch the output transformer rated voltage or 50%~100% rated current, adjust the power output, realize the simulation of no-load and load loss, and calibrate the no-load tester.
  2. During the load test, the short-circuit impedance value can also be obtained at the same time to complete the calibration of the short-circuit impedance tester. Parameters can be used for transformer capacity calculations.
TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
3.When calibrating the capacity tester, TK6800 selects the corresponding gear according to the resistance value obtained by the short-circuit impedance test. Set the voltage output according to the calibration coefficient and measure the tester output current value. Calculate and determine the transformer capacity value through the obtained short-circuit impedance voltage and actual short-circuit impedance value, and calibrate the capacity tester.
Appearance
 Number Function Front Pane
1 Wiring panel, including no-load loss, capacity and short circuit impedance test voltage / current wiring port; TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
2 Emergency stop button, emergency stop equipment when the equipment output is abnormal;
3 Power supply switch, equipment power supply switch
4 Connecting terminal: LAN interface and RS232 interface for communication with computer;
5 The tested platform for placing the inspected equipment
6 Control the flat plate, display and operate the equipment output test;
7 Host power supply
  
Number Function Wiring Panel
1 No-load loss tester wiring terminal, including three-phase voltage / current output maximum of 864 V, 60 A. TK6800 Transformer no-load loss capacity short-circuit impedance Tester Calibration Device
2 Capacity tester terminal with three-phase voltage output 10 V and three-phase current measurement 10 A.
3 Terminal terminal of short-circuit impedance tester with maximum three-phase voltage output 864 V and AC current output maximum 60 A.
Specifications
Power Supply AC ( 220 ± 22 ) V ,( 50 ± 2 ) Hz
Warm-up time 20 Minutes
Temperature Performance Operating temperature: 15°C~35°C
Storage temperature: -20°C~50°C
Humidity Performance Working Humidity: <80% @ 30°C, <70% @ 40°C, and <40% @ 50°C
Storage humidity: (20%~80%) R·H, no condensation
Altitude < 3000 m
Communication Interface LAN ,RS232