TI5800 Sensor Power Supply and Output Tester
1. Summary
TI5800 integrates a precision voltmeter, precision ammeter, and programmable adjustable voltage source. It supplies power to a voltage or current sensor when testing it, and accurately measures the sensor's secondary output current Is or voltage Us. This instrument can be combined with a standard current source or voltage source to form a sensor testing device to test voltage or current sensors.
2. Feature
- Voltage Us Measuring Range:10 mV ~ 12 V.
- Current Is Measuring Range:1 mA ~ 1.1 A.
- Measurement Frequency: DC,AC 45 Hz~1 kHz(Optional).
- DC Measurement Uncertainty: 50 ppm.
- Built-in DC ±(5.0 V~50 V) adjustable power supply.
- Supports power consumption measurement of the tested sensor.
- Optional connection adapter to match the sensor interface of DB9.
- Optional 1~4 measurement channels.
3. Application
☆ Sensor power supply and measurement of secondary signals |
Sensor Secondary Signal Measurement Module
- Built-in standard ammeter and standard voltmeter can accurately measure the secondary output Is or Us of the sensor.
- It can be used with standard current sources or voltage source groups to test the proportional error of voltage or current sensors.
Sensor Power Supply Module
- Built-in DC ±(5 V ~ 50 V) adjustable power supply can test the power supply impact of the sensor under test.
- A standard ammeter is connected in series in the power supply module loop. It can measure the no-load or full-load power consumption of the sensor being tested.
|
4. Specification
4.1 DC Voltage/Current Measurement
Current Range |
10 mA,100 mA,1 A,manual/automatic range switching. |
± (1 mA ~ 1.1 A) |
Voltage Range |
100 mV,1 V,10 V,manual/automatic range switching. |
± (10 mV ~ 12 V) |
Measurement Uncertainty(k=2) |
0.003%*RD + 0.002%*RG [1] |
Temperature Coefficient@ (0°C~40°C) |
2 ppm*RD/°C |
Display |
7-digit decimal |
Note |
[1]: RD is the reading value, RG is the range value, the same below. |
4.2 AC Voltage/Current Measurement (Optional)
Current Range |
10 mA,100 mA,1 A,manual/automatic range switching. |
1 mA ~ 1.1 A |
Voltage Range |
100 mV,1 V,10 V,manual/automatic range switching. |
10 mV ~ 12 V |
Measurement Frequency |
45 Hz ~ 1 kHz |
Measurement Uncertainty(k=2) |
0.006%*RD + 0.004%*RG |
Temperature Coefficient@ (0°C~40°C) |
5 ppm*RD/°C |
Display |
7-digit decimal |
5. General Specification
Power Supply |
AC ( 220 ± 22 ) V,(50±2) Hz |
Maximum Power Consumption |
100 VA |
Warm-up Time |
2 times the last predicted warm-up time, up to 30 minutes. |
Working Environment |
Temperature: 0°C ~ 40°C Humidity: 20%R·H ~ 80%R·H,no condensation. Others: No electromagnetic field interference. |
Storage Environment |
Temperature: -20°C ~ 70°C Humidity: <95%R·H,no condensation. |
Altitude |
< 3000 m |
Communication Interface |
RS232×1 |
6. Ordering Information
Company Profile